• Title/Summary/Keyword: Chemical cleaning agents

Search Result 62, Processing Time 0.029 seconds

A Study on the Design Concept for NBC Clothing (화생방보호의 설계 개념 연구)

  • Kang, Jae-Sung;Seo, Hyeon-Kwan;Park, Hyen-Bae;Ryu, Sam-Gon;Park, Sang-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.193-200
    • /
    • 2012
  • The selection factors of the protective clothing against the NBC agents are the protection(chemical, biological, TIMs), duration, weight/comfort, dexterity/mobility, size, visibility, cleaning and unit cost, etc. To develop the NBC protective clothing, we should need to review about the design concepts of the protective materials(shell and liner fabric) and form. This paper identify an important factors for the protective materials and form, and presents design strategies for important factors based on the evaluation results of the materials and the form.

Comparative study on the efficiency of pesticide residue removal in foods (Perilla Leaves, Strawberries, Apples)

  • Seung-Woon Myung
    • Analytical Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • In agricultural households cultivating vegetables and fruits, the use of various pesticides to protect crops from diseases and pests or to control weeds is widely practiced enhancing quality and productivity. However, pesticides can pose a threat to consumer health by remaining on the food surface or migrating into the food interior. Households commonly peel off skins, wash with water, or use chemical methods to remove foreign substances including residual pesticides on the food surface. In this study, we measured the washing rate by comparing the pesticide concentrations before and after washing in the leafy vegetable perilla leaves and the fruits strawberries and apples, which were intentionally exposed to pesticides. We compared washing rates using tap water, a baking soda solution, and a commercially available food-specific cleaning solution. The target pesticides for analysis were azoxystrobin, bifenthrin, boscalid, difenoconazole, flubendiamide, and indoxacarb, and the residual pesticide analysis was performed using GC-MS/MS or LC-MS/MS. The removal rates of pesticides were highest with the food-specific cleaner, followed by baking soda and tap water in order.

Preparation of Water-Resistant Hydrophilic Coating Solutions for PET film (내수성이 우수한 PET 필름용 친수성 코팅액의 제조)

  • Lee, Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.584-594
    • /
    • 2014
  • To increase of surface hydrophilicity of polymeric thin films is an important approaching technique for introduction of self-cleaning and/or antifogging properties on the surfaces of those films. In general, hydrophilic surface can be produced by coating non ionic surfactants or by increasing surface energy. Various non-ionic surfactants, such as Tween, Span, and PEG-PPG block copolymers were selected for our experiments, because they are cheap and well soluble in toluene system as well as they contain several reactive hydroxy fuctional groups with coupling agents. Blending conditions influence the PET film surface hydrophilicities. However, the introduction of only these surfactants on the surface of PET films did not show the high durability of hydrophilic properties after washing with water. To improve the durability two types of coupling agents such as epoxide and diisocyanate were adopted. Contact angle of water on hydrophilically coated PET film surface with 6 wt% of isophrone diisocyanate(IPDI) containing coating solution was reached to $8.7^{\circ}$, which was an indirect evidence for very high surface hydrophilicity. A light(500 nm of wavelength) transmittance value of coated PET film was changed only from 87% to 85% with keeping a good transparent property. This film can be usable for self-cleaning film industries.

Chemical Cleaning of Iron Stains on Ceramics (화학세척제를 이용한 도자기의 철산화물 제거 특성 연구)

  • Park, Dae-Woo;Jang, Sung-Yoon;Nam, Byeong-Jik;Ham, Chul-Hee;Lim, Seong-Tae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.345-356
    • /
    • 2011
  • To remove metal stains of the ceramics, chemical cleaning is essential case by case. This study investigated the removal characteristics of iron stains by oxalic acid and citric acid including their application methods of soaking and poultice. The soaking method in cleaning agents showed removal process by color difference and released iron contents from iron stains on ceramics. Iron stains were removed successfully from ceramics, which soaked in oxalic acid for 60 hours. However, it is recommendable to soak in 0.25M oxalic acid for one to three hours because most iron stains were disappeared in 3 hours soaking. Citric acid is less effective than oxalic acid in removing iron stains because of heavy molecular weight and low acidity. Poultices (bentonite, sepiolite, activated carbon fiber and celite) with oxalic acid were applied on contaminated ceramics. After ten hours, iron stains on ceramics were removed successfully by poultice. Among them, bentonite and sepiolite have better application. Therefore, sepiolite with 0.25M oxalic acid was applied on the iron stains of whiteware and celadon from Ma Island, and then stains were removed. However, it is judged that the application methods can be varied according to the form and depth of contaminant. In addition, the residues of poultice on the ceramics will be considered for preventing contamination.

Long Term Evaluation of UF Membrane process using River-bed Water (복류수를 이용한 한외여과공정의 장기운전 평가)

  • Kim, Chung H.;Lim, Jae L.;Kang, Suk H.;Kim, Su H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

Role of Glutathione Conjugation in 1-Bromobutane-induced Immunotoxicity in Mice

  • Lee, Sang-Kyu;Lee, Dong-Ju;Jeon, Tae-Won;Ko, Gyu-Sub;Yoo, Se-Hyun;Ha, Hyun-Woo;Kang, Mi-Jeong;Kang, Won-Ku;Kim, Sang-Kyum;Jeong, Tae-Cheon
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.101-108
    • /
    • 2010
  • Halogenated organic compounds, such as 1-bromobutane (1-BB), have been used as cleaning agents, agents for chemical syntheses or extraction solvents in workplace. In the present study, immunotoxic effects of 1-BB and its conjugation with glutathione (GSH) were investigated in female BALB/c mice. Animals were treated orally with 1-BB at 375, 750 and 1500 mg/kg in corn oil once for dose response or treated orally with 1-BB at 1500 mg/kg for 6, 12, 24 and 48 hr for time course. S-Butyl GSH was identified in spleen by liquid chromatography-electrospray ionization tandem mass spectrometry. Splenic GSH levels were significantly reduced by single treatment with 1-BB. S-Butyl GSH conjugates were detected in spleen from 6 hr after treatment. Oral 1-BB significantly suppressed the antibody response to a T-dependent antigen and the production of splenic intracellular interlukin-2 in response to Con A. Our present results suggest that 1-BB could cause immunotoxicity as well as reduction of splenic GSH content, due to the formation of GSH conjugates in mice. The present results would be useful to understand molecular toxic mechanism of low molecular weight haloalkanes and to develop biological markers for exposure to haloalkanes.

A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers (R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구)

  • JUNG, DA-WOON;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

Fine Dust Adsorption of Cement Matrix Using Sepiolite (세피올라이트를 활용한 시멘트 경화체의 미세먼지 흡착 특성 )

  • Jeon, Eun-Yeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.71-72
    • /
    • 2023
  • As industrialization and urbanization accelerate, environmental issues have moved from local concerns to global issues. Among them, air pollution is the most important issue. Modern people spend more than 88% of their day indoors, but the concentration of fine dust and pollutants flowing indoors is increasing. The indoor environment has its own complexity, and various substances used indoors, such as building materials, furniture, electronics, and cleaning agents, emit chemical substances and cause various diseases. Therefore, when selecting building materials and interior finishing materials, the pollutant emission and adsorption capacity must be greatly considered. These considerations will ensure the construction of a sustainable future environment and a healthy life within that environment. Therefore, in order to reduce the generation of indoor air pollutants, this study aims to examine the fine dust adsorption properties of cement hardening materials using sepiolite, which has a porous structure and high absorption power among clay minerals. As a result of the experiment, it was found that the concentration of fine dust decreased as the addition rate of sepiolite increased. It is believed that the fine dust concentration was reduced due to the high porosity due to the microfibrous structure and large specific surface area of sepiolite, which has a porous structure among clay minerals. It is believed that these experimental results can be used as basic research for future use of sepiolite as a construction material.

  • PDF

Characteristics of Permeation and Fouling of UF/MF Hollow Fiber Membranes for Drinking Water Treatment (정수처리 적용을 위한 UF/MF 중공사막의 투과성능과 오염현상)

  • 이주형;김정학;이용택
    • Membrane Journal
    • /
    • v.10 no.2
    • /
    • pp.75-82
    • /
    • 2000
  • This study, which was tarried out to investigate the characteristics of permeation rates and fouling phenomena in drinking-water treating processes with MF membrane, showed that pressure drop was dependent on the length of membrane module and operating pressure; the pressure drop increased with the length of membrane module and operating pressure, operation at a relatively low pressure(0.5kg/$cm^2$) is better than that at a relatively (2.0kg/$cm^2$), since high operating pressure accelerates the clogging. In case of out-in permeation type, almost same flux was obtained after a certain operating time regardless of membrane length and operating pressure. In order to understand, the microbial fouling, chemical cleaning was carried out to the forced contaminated hollow-fiber membrane with chemicals($H_2O_2$, NaOCl, and NaOH). Chemical cleanings with $H_2O_2$and NaOCl, which are oxidizing agents, are better for sterilizing and desorbing the microbes than those with NaOH.

  • PDF

Reaction Path Modeling of Granitic Cultural Properties and Its Implication for Preservation (화강암질 석조문화재의 풍화반응경로 특성과 보존에 대한 제언)

  • Park Maeng-Eon;Sung Kyu-Youl
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2005
  • Dissolution rate of minerals may differ from climates configuration, but weathering rate of feldspars is generally proved to be relatively higher The result of geochemical reaction modeling indicates the acid water of pH 4.5 excluding any other variables, was 2.3 times higher than that in ordinary rain of pH 5.7. This result proved that pH is very important factor in preservation of granite cultural properties. To prevent the weathering of stone cultural properties, weathering characteristics of stones should be studied first and constitution of dry environments, using water repellent or oil coating, isolating water which cause chemical weathering reaction like hydration and oxidization should be considered. Considering the long-term reactions between granite and rain, selection of materials, which can bring neutralization and non-oxidization conditions, are very important in using cleaning agents and biological controls.