• Title/Summary/Keyword: Chemical cleaning agents

Search Result 62, Processing Time 0.032 seconds

A Study on the Preparation of Alkaline Cleaning Agents for Steel (철강용 알칼리세정제의 제조에 관한 연구)

  • Keun, Jang-Hyoun;Hahm, Hyun-Sik;Park, Hong-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.35-40
    • /
    • 1993
  • Alkaline cleaning agent(ACA) was prepared by blending of POE(4)octadecylmine(S-204), $Na_2CO_3$, sodium orthosilicate(Na-OSi). Tetronix T-701(T-701), and MJU-100A. The physical properties of ACA tested with steel specimen showed the following results. The cleaning powers of ACA-6(S-204 80g/$Na_2CO_3$, 160g/Na-OSi, 80g/T-701, 60g/MJU-100A, 20g mixture) for press-rust preventing oil was 98% and 99% degreasing at 2wt%, $70^{\circ}C$ and $90^{\circ}C$, respectively : for quenching oil, the cleaning power of ACA-6 was 95% degreasing at 2wt% and $70^{\circ}C$. From these results, it was ascertained that ACA-6 exhibited a good cleaning power. Foam heights measured immediately after foaming by Ross & Miles method and Ross & Clark method at 3wt%. $60^{\circ}C$ were 17mm and 40mm, respectively. As the result, ACA-6 was proved a good low foaming cleaning agent.

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Effects of Ultrasonic Cleaning and Chemical Pre-treatment on the Characteristics of Fast-stabilized Rayon Fabrics (빠르게 안정화된 레이온직물의 특성에 미치는 초음파세척 및 화학전처리 영향)

  • Cho, Chae Wook;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.14 no.3
    • /
    • pp.146-159
    • /
    • 2013
  • In the present study, stabilized rayon fabrics were prepared from fast isothermal stabilization processes, which were carried out within four minutes at $350^{\circ}C$. The effects of ultrasonic cleaning and chemical pre-treatment on the chemical composition, physical characteristics, X-ray diffraction pattern, thermal stability and shape of the stabilized rayon fabrics were investigated extensively. In order to reduce the weight loss and thermal shrinkage of rayon fabrics occurring during the stabilization process, ultrasonic cleaning was first conducted and then chemical pre-treatments using $NH_4Cl$, $Na_3PO_4$, $H_3PO_4$, and $ZnCl_2$ were performed, respectively. The results indicated that both ultrasonic cleaning and chemical pre-treatment influenced the weight loss, thermal shrinkage, microstructure, carbon content, thermal stability and fabric shape of stabilized rayon fabrics. Also the results depended on the fast-stabilization time and the type of chemical pre-treatment agents used.

Development of Environmental-friendly Cleaning Agents Utilizing Organic Acids for Removal of Scale on the Wall of Cleaning Beds and Distribution Reservoirs in the Waterworks (유기산을 이용한 상수도 정수장 및 배수지 벽면 스케일 세척용 친환경 세정제 개발)

  • Lee, Jae-Ryoung;Yoon, Hee-Keun;Bae, Jae-Heum;Shin, Hyun-Duk
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.272-279
    • /
    • 2012
  • In this study, an environmental-friendly cleaning agent utilizing organic acids and various additives has been developed and applied to the field for removal of scale deposited on the cleaning beds or distribution reservoirs of the waterworks. As an analytical result of scale on the cleaning beds, we found that it consists of mainly metallic oxides such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, and MnO. Malic acid, malonic acid, and citric acid showed relatively better solvency on $Al_2O_3$, $Fe_2O_3$, and MnO except $SiO_2$ among various organic acids. Mixed organic acid solutions of malic acid, malonic acid, and citric acid were prepared with certain weight ratios and their solvencies on mixed metal oxides of $Al_2O_3$, $Fe_2O_3$, and MnO were investigated. The experimental results showed that an 10% mixed organic acid solution prepared with weight ratio of malic acid : malonic acid : citric acid = 6 : 2 : 2 were found to have best scale solvency power of about 29%. The formulated cleaning agents with a small amount of nonionic surfactant showed much better solvency on mixed oxides than mixed organic solution alone. Especially, the formulated cleaning agent with 0.2 wt% LA-7 surfactant appeared to have best scale removal efficiency of about 35%. However, the formulated cleaning agent with disinfectants such as NaClO, $H_2O_2$ and $Ca(ClO)_2$ showed poor solvency on mixed oxides. It is inferred that surfactants are able to improve scale removal efficiency due to their capability of emulsification, and disinfectants cause to degrade scale solvency in water because of their oxidation. Based on these basic experimental results, formulated cleaning agents have been prepared with mixed organic acid solution, nonionic surfactants, and disinfectants and successfully applied to removal of scales on the cleaning beds and distribution reservoir at city D waterworks.

A Study of Cleaning on the Biofilm of Stone Cultural Properties (석조문화재 생물막 제거 및 처리방안 연구)

  • Chung, Yong-Jae;Seo, Min-Seok;Lee, Kyu-Shik;Hwang, Jin-Ju
    • 보존과학연구
    • /
    • s.26
    • /
    • pp.5-25
    • /
    • 2005
  • A consideration number of investigation have begun to elucidate the essential role biological agents play in the deterioration of stone. What is becoming clear is that many factors affect the durability of stone. Physical, chemical, and biological agentsact in co-association, ranging from synergistic to antagonistic, to deteriorate stone. Biodeterioration has usually been considered to be a degradation process following the initial deterioration effects of inorganic agents, especially objects of cultural value such as pagoda, stature of Buddha etc. These agents were thought to condition stone surfaces for microbial contamination due to structural changes and enrichment of inorganic organic nutrient substrates. This report concentrates on the action of biodeteriogens from bacteria to algae and higher plants. Preventive and remedial methods are surveyed, as are a selection of chemical treatments.

  • PDF

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

Stability Evaluation of Cleaning Agent for Ceramics (토기 및 도자기 유물에 사용되는 보존처리용 세척제의 안정성 평가)

  • Park, Daw-Woo;Kang, Hyun-Mi;Nam, Byeong-Jik;Jang, Sung-Yoon
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.451-464
    • /
    • 2009
  • To do conservation for ceramics, sometimes it needs to clean the ceramics chemically to remove stains on the ceramics, which should be performed with caution. This study will provide quantitative data about the extraction characteristics of major elements from ceramics through the soaking test to evaluate the stability of ceramic cleaning agents. As soft textured pottery(fired at $700^{\circ}C$) had high absorption, it showed higher extraction characteristics in short soaking time. Especially the strong acid among chemical cleaning agents caused the expoliation and the color change on the surface of soft textured pottery. But these color change had no effect on the physical characteristics of soft textured pottery. The hard textured pottery(fired at $1,000^{\circ}C$) is relatively stable in the cleaning agent because it is ascertained the extraction of that was not enough and also it had little chromatic and physical change by strong acid. Porcelains(Celadon, Whiteware and Puncheong ware) was safer than the soft textured pottery due to their low extraction. But it should take precautions to clean the porcelains with lots of cracklewares such like Puncheong ware chemically in connection with the extraction characteristics and their cracklewares.

  • PDF

Alteration of Physical and chemical Characteristics of Waterlogged Archaeological Woods After Cleaning (세척 후 수침고목재의 물리.화학적 특성 변화)

  • Cha, Mi-Young;Lee, Kwang-Ho;Kim, Yoon-Soo
    • Journal of Conservation Science
    • /
    • v.19
    • /
    • pp.19-30
    • /
    • 2006
  • Alteration of physical and chemical characteristics and the effect of removal of mineral substances in waterlogged archaeological woods by different cleaning processes were examined using oak wood(Quercus spp.) that was excavated from wetland near Gwangju, Korea. Cleaning methods employed in the present work were (1) tools, (2) deaeration, (3) EDTA and (4) ultrasonic cleaning, which are being currently applied in the field of preservation treatment. Cleaning process were performed independently or continuously. Composition of mineral substances in the waterlogged archaeological wood was almost same as the that of soil in which waterlogged archaeological woods were buried. In case of independent cleaning, tools cleaning efficiently removed the mineral substances on surface. Surface color become brighter after cleaning with EDTA. In contrast, deaeration and ultrasonic cleaning did not show any significant removal of mineral substances. In continuous cleaning process, tool cleaning as the first step treatment showed the same effect as shown in independent cleaning. Although deaeration as the second step cleaning did not remove the mineral substances, it could be assumed to contribute the infiltration of dimensional agents by homogenization of wood. EDTA treatment (the third step cleaning) removed the iron(Fe) and increased the whiteness of wood color. The ultrasonic treatment (the fourth step cleaning) removed the sodium(Na) remained after EDTA treatment and the fine mineral substances.

  • PDF

A novel method of surface modification to polysulfone ultrafiltration membrane by preadsorption of citric acid or sodium bisulfite

  • Wei, Xinyu;Wang, Zhi;Wang, Jixiao;Wang, Shichang
    • Membrane and Water Treatment
    • /
    • v.3 no.1
    • /
    • pp.35-49
    • /
    • 2012
  • In membrane processes, various agents are used to enhance, protect, and recover membrane performance. Applying these agents in membrane modification could potentially be considered as a simple method to improve membrane performance without additional process. Citric acid (CI) and sodium bisulfite (SB) are two chemicals that are widely used in membrane feed water pretreatment and cleaning processes. In this work, preadsorptions of CI and SB were developed as simple methods for polysulfone ultrafiltration membrane modification. It was found that hydrogen bonding and Van Der Waals attraction could be responsible for the adsorptions of CI and SB onto membranes, respectively. After modification with CI or SB, the membrane surfaces became more hydrophilic. Membrane permeability improved when modified by SB while decreased a little when modified by CI. The modified membranes had an increase in PEG and BSA rejections and better antifouling properties with higher flux recovery ratios during filtration of a complex pharmaceutical wastewater. Moreover, membrane chlorine tolerance was elevated after modification with either agent, as shown by the mechanical property measurements.