• 제목/요약/키워드: Chemical Supply System

검색결과 283건 처리시간 0.023초

에너지 절약형 공기압 시스템 특성에 관한 연구 (A Study on the Energy Saving Type Pneumatic System Characteristics)

  • 김형의;김동수;강보식;성백주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.91-98
    • /
    • 1995
  • Recently, improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, pneumatic cylinder is applied to feeding work of workpiece. jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, the experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure($4.5kg_f/cm^2$) of compressed air goes into the rodless chamber 1 to drive the piston rod forward which is named working stage. The supply pressure ($2kg_f/cm^2$) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, the research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

화학플랜트에서의 릴리프밸브 설계에 관한 고찰 (A Study on Engineering Design IT Installation of Thermal Relief Valve in a Chemical Plant)

  • 차순철;황순용;장서일
    • 대한안전경영과학회지
    • /
    • 제8권4호
    • /
    • pp.39-51
    • /
    • 2006
  • Based on the practical process engineering design and commissioning and startup operation experiences focused on chemical process safety, the comprehensive review of engineering design and installation of the thermal relief valve with its surrounding facility in a chemical plant piping system is provided to enhance the better understanding of the piping system of characteristics of thermal relief valve which is comprised of the theoretical approach, correlation in terms of temperature and pressure increase caused by external heat supply in a piping system, consideration of thermal relief valve engineering design, pressure relieving system of serial thermal relief valves and exception of their installation. It is earnestly suggested that following topic should be implemented during thermal relief valve engineering design, installation and normal operation as well.

화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구 (A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor)

  • 변윤섭
    • 한국가스학회지
    • /
    • 제24권4호
    • /
    • pp.32-38
    • /
    • 2020
  • 화학반응기에 발생한 화재·폭발 사고사례를 기반으로 화학반응기에 설치되어 있는 예방조치의 문제점을 분석하였다. 화학반응기는 다품종의 화학제품을 생산하며, 반응폭주시 급격히 상승하는 압력을 해소하기 위해 파열판을 설치하고 파열판의 기능을 유지하기 위해 배출물질을 대기로 배출하도록 허용하고 있어 화재·폭발사고가 발생하였다. 이를 개선하기 위한 방안으로 안전건전성수준(SIL3)을 기반으로 한 안전계장시스템(SIS)을 화학반응기의 예방조치로 적용하였다. 화학반응기의 원재료를 적하하는 배관에 긴급차단밸브를 직렬로 2개 설치하여 반응폭주시 긴급차단밸브 2개 중 1개만 작동하여도 원재료 공급을 차단할 수 있도록 하고, 반응응제제 공급배관에는 자동 ON/OFF 밸브를 병렬로 설치하여 반응폭주시 1개의 밸브만 열려도 반응억제제가 투입될 수 있게 하였다.

Connection of spectral pattern of carbohydrate molecular structure to alteration of nutritional properties of coffee by-products after fermentation

  • Samadi;Xin Feng;Luciana Prates;Siti Wajizah;Zulfahrizal;Agus Arip Munawar;Weixian Zhang;Peiqiang Yu
    • Animal Bioscience
    • /
    • 제37권8호
    • /
    • pp.1398-1407
    • /
    • 2024
  • Objective: The objective of this study was to determine internal structure spectral profile of by-products from coffee processing that were affected by added-microorganism fermentation duration in relation to truly absorbed feed nutrient supply in ruminant system. Methods: The by-products from coffee processing were fermented using commercial fermentation product, consisting of various microorganisms: for 0 (control), 7, 14, 21, and 28 days. In this study, carbohydrate-related spectral profiles of coffee by-products were correlated with their chemical and nutritional properties (chemical composition, total digestible nutrient, bioenergy values, carbohydrate sub-fractions and predicted degradation and digestion parameters as well as milk value of feed). The vibrational spectra of coffee by-products samples after fermentation for 0 (control), 7, 14, 21, and 28 days were determined using a JASCO FT/IR-4200 spectroscopy coupled with accessory of attenuated total reflectance (ATR). The molecular spectral analyses with univariate approach were conducted with the OMNIC 7.3 software. Results: Molecular spectral analysis parameters in fermented and non-fermented by-products from coffee processing included structural carbohydrate, cellulosic compounds, non-structural carbohydrates, lignin compound, CH-bending, structural carbohydrate peak1, structural carbohydrate peak2, structural carbohydrate peak3, hemicellulosic compound, non-structural carbohydrate peak1, non-structural carbohydrate peak2, non-structural carbohydrate peak3. The study results show that added-microorganism fermentation induced chemical and nutritional changes of coffee by-products including carbohydrate chemical composition profiles, bioenergy value, feed milk value, carbohydrate subfractions, estimated degradable and undegradable fractions in the rumen, and intestinal digested nutrient supply in ruminant system. Conclusion: In conclusion, carbohydrate nutrition value changes by added-microorganism fermentation duration were in an agreement with the change of their spectral profile in the coffee by-products. The studies show that the vibrational ATR-FT/IR spectroscopic technique could be applied as a rapid analytical tool to evaluate fermented by-products and connect with truly digestible carbohydrate supply in ruminant system.

A Study on the Tolerance Band of Voltage Drop during Motor Startup for Refineries and Chemical Plants with Isolated Power Systems

  • Shin, Ho-Jeon;Cho, Man-Young;Chun, Hong-Il;Kim, Jin-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.486-493
    • /
    • 2017
  • Refineries and chemical plants with isolated power systems that have a limited power supply are more susceptible to voltage changes from disturbances compared to power systems connected with a power company. Furthermore, most loads in such cases are induction motor loads, and therefore, transient voltage characteristics when starting a high-capacity motor must be examined. In general, high-capacity motors are customized appropriately to the load performance curve by the manufacturer during the construction of an industrial plant. Subsequently, when complying with the voltage drop permitted by international standards during the design process, power supply equipment such as transformers and generators is overdesigned. Therefore, a novel analysis is necessary on standards for startup and constraint voltage drops, as well as on identifying the voltage drop limitations for starting high-capacity motors in refineries and chemical plants with isolated power systems. In this study, field tests on an industrial plant were conducted, and simulations modeled under conditions identical to those of the field test system were performed using the general-purpose program ETAP in order to compare the results.

배관계에서 열팽창을 고려한 열팽창매출변 및 주변설비의 설계와 설치에 관한 고찰 (The Review of Design and Installation of the Thermal Relief Valve with It's Surrounding Facility in a Chemical Plant Piping System)

  • 차순철;김영배
    • 기술사
    • /
    • 제30권3호
    • /
    • pp.104-114
    • /
    • 1997
  • Throughout the practical process engineering design and commissioning 8E startup experiences focused on chemical process safety, the review of design and installation of the thermal relief valve with its surrounding facility in a chemical plant piping system is made to help the better understanding of the piping system of characteristics of thermal relief valve which Is consisting of theoretical approach, correlation in terms of temperature and pressure increase caused by external heat supply in a piping system, consideration of thermal relief valve design, pressure relieving system of serial thermal relief valves and exception of their installation. It is earnestly recommended that following topic should be implemented during thermal relief valve design, installation and normal operation as well.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I) (A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I))

  • 김철수;김진현
    • Journal of Biosystems Engineering
    • /
    • 제19권2호
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

고온로를 이용한 매연발생장치 (Soot Generation System Utilizing High-Temperature Furnace)

  • 조상환;박선호;남연우;최유열;이원남
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.55-58
    • /
    • 2013
  • A new soot particle generation system has been developed and tested. The soot generation system consists of two sections, a fuel supply and a soot production. In the fuel supply module, either liquid fuel precisely controlled by a syringe pump is mixed with preheated carrier gas and rapidly evaporated or gaseous fuel controlled by a MFC is diluted with dilution gas. The soot production module contains a heater that can raise the gas/fuel temperature up to $1400^{\circ}C$. The physical and chemical properties of produced soot particles depend on the type and concentration of fuel, the residence time, and temperature in the soot production section. The soot generation system will be utilized to produce well-defined soot particles for soot studies such as the evaluation of experimental sampling and analysis processes for the quantitative assessment of PM and BC from ships and the adverse health effects on pulmonary and cardiovascular systems of human body.

  • PDF

도시가스 용 바이오 가스 정제 시스템 개발 (Development of Biogas Purification System for City Gas Supply)

  • 이현진;고상욱;이인동;정인희;고재욱
    • 한국가스학회지
    • /
    • 제23권2호
    • /
    • pp.61-67
    • /
    • 2019
  • 우리나라는 천연가스 수입국으로 2018년 미국이 수출한 물량의 20%를 수입할 정도로 많은 양을 수입하고 있다. 이에 가스 수요를 만족시키며, 기후변화 대응에 효과적으로 대응할 수 있는 바이오가스는 대체제가 될 수 있을 것으로 생각된다. 그러나 바이오가스의 생산량의 20%만이 판매되고 있고, 이 역시 효율이 좋지 못해 활용하기 어려운 실정이다. 본 연구에서는 바이오가스를 도시가스로 공급 할 수 있는 최적의 정제 시스템을 개발을 목적으로 하였다. 시스템 선정을 위한 바이오가스에 대한 분석, 시스템 설계를 위한 사례 발굴, 시나리오 구성, 비용편익 툴을 개발하고 사례 적용하여 최적의 시스템을 개발하고자 하였다.

Development of models for the prediction of electric power supply-demand and the optimal operation of power plants at iron and steel works

  • Lee, Dae-Sung;Yang, Dae-Ryook;Lee, In-Beum;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.106-111
    • /
    • 1992
  • In order to achieve stable and efficient use of energy at iron and steel works, a model for the prediction of supply and demand of electric power system is developed on the basis of the information on operation and particular patterns of electric power consumption. The optimal amount of electric power to be purchased and the optimal fuel allocation for the in-house electric power plants are also obtained by a mixed-integer linear programming(MILP) and a nonlinear programming (NLP) solutions, respectively. The validity and the effectiveness of the proposed model are investigated by several illustrative examples. The simulation results show the satisfactory energy saving by the optimal solution obtained through this research.

  • PDF