• 제목/요약/키워드: Chemical Detection

검색결과 1,715건 처리시간 0.027초

Multiplexed DNA Detection with DNA-Functionalized Silver and Silver/Gold Nanoparticle Superstructure Probes

  • Kim, Ji-Young;Lee, Jae-Seung
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.221-226
    • /
    • 2012
  • DNA-functionalized silver and silver/gold bimetallic nanoparticle superstructure probes with controllable sizes and optical properties are synthesized using monothiol DNA and dithiothreitol. The superstructures exhibit a very narrow size distribution, which can be easily controlled by balancing the ratio of dithiothreitol and DNA. These superstructures assemble reversibly in a highly cooperative manner, and are SERS active. Multiplexed colorimetric detection of DNA targets using these superstructure probes has been demonstrated to identify three different DNA target sequences that are associated with three lethal diseases, respectively.

Development of an Enzyme-Linked Immunosorbent Assay for the Organophosphorus Insecticide Cyanophos

  • Park, Jae-Hyun;Park, Won-Chul;Kim, Yoo-Jung;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권4호
    • /
    • pp.605-609
    • /
    • 2002
  • A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of organophosphorus insecticide cyanophos. An analogue (hapten) of cyanophos was synthesized and was coupled to BSA to produce polyclonal antibodi es from rabbits. The antisera were screened against another hapten coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 310 ng/mL with the detection limit of 20 ng/mL. The antibodies showed negligible cross-reactivities with other organophosphorus pesticides except for parathion-methyl, which makes the assay suitable for the selective detection of cyanophos.

Development of an ELISA for the Organophosphorus Insecticide Isofenphos

  • Park, Han-Jin;Park, Won-Chul;Jung, Tae-Owan;Rha, Choon-Sup;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권4호
    • /
    • pp.599-603
    • /
    • 2002
  • A selective enzyme-linked immunosorbent assay (ELISA) for the insecticide isofenphos was developed. Three different analogues (haptens) of isofenphos were synthesized and were coupled to carrier proteins through the pesticide thiophosphate group t o use as immunogens or coating antigens. Rabbits were immunized with one of the haptens coupled to BSA for production of polyclonal antibodies and the sera were screened against each of the other two haptens coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 96 ng/mL with the detection limit of 2 ng/mL. The antibodies showed negligible cross-reactivity with other organophosphorus pesticides and the phenol metabolite of isofenphos, which makes the developed assay suitable for the selective detection of isofenphos. An antibody-coated ELISA was also developed, which showed an I50 of 580 ng/mL with a detection limit of 70 ng/mL.

Detection of Nitroaromatic Compounds Based on Fluorescent Silafluorene Chemosensors

  • 김범석
    • 통합자연과학논문집
    • /
    • 제3권1호
    • /
    • pp.19-23
    • /
    • 2010
  • A simple and rapid method is described for detecting nitroaromatic explosives in air or seawater with the use of photoluminescent organosilicon compounds. The synthesis, spectroscopic characterization, and fluorescence quenching efficiency of silafluorenes are reported. Silafluorenes were synthesized from the reduction of dilithiobiphenyl with dichlorosilanes. Two silafluorenes were used for the detection of nitroaromatic compounds. Detection of nitroaromatic molecules, such as 2,4-dinitrotoluene (DNT), 2,4,6-trinitrotoluene (TNT), and picric acid (PA), has been explored. A linear Stern-Volmer relationship was observed for the first three analytes. Fluorescence spectra of silafluorenes obtained in either toluene solutions or thin films displayed no shift in the maximum of the emission wavelength. The photoluminescence quenching occurs by a static mechanism.

Development of Novel Method for the Detection of Microcystin Using Chemiluminescence Immunochromatography

  • Pyo, Dong-Jin;Yoo, Ji-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.149-152
    • /
    • 2011
  • A new chemiluminescence immunochromatographic analysis system with high sensitivity and high reproducibility was developed for the determination of microcystins (MCs) in water. Horse radish peroxidase (HRP) labeled microcystin monoclonal antibody was used for the sensitive chemiluminescence detection. The chemiluminescence immunochromatographic analysis system was composed of microcystin LR (MCLR)-monoclonal antibody (mAb)-Horse Radish Peroxidase (HRP) conjugate, MCLR-BSA conjugate, luminol, hydrogen peroxide mixture solution, an immunochromatographic assay strip and luminometer. To detect the concentration of microcystins in water, we utilized one spot analysis of the strip instead of flow type analysis. We could detect the microcystins in water at a concentration as low as 9.45 pg/mL with the chemiluminescence (CL) detection.

pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발 (Development of Microfluidic Polydiacetylene Sensor Chip for pH detection)

  • 황현진;송시몬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF

A Direct Detection of $CO_2$ in Sealed-off $CO_2$ Discharge Tube by Optoacoustic Effect

  • Kim Sung-Ho;Choi Joong-Gill;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.23-25
    • /
    • 1994
  • A simple analytical method that allows direct monitoring of small amount of CO$_2$ in a CO$_2$ discharge tube which utilizes the optoacoustic detection technique is described. The dependence of the optoacoustic signal on the mole fraction of CO$_2$ was shown that the system responded linearly to the amount of CO$_2$ present in the miniature discharge cavity equipped with Cu electrodes. It was also found that fraction of dissociated CO$_2$ varied from 14 to 37% of the initial concentration which depended on the current and the pressure in the tube. This simple and easy detection method has proven to possess the practical advantages over the conventional systems for the study of CO$_2$ laser electrodes.

Preconcentration and Detection of Herbicides in Water by Using the On-line SPE-HPLC System and Photochemical Reaction

  • 이승호;이성광;박영훈;김현주;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권10호
    • /
    • pp.1165-1171
    • /
    • 1999
  • The analysis of trace herbicides using the on-line SPE-HPLC system and a photochemical reaction was studied. 18 compounds of herbicides including eight triazines, six phenoxy acids and esters, and four other herbicides were examined. The on-line SPE-HPLC system developed for selection of eluting solvent improved chromatographic efficiency. The recoveries of herbicides were higher than 77%. With 100 mL tap water samples, the detection limits for all analytes were in the 0.1-2.3×10-10 M range. Detection was done by a UV or fluorescence spectrometer after photochemical reaction at the end of the column with 2W or 450W mercury lamp. Without a photochemical reaction, all compounds responded to 230 nm UV detector, but phenoxy acids and esters were weakly detected. However, with a photochemical reaction, these compounds were selectively detected at 320 nm wavelength of UV absorption and 400 nm emission of the fluorescence detectors. This method can be used for the analysis of environmental water containing herbicides at trace levels.

Fault Detection in the Two-for-One Twister

  • Park, Ho-Cheol;Koo, Doe-Gyoon;Lee, Jie-Tae;Cho, Hyun-Ju;Han, Young-A;Sohn, Sung-Ok;Ji, Byung-Chul
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권6호
    • /
    • pp.763-768
    • /
    • 2006
  • The two-for-one(TFO) twister is precision machinery that twists fibers rapidly under constant tension. Since the quality of the twisted yarn is directly deteriorated by faults of the twister, such as the distortion of the spinning axis, bearing abrasion, and tension irregularity, it is important to detect faults of the TFO twister at an early stage. In this research, a new algorithm is proposed to detect faults of the TFO twister and their causes, by measuring the vibrations of the TFO twister and obtaining frequency components with a FFT algorithm. The TFO twister with faults showed increased vibrations and each fault generated vibrations at different frequencies. By analyzing changes of characteristics of vibrations, we can determine faulty twisters. The proposed fault detection algorithm can be implemented cheaply with a signal processor chip. It can be used to find when to repair a faulty TFO twister without much loss of yam on-line.

Highly Sensitive Biological Analysis Using Optical Microfluidic Sensor

  • Lee, Sang-Yeop;Chen, Ling-Xin;Choo, Jae-Bum;Lee, Eun-Kyu;Lee, Sang-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.130-142
    • /
    • 2006
  • Lab-on-a-chip technology is attracting great interest because the miniaturization of reaction systems offers practical advantages over classical bench-top chemical systems. Rapid mixing of the fluids flowing through a microchannel is very important for various applications of microfluidic systems. In addition, highly sensitive on-chip detection techniques are essential for the in situ monitoring of chemical reactions because the detection volume in a channel is extremely small. Recently, a confocal surface enhanced Raman spectroscopic (SERS) technique, for the highly sensitive biological analysis in a microfluidic sensor, has been developed in our research group. Here, a highly precise quantitative measurement can be obtained if continuous flow and homogeneous mixing condition between analytes and silver nano-colloids are maintained. Recently, we also reported a new analytical method of DNA hybridization involving a PDMS microfluidic sensor using fluorescence energy transfer (FRET). This method overcomes many of the drawbacks of microarray chips, such as long hybridization times and inconvenient immobilization procedures. In this paper, our recent applications of the confocal Raman/fluorescence microscopic technology to a highly sensitive lab-on-a-chip detection will be reviewed.