• 제목/요약/키워드: Check valve

검색결과 211건 처리시간 0.028초

AE 센서를 이용한 Check Valve 상태감시 시스템 구현 (Realization of Check Valve Condition Monitoring system using AE sensor)

  • 전정섭;이승연;백승문;유준;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.49-51
    • /
    • 2004
  • This paper presents a realization of fault detection algorithm and Fieldbus based communication for condition monitoring of check valve. We first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, extract fault features through the learned Neural network, and send the processed data to a remote site. The overall system has been implemented and experimental results are given to show its effectiveness.

  • PDF

An Experimental Study of the Swing Check Valve Disc Stability

  • Kim, Yang-Seok;Song, Seok-Yoon;Kim, Dae-Woong;Park, Sung-Keun;Hong, Sung-Yull
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.157-158
    • /
    • 2004
  • To investigate the effects of the upstream flow conditions on the opening performance of the swing check valve, the tests were performed at various conditions of the disturbance type and distance from the tested check valves. The results show that the upstream flow disturbances due to elbow and globe valve at $2{\sim}10$ diameters upstream of the check valve produced minor effects on the check valve performance compared to the uniform flow condition. However, more detail analysis and additional testing with the other disturbance source, such as orifice with a large number of holes, are needed to refine and confirm the present results.

  • PDF

Check Valve 상태감시를 위한 통신 및 센서신호처리 기능 구현 (Realization of Communication and Sensor Signal Processing Technique for Condition Monitoring of Check Valve)

  • 전정섭;조재근;김정수;유준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a realization of sensor signal processing(noise filtering) and Fieldbus based communication for condition monitoring of check valve. we first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, and their frequencies were analyzed to find the informative band. To reject background noises, bandpass filters have been designed. Also, to send the processed data to a remote site, wired communication facility has been realized via DeviceNet.

  • PDF

발전소 6 인치 역지밸브 손상 원인 분석 (Investigation on the Degradation Mechanism of 6" Swing Check Valve for Nuclear Power Plant)

  • 이선기;이준신;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.138-144
    • /
    • 2000
  • 원자력발전소 분기관에 설치되어 있는 6" swing check valve 중 일부에서 seat 면이 다소 손상되어 O/H 기간중에 시트면 연마정비 또는 밸브 교체정비를 수행하였다. 본 논문에서는 실험적 및 이론적 연구를 통하여 밸브 시트면 손상 원인을 분석하였으며, 분석 결과 구조공진 및 음향공진의 복합적인 작용에 의한 밸브 chattering이 손상 원인임을 규명하였다.

  • PDF

발전소 주급수 계통 감발 과정에서의 스윙체크밸브 닫힘 시점의 실험적 결정 (An Experimental Determination of a Swing Check Valve Closure Time in the Main Feed Water System of a Power Plant during Shut-down Process)

  • 서진성;김원민
    • 한국소음진동공학회논문집
    • /
    • 제19권8호
    • /
    • pp.843-849
    • /
    • 2009
  • The reliable operation of a swing check valve in the main feed water system of a power plant is most essential for successful shout-down process. A failure to close the valve at proper time often leads to the instability of the main feed water system, or even to an emergency stop of the power plant. In reality it is a very difficult task to monitor the behavior of a swing check valve. Furthermore it is impossible to see the motion of the valve. In this work two measurements were carried out simultaneously to determine the precise valve closure time. The dynamic pressure measurements were made at the inlet and outlet regions of the swing check valve. The transient vibration of the valve housing in the direction of water flow was also measured, which enabled the measurement of the transient vibration of the valve housing near valve closure. By comparing the results produced from these measurements the precise valve closure time could be determined. By carrying out order tracking technique using the dynamic pressure signals and pump rpm signal, the complicated dynamic problems inside the main feed water system can be more easily dealt with. This measurement scheme might be implemented in a power plant on a real-time basis without much difficulty. If this could be implemented, valuable information essential for shut-down operations can readily be passed on to the main control room. The feasibility of this implementation was demonstrated by this experimental work.

주택용 가스배관 체크앵글 안전밸브 개발 연구 (Development of Check Angle Safety Valve for Residential Gas Piping)

  • 임상호
    • 산업진흥연구
    • /
    • 제2권1호
    • /
    • pp.9-13
    • /
    • 2017
  • 본 연구는 주택용 가스배관 체크앵글 안전밸브에 관한 것으로 긴급 발생시 1초 이내에 수동으로 차단이 가능하고, 또 손의 힘으로 가압 3kg에 터치가 가능 하도록 하고, 또 긴급시 차단 작동 후 차단 볼 지름이 7mm로 번복 사용이 가능하도록 기술 개발 하였다. 연구결과 첫째 밸브 작동 후. 평균 0.61 초로 나타났다. 따라서 안전밸브로서 사용하여도 작동에는 문제가 없는 것으로 나타났다. 둘째, 손의 힘으로 가압 3kg이내 터치에 모두 작동 되었다. 셋째, 차단 볼 지름이 7mm로 번복 사용한 결과 모두 이상 없는 것으로 나타났다. 본 연구에서 가스배관 체크앵글 안전밸브를 개발하고 기존 밸브와의 시험을 통하여 성능을 검증한 것에 의미가 있다.

스윙형 역지밸브 성능 평가 방법 (Performance Evaluation Method of a Swing Check Valve)

  • 김양석;이도환;김대웅;박성근;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF