• Title/Summary/Keyword: Check valve

Search Result 211, Processing Time 0.035 seconds

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.

Customized unsteady analysis and minimization of damage due to unsteady flow in water distribution system (상수관망의 맞춤형 부정류해석 및 부정류피해 최소화 방안)

  • Kwon, Hyuk Jae;Yoo, Min Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.287-291
    • /
    • 2015
  • 본 연구에서는 두 지역의 실제 상수관망에 대해서 부정류해석을 수행하였고 각각의 상수관망에 필요한 부정류피해 최소화방안을 제시하였다. 첫 번째 대상지역은 베트남 호치민으로 148개 절점과 162개의 파이프로 이루어진 소블럭 상수관망이며 두 번째 대상지역은 파주시 광탄면으로 512개 절점과 527개의 파이프로 이루어진 세 개의 소블럭 상수관망이다. 두지역의 상수관망은 지형적면이나 규모면에서 다른 모습을 하고 있기 때문에 부정류해석 시 발생가능한 피해유형이 틀린 것으로 나타났다. 호치민의 경우 배수지의 높이가 낮고 도시 내 표고차가 없어서 관망 내 평균수압이 $1kg/cm^2$을 약간 상회하는 수준으로 수압이 낮고 수압차 역시 작다. 따라서 상수관망에서 일어날 수 있는 소요수량의 변화나 소화전 사용과 같은 작은 변화에도 역류발생이 빈번히 일어나는 것으로 나타났으며 역류발생이 잦은 파이프를 선정할 수 있었다. 상당히 많은 파이프에서 단기간 역류가 발생하는 것을 확인할 수 있었다. 짧은 기간에 발생하는 변화에 대한 단기간 역류는 교차연결(Cross-Connection)의 문제를 야기할 수 있다. 따라서 역류발생이 빈번히 일어나는 파이프 주위에 check valve나 역지밸브등의 설치를 통해 역류로 인한 피해를 최소화할 수 있다. 파주시 광탄면 지역의 소블럭 집합으로써 고저차가 많은 지역이다. 배수지 밸브개폐 시 발생 가능한 수충격에 대한 시뮬레이션과 펌프장정지로 인해 발생할 수 있는 수충격에 발생 시뮬레이션을 수행하였고 관망내에서 자주 발생하는 밸브개폐로 인한 시뮬레이션을 수행하였다. 그 결과 광탄의 경우 수충격 발생위험 지점은 배수지 근처로 나타났고 수격압이 최대 $2.5kg/cm^2$에서 $3.0kg/cm^2$까지 발생 가능한 것으로 나타났고 밸브개폐시간이 1-2초 지연되어도 상당히 큰 수격압을 줄일 수 있는 것으로 나타났다. 수충격압이 크게 발생할 수 있는 지역에 수충격피해 최소화를 위해 surge tank와 같은 장치를 설치해야 한다. 또한 발생가능한 수격압의 크기를 통계적기법을 통해 확률밀도함수로 나타낼 수 있었다. 이 결과는 앞으로 상수관망의 설계나 운영에서 수충격피해 방지 장치 및 설비를 시공할 때 장치의 규모나 용량을 결정할 때 유용한 정보가 될 것으로 판단된다.

  • PDF

Estimating Gastrointestinal Transition Location Using CNN-based Gastrointestinal Landmark Classifier (CNN 기반 위장관 랜드마크 분류기를 이용한 위장관 교차점 추정)

  • Jang, Hyeon Woong;Lim, Chang Nam;Park, Ye-Suel;Lee, Gwang Jae;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.3
    • /
    • pp.101-108
    • /
    • 2020
  • Since the performance of deep learning techniques has recently been proven in the field of image processing, there are many attempts to perform classification, analysis, and detection of images using such techniques in various fields. Among them, the expectation of medical image analysis software, which can serve as a medical diagnostic assistant, is increasing. In this study, we are attention to the capsule endoscope image, which has a large data set and takes a long time to judge. The purpose of this paper is to distinguish the gastrointestinal landmarks and to estimate the gastrointestinal transition location that are common to all patients in the judging of capsule endoscopy and take a lot of time. To do this, we designed CNN-based Classifier that can identify gastrointestinal landmarks, and used it to estimate the gastrointestinal transition location by filtering the results. Then, we estimate gastrointestinal transition location about seven of eight patients entered the suspected gastrointestinal transition area. In the case of change from the stomach to the small intestine(pylorus), and change from the small intestine to the large intestine(ileocecal valve), we can check all eight patients were found to be in the suspected gastrointestinal transition area. we can found suspected gastrointestinal transition area in the range of 100 frames, and if the reader plays images at 10 frames per second, the gastrointestinal transition could be found in 10 seconds.

Arthroscopic Direct Removal of Popliteal Cyst by Posteromedial Portal (관절경하 후내측 도달법을 이용한 슬와 낭종의 직접적 제거술)

  • Cho, Jin-Ho;Kim, Yong-Hoon;Kim, Dong-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.232-237
    • /
    • 2005
  • Purpose: To evaluate the effectiveness of arthroscopic direct cystic removal of popliteal cyst using 70 degree arthroscopy and posteromedial portal. Materials and Methods: From January 2003 to January 2004, 21 patients(23 cases) with popliteal cyst have been treated by direct cystic decompression with arthroscopy. The average age of the 21 patients was 54 years(range 35 to 78 years). There were 5 males and 16 females. Of the 23 cases,8 cases were occured in right side and 11 cases were occured in left side. 4 cases were both sides. In all cases, preoperative MRI were performed to detect combined intraarticular pathology. At 6 months and 1 year postoperatively, follow-up ultrasonography were performed to detect recurrence of cyst. We used Rauschning and Lindgren criteria for clinical evaluation. Results: All cases had no recurrence and no complaints of pain, swelling, or functional impairment at 1 year after surgery. At ultrasonography, no recurrence were founded. One complication was occurred. Postoperatively, Rauschning and Lindgren criteria were more than grade 1. Conclusion: Arthroscopic direct cystic removal using arthroscopy and posteromedial portal is an effective method in popliteal cyst surgery.

  • PDF

The Follow Up Results of Residual Spinoglenoid Ganglion Cyst after Arthroscopic Decompression and Superior Labral Repair - Cases Report - (극관절와 결절성 낭포의 관절경적 감압술 및 상부관절와순 봉합술 후 잔존 낭포의 경과 - 증례 보고 -)

  • Sung, Chang-Meen;Lee, Sang-Hyuk;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.111-116
    • /
    • 2010
  • Purpose: There are many known treatment modalities for spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy. However, to the author's knowledge, there is no report on the follow-up outcomes focused on remnant cysts. Materials and Methods: Six (n=6) patients with spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy, with a mean follow-up of 15 months (12-23months) following arthroscopic cyst decompression and superior labral repair, were enrolled. Residual cyst was investigated by ultrasonography and MRI. Results: Immediate postoperative ultrasonography revealed complete remission of ganglion cyst in one patient and reduced ganglion cyst size in five patients. Three-month follow-up ultrasonography showed spontaneous complete remission of the residual cysts in all patients. No recurrence on MRI was seen at one-year follow-up. Conclusion: Residual spinoglenoid ganglion cyst remaining after arthroscopic decompression and superior labral repair tends to resolve spontaneously within 3 months of surgery.

Performance Analysis and Test of the Small Piezoelectric-Hydraulic Pump Brake System (소형 압전유압펌프 브레이크 시스템의 성능해석 및 실험)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Nguyen, Anh Phuc;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.49-56
    • /
    • 2018
  • In this paper, the performance analysis and the experiment of the brake system using the small piezoelectric-hydraulic pump were performed. Initially, the 3-D modeling of the brake load components was performed for the construction of the brake system. Subsequently, modeling using the commercial program AMESim was performed. A floating caliper model was used as a load for modeling the brake system. Through the AMESim simulation, load pressure, check valve displacement and flow rate under no load state were calculated, and performance analysis and changes in dynamic characteristics were confirmed by adding brake load. A jig for use in fixing the brake load during performance test was manufactured. The flow rate was assessed under no load condition and load pressure formation experiments were performed and compared with simulation results. Experimental results revealed the maximum load pressure as about 73bar at 130Hz and the maximum flow rate as about 203cc/min at 145Hz, which satisfied the requirement of small- and medium-sized UAV braking system. In addition, simulation results revealed that the load pressure and discharge flow rate were within 6% and 5%, respectively. Apparently, the modeling is expected to be effective for brake performance analysis.

Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline (국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

Implementation of a Mixing-Ratio Control System for Two-Component Liquid Silicone Mixture (이액형 액상실리콘 재료의 혼합비율 제어 시스템 개발)

  • Choo, Seong-Min;Kim, Young-Min;Lee, Keum-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.688-694
    • /
    • 2018
  • The mixture ratio of two-component liquid silicone is important for the inherent physical characteristics of the finished product. Therefore, it is necessary to uniformly control the ratio of the main material and the sub-material. In this paper, a mixing-ratio control system was designed, which consists of a digital flow meter and a flow control system to measure the flow rate of the raw materials and a pumping system to maintain constant pressure and transfer of the raw materials. In addition, a program was developed to control the organic interlocking and mixing ratio. For the verification of the developed system, we compared the actual weight of raw material with the value measured by the flow meter during pumping, and we measured the physical properties of the mixed material by making test samples with and without the application of the mixing-ratio improvement algorithm. The measured value was close to the reference value with a hardness range of 46-47 and tensile strength of 9.3-9.5 MPa. These results show that the mixing ratio of the liquid silicone is controlled within an error range of ${\pm}0.5%$.

Estimation of Groundwater Table using Ground Penetration Radar (GPR) in a Sand Tank Model and at an Alluvial Field Site (실내 모형과 현장 충적층에서 지하투과레이더를 이용한 지하수면 추정)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Choi, Doo-Houng;Koh, Yong-Kwon
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.201-216
    • /
    • 2013
  • Ground penetrating radar (GPR) surveys were conducted in a sand tank model in a laboratory and at an alluvial field site to detect the groundwater table and to investigate the influence of saturation on GPR response in the unsaturated zone. In the sand tank model, the groundwater table and saturation in the sand layer were altered by injecting water, which was then drained by a valve inserted into the bottom of the tank. GPR vertical reflection profile (VRP) data were obtained in the sand tank model for rising and lowering of the groundwater table to estimate the groundwater table and saturation. Results of the lab-scale model provide information on the sensitivity of GPR signals to changes in the water content and in the groundwater table. GPR wave velocities in the vadose zone are controlled mainly by variations in water content (increased travel time is interpreted as an increase in saturation). At the field site, VRP data were collected to a depth of 220 m to estimate the groundwater table at an alluvial site near the Nakdong river at Iryong-ri, Haman-gun, South Korea. Results of the field survey indicate that under saturated conditions, the first reflector of the GPR is indicative of the capillary fringe and not the actual groundwater table. To measure the groundwater table more accurately, we performed a GPR survey using the common mid-point (CMP) method in the vicinity of well-3, and sunk a well to check the groundwater table. The resultant CMP data revealed reflective events from the capillary fringe and groundwater table showing hyperbolic patterns. The normal moveout correction was applied to evaluate the velocity of the GPR, which improved the accuracy of saturation and groundwater table information at depth. The GPR results show that the saturation information, including the groundwater table, is useful in assessing the hydrogeologic properties of the vadose zone in the field.