• Title/Summary/Keyword: Charging and discharging time

Search Result 125, Processing Time 0.028 seconds

Characteristics of Trap in the Thin Silicon Oxides with Nano Structure

  • Kang, C.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.6
    • /
    • pp.32-37
    • /
    • 2003
  • In this paper, the trap characteristics of thin silicon oxides is investigated in the ULSI implementation with nano structure transistors. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The transient current was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The stress induced leakage current will affect data retention in electrically erasable programmable read only memories. The oxide current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 113.4nm and 814nm, which have the gate area 10$\^$-3/ $\textrm{cm}^2$. The stress induced leakage currents will affect data retention, and the stress current and transient current is used to estimate to fundamental limitations on oxide thicknesses.

SILC of Silicon Oxides

  • Kang, C.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.428-431
    • /
    • 2003
  • In this paper, the stress induced leakage currents of thin silicon oxides is investigated in the ULSI implementation with nano structure transistors. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The transient current was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The stress induced leakage current will affect data retention in electrically erasable programmable read only memories. The oxide current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between $113.4{\AA}$ and $814{\AA}$, which have the gate area 10-3cm2. The stress induced leakage currents will affect data retention and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses.

  • PDF

Stochastic Real-time Demand Prediction for Building and Charging and Discharging Technique of ESS Based on Machine-Learning (머신러닝기반 확률론적 실시간 건물에너지 수요예측 및 BESS충방전 기법)

  • Yang, Seung Kwon;Song, Taek Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.157-163
    • /
    • 2019
  • K-BEMS System was introduced to reduce peak load and to save total energy of the 120 buildings that KEPCO headquarter and branch offices use. K-BEMS system is composed of PV, battery, and hybrid PCS. In this system, ESS, PV, lighting is used to save building energy based on demand prediction. Currently, neural network technique for short past data is applied to demand prediction, and fixed scheduling method by operator for ESS charging/discharging is used. To enhance this system, KEPCO research institute has carried out this K-BEMS research project for 3 years since January 2016. As the result of this project, we developed new real-time highly reliable building demand prediction technique with error free and optimized automatic ESS charging/discharging technique. Through several field test, we can certify the developed algorithm performance successfully. So we will describe the details in this paper.

Rapid Charger for 48V Lead-acid Battery (48V용 납축전지 급속 충전기)

  • Ahn, S.H.;Jang, S.R.;Ryoo, H.J.;Mo, S.C.;Oh, S.W.;Park, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.945_946
    • /
    • 2009
  • This paper describes the development of the rapid battery charger for lead-acid battery. Due to heat which is caused by increased internal resistance during charging, it is difficult to increase charging current for the lead-acid battery. In this paper, the rapid charging algorithm which apply short discharging pulse current during charging procedure is developed and it makes the ion layer, which is generated during charging time, disappeared into electrolyte. The prototype battery charger based on resonant converter is developed for 48V battery charger and test procedure is introduced.

  • PDF

A Capacitor Charging Power Supply(CCPS) using Dead Time Control Circuit for Stable High Repetition (안정적 고반복을 위한 지연시간 제어회로가 적용된 커패시터 충전용 전원장치)

  • Lim, Tae Hyun;Hwang, Sun Mook;Kook, Jeong Hyeon;Yim, Dong Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.55-60
    • /
    • 2017
  • Capacitor Charging Power Supply(CCPS) is one of the most important components of a pulsed power system. The CCPS is widely used in source of lasers, accelerators and plasma generators. This paper presents design of a dead time control circuit and operation characteristics for stable high repetition rate of high voltage CCPS. The CCPS consists of battery, high voltage transformer and controller with a dead time control circuit. A dead time control circuit was simulated by PSpice. The performance test of the CCPS was carried out with a 7[nF] load capacitor at output voltage of 50[kV] and a pulse repetition frequency of 100[Hz]. As a result, we can verify that charging and discharging waveform is stable at 100[Hz]. The experiment results indicate that 3[ms] dead time made it possible for stable high repetition rate of 100[Hz]. This paper paves the way for designing an advanced CCPS which is more applicable outside experiments.

A Study on the Electrical Properties of Ethylene Propylene Rubber by Thermal Treatment and Irradiation (방사선 및 열처리에 의한 에틸렌프로필렌 고무의 전기적 특성에 관한 연구)

  • 이성일
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.4
    • /
    • pp.137-146
    • /
    • 2002
  • In order to investigate the effect of irradiation by $^{60}Co-\gamma$rays as well as the e thermal treatment on the dielectric deterioration in ethylene propylene rubber, insulating material for electric cables used in atomic power plants, charging discharging current, residual built- up voltage and dielectric properties are measu discussed in this study. Variance in the characteristic of relative dielectric constant as a function of tem was observed in relatively high dose of irradiation. Since glass transition tem appeared at tens of degree Celsius below zero, the characteristic is attributed orientation polarization. Dielectric loss is generally increased, with increasing d irradiation in the characteristic of dielectric loss as a function of temperature, No d loss by thermal treatment was observed. Dielectric resistance decreases with increa of irradiation in the characteristic of charging current as a function of temperature be considered that dielectric resistance seems to be recovered by thermal treatm characteristic of discharging current as a function of time in the specimen less ir become similar to that of the unirradiated, when thermal treated. A peak is shown residual built- up voltage as a function of time, and the corresponding time of the shorten as increasing dose of irradiation. It is also observed that the corresponding the peak is lengthened by thermal treatment.

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

Performance Simulation and Analysis of the Solar Thermal Storage System Using Heat Pipe (히트파이프를 사용한 태양열 축열시스템의 성능모사 및 해석)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kim, Jong-Kyu;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.80-85
    • /
    • 2009
  • Mathematical modeling and performance simulation results were shown for the solar thermal storage system which used heat pipe. The thermal storage system was composed of thermal storage tank and charging/discharging heat exchanger with one by the heat pipes. Heat pipe heat exchanger was attached to system, and could carry out charging and discharging to thermal storage tank at the same time. Height of the thermal storage tank was 600 mm, and that of the charging/discharging heat exchanger was 400 mm. Length of the heat pipe was the same as the total height of thermal storage system, and outer and inner diameter were 25.4 mm(O.D.) and 21.4 mm(I.D.) respectively. Diameter of the circular was 43 mm(O.D.), and fin geometries were considered as the design parameters. High temperature phase change material(PCM), $KNO_3$ and low temperature PCM, $LINO_3$ were charged to storage tank to adjust working temperature. Total size of thermal storage system able to get heat capacity more than 500 kW was calculated and the results were shown in this study. Number of heat pipe was required more than maximum 500, and total length of thermal storage system was calculated to the more than maximum 3 m at various condition.

  • PDF

Characteristics Analysis of Capacitor Discharge Impulse Magnetizing Circuit using SPICE (SPICE를 이용한 커패시터 방전 임펄스 착자 회로의 특성 해석)

  • 백수현;김필수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.206-215
    • /
    • 1994
  • A method for simulating general characteristics and temperature characteristics of discharging SCR of the capacitor discharge impulse magnetizer-magnetizing fixture system using SPICE is presented. This method has been developed which can aid the design, understanding and inexpensive, time-saving of magnetizing circuit. As the detailed characteristic of magnetizing circuit can be obtained, the efficient design of the magntizing circuit which produce desired magnet will be possible using our SPICE modeling. Especially, computation of the temperature rise of discharging SCR is very important since it gives some indication of thermal characteristic of discharging circuit. It is implemented on a 486 personal computer, and the modeling results are checked against experimental measures. The experimental results have been achived using 305[V] and 607[V] charging voltage, low-energy capacitor discharge impulse magnetizer-magnetizing fixture of air cleaner DC motor.

  • PDF

단결정 태양전지의 시정수

  • Jeong, Yu-Ra;Choe, Yong-Seong;Lee, Gyeong-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.11-11
    • /
    • 2010
  • Recently, annual usage of energy is dramatically increasing by industrialization is going faster and more electricity is needed due to various electronic devices. This paper present relationships between the Vmax, $V_T$, load and time constant of solar cell charge and discharge curve. Charging and discharging recording where the external resistance will become larger Vmax, $V_T$ is decrease and the time increases and decreases there is a possibility of knowing.