• 제목/요약/키워드: Charged particles

Search Result 341, Processing Time 0.023 seconds

A Theoretical Study on the Initial Collection Efficiency of Submicron Particles by a Unipolar Charged Fiber (단일 전하로 하전된 단일 섬유에서의 미세입자의 초기 집진효율에 관한 이론적 연구)

  • 오용학;전기준;정용원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.3
    • /
    • pp.259-268
    • /
    • 2001
  • In this study, we have developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber in the electret filters. The particle sizes considered were in the submicron range and thus Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigators experimental data on single fiber efficiency as well as with the calculated results using the existing correlations on single fiber efficiency. It has been shown that simulation results are in good agreement both with the experimental data with those predicted by the correlations.

  • PDF

Penetration Efficiency of Charged Particles in a Cylindrical Tube Connection with Electrical Voltage Difference

  • Song, Dong-Keun;Kim, Tae-Oh
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E1
    • /
    • pp.29-38
    • /
    • 2007
  • A cylindrical tube connection that has a voltage difference and is separated electrically by an insulator was modelled. The penetration efficiencies of charged particles passing through the connector tube were investigated. Typically, as the particle size decreases and the applied voltage difference increases, the penetration efficiency decreases. To assess the effect of the electrode geometry, various lengths of electric insulator and aerosol flow rate with a fixed tube length and tube diameter were used when calculating penetration efficiencies. The comparison of penetration efficiencies for various electrode geometry setups suggests that the penetration efficiency can be described as a function of the product of applied voltage and electrical mobility of charged particles. The diffusion loss from this and previous studies are compared. Further, an explicit form for penetration efficiency is provided as a function of a new non-dimensional parameter, $Es(=Z_pV/U_{avg}W);\;P_{es}=0.2{\cdot}{\exp}(-Es/0.6342)+0.8{\cdot}{\exp}(-Es/4.7914)$.

Transports of Ferrihydrite Colloids in Packed Quartz Sand Media (석영모래 속에서의 Ferrihydrite 콜로이드 이동)

  • Kim, Seok-Hwi;Gu, Baohua;Lee, Jae-Hoon;Wang, Wei;Park, Ki-Hoon;Kim, Kang-Joo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.4 s.50
    • /
    • pp.231-238
    • /
    • 2006
  • Transports of heterogeneously charged particles were investigated based on column experiments. Synthesized mono-dispersed ferrihydrite (${\sim}100nm$) and amorphous $SiO_2\;({\sim}40nm\;and\;{\sim}80nm)$ particles, of which surfaces are oppositely charged under pH < 9.0 (ferrihydrite, positive; amorphous silica, negative), were used. $177{\sim}250{\mu}m$ quartz sand was used as a stationary matrix. The results show that even favorable particles (i.e., ferrihydrite) can show a conservative transport through the oppositely charged media (i.e., quartz) when they coexist with humic acid or with much greater number of oppositely charged particles. These results imply that transports of both negatively and positively charged contaminants may be possible at the same time under a condition of heterogeneous colloidal system.

Motion of Charged Micro-particle Immersed in Liquid Crystal Controlled by In-plane Field for Electro Paper Display

  • Baik, In-Su;Choi, Ju-Hwan;Jung, Byoung-Sun;Jeon, Sang-Youn;Song, Eun-Kyoung;Lee, Seung-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.30-35
    • /
    • 2006
  • We have studied the motion of charged micro-particles that are immersed in a nematic liquid crystal (LC) and controlled by in-plane field. The LC is an anisotropic liquid such that the viscosity of the LC depends on flow direction, phase of the LC, and temperature, which affects the motion of the charged particles under the influence of electric field. This study shows that the motion of charged particles mainly depends on the applied voltage and the LC phase, but does not show any significant influence from the initial alignment of LC, although one may expect directional difference in drag force due to interaction between LC and particle. The viscosity changes due to temperature variations in nematic phase also show no signification influence on particle velocity when compared to the effect from varying in-plane field strength.

An Experimental Study on the Characteristics of Direct Photoelectric Charging (직접 광대전의 대전특성에 관한 실험적 연구)

  • Lee, Chang-Sun;Kim, Yong-Jin;Kim, Sang-Sao
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.753-759
    • /
    • 2000
  • Photoelectric charging is a very efficient way of charging small particles. This method can be applied to combustion measurement, electrostatic precipitator, metal separation and control of micro-contamination. To understand the photoelectric charging mechanism, particle charging of silver by exposure to ultraviolet is investigated in this study. Average charges and charge distributions are measured at various conditions, using two differential mobility analyzers, a condensation nucleus counter, and an aerosol electrometer. The silver particles are generated in a spark discharge aerosol generator. After that process, the generated particles are charged in the photoelectric charger using low-pressure mercury lamp that emits ultraviolet having wavelength 253.7 nm. The results show that ultra-fine particles are highly charged by the photoelectric charging. The average charges linearly increase with increasing particle size and the charge distribution change with particle size. These results are discussed by comparison with previous experiments and proposed equations. It is assumed that the coefficient of electron emission probability is affected by initial charge. The results also show that the charge distribution of a particle is dependent on initial charge. Single changed particle, uncharged particle and neutralized particle are compared. The differences of charge distribution in each case increase with increasing particle size.

Development and Performance Evaluation of Positively Charged Porous Filter media for Water Purification System (정수 설비를 위한 양전하가 부가된 다공성 수처리 필터 개발과 성능평가)

  • Lee, Chang-Gun;Joo, Ho-Young;Lee, Jae-Keun;Ahn, Young-Chull;Park, Seong-En
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.95-98
    • /
    • 2006
  • Filtration by fibrous filter is one of the Principle methods used for removing pollutant particles in the liquid. Because of the increasing need to protect both human health and valuable devices from exposure to fine particles, filtration has become more important. Filters have been developed with modified surface charge characteristics to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in water. The main purposes of this study are to develop and evaluate the performance evaluation of the apparatus for making a positively charged porous filter media and to analyze the surface characteristics of the filter media for capturing negavitely charged contaminants mainly bacteria and virus from water. The experimental apparatus consists of a mixing tank, a vacuum pumping system, a injection nozzle, a roller press and a controller. The filter media is composed of glass fiber(50-750 nm), cellulose($10-20{\mu}m$) and colloidal charge modifier. The characteristics of filter media is analyzed by SEM(Scanning Electron Microscopy), AFM(Atomic Force Microscopy) and quantified by measuring the zeta potential values.

  • PDF

Determination of Charged Particles and their Polarity by Temperature Gradient Thermally Stimulated Measurement (온도구배 열자격 측정에 의한 하전입자의 구별 및 극성 판정)

  • 권영수;강도열;국상훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.600-609
    • /
    • 1989
  • A thermally stimulated measurement using a temperature gradient has been applied to the study of charged particles and their polarity n polymers. From the experimental results on a cross-linked polyethylene (XLPE) film is found that the TSC peaks of the trapped carriers in C peak are due to the negative polarity which is electron and the ionic carriers having negative polarity show D peak.

  • PDF

Numerical Simulation for the Aggregation of Charged Particles (하전입자의 응집성장에 대한 수치적 연구)

  • Park, Hyung-Ho;Kim, Sang-Soo;Chang, Hyuk-Sang
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.605-611
    • /
    • 2001
  • A numerical technique for simulating the aggregation of charged particles was presented with a Brownian dynamic simulation in the free molecular regime. The Langevin equation was used for tracking each particle making up an aggregate. A periodic boundary condition was used for calculation of the aggregation process in each cell with 500 primary particles of 16 nm in diameter. We considered the thermal force and the electrostatic force for the calculation of the particle motion. The morphological shape of aggregates was described in terms of the fractal dimension. The fractal dimension for the uncharged aggregate was $D_{f}=1.761$. The fractal dimension changed slightly for the various amounts of bipolar charge. However, in case of unipolar charge, the fractal dimension decreased from 1.641 to 1.537 with the increase of the average number of charges on the particles from 0.2 to 0.3 in initial states.

  • PDF

Doping Effects and Semiconductor Behaviors of the Dispersed p- and n- type Semiconductor Particles (분산된 p형 및 n형 반도체 입자의 도핑 효과와 반도체 동작)

  • 천장호;손광철;라극환;조은철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.126-133
    • /
    • 1994
  • Doping effects and semiconductor behaviors of the dispersed p- and n-Si, p- and n- GaAs particles in the aqueous electrolyte have been studied using microelectrophoretic, voltammetric and chronoamperometric techniques. The cations (K$^{+}$) are adsorbed on both the p- and n- Si particle surfaces regardless of the sign of space charges in the depletion layers, i.e. doping profiles. The surface states are negatively charged acceptor states. On the other hand, the anions (CI$^{-}$) are adsorbed on both the p- and n- GaAs particle surfaces regardless of the sign of space charges in the depletion layers, i.e. doping profiles. The surface states are positively charged donor states. Under the same conditions, electrophoretic mobilities, electrochemical processes, doping effects and related semiconductor behaviors of the Si and the GaAs particles are similar regardless of the doping profiles, i. e. dopants and doping concentrations. The doping effects and related semiconductor behaviors of the dispersed p- and n- type semiconductor particles are gradually lost with decreasing dimensions.

  • PDF

고진공에서 이온 카운터를 사용한 실시간 입자 모니터링 시스템의 개발

  • An Gang-Ho;Kim Yong-Min;Yun Jin-Uk;Gwon Yong-Taek
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.255-258
    • /
    • 2006
  • In this paper, the new method which is monitoring quantity of particles using by ion-counter has been developed. ISPM system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. Ion-counter applied positive voltage could detect only positive charged particles. Therefore charged particles to Boltzmann equilibrium distribution or to some identified charge distribution can be detected by ion-counter. Ion-counter could install on the exhaust line of process equipment since pressure loss is structurally low. ISPM system has been certified by comparison with the result of SMPS (Scanning Mobility Particle Sizer) system. The relation coefficiency is above 0.98 about $20{\sim}300nm$ particles with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF