• Title/Summary/Keyword: Charge.Discharge mode

Search Result 45, Processing Time 0.022 seconds

Effect of Relative Humidity, Disk Acceleration, and Rest Time on Tribocharge Build-up at a Slider-Disk Interface of HDD (HDD에서 상대습도, 디스크 가속도, 정지시간이 슬라이더-디스크 인터페이스의 마찰대전 발생에 미치는 영향)

  • Hwang J.;Lee D.Y.;Lee J.;Choa S.H.
    • Tribology and Lubricants
    • /
    • v.22 no.2
    • /
    • pp.59-65
    • /
    • 2006
  • In hard disk drives as the head to disk spacing continues to decrease to facilitate recording densities, slider disk interactions have become much more severe due to direct contact of head and disk surfaces in both start/stop and flying cases. The slider disk interaction in CSS (contact-start-stop) mode is an important source of particle generation and tribocharge build-up. The tribocharge build-up in the slider disk interface can cause ESD (electrostatic discharge) damage. In turn, ESD can cause severe melting damage to MR or GMR heads. The spindle speed of typical hard disk drives has increased in recent years from 5400 rpm to 15000 rpm and even higher speeds are anticipated in the near future. And the increasing disk velocity leads to increasing disk acceleration and this might affect the tribocharging phenomena of the slider/disk interface. We investigated the tribocurrent/voltage build-up generated in HDD, operating at increasing disk accelerations. In addition, we examined the effects with relative humidity conditions and rest time. We found that the tribocurrent/voltage was generated during pico-slider/disk interaction and its level was about $3\sim16pA$ and $0.1\sim0.3V$, respectively. Tribocurrent/voltage build-up was reduced with increasing disk acceleration. Higher humidity conditions $(75\sim80%)$ produced lower levels tribovoltage/current. Therefore, a higher tribocharge is expected at a lower disk acceleration and lower relative humidity condition. Rest time affected the charge build-up at the slider-disk interface. The degree of tribocharge build-up increased with increasing rest time.

An On-chip ESD Protection Method for Preventing Current Crowding on a Guard-ring Structure (가드링 구조에서 전류 과밀 현상 억제를 위한 온-칩 정전기 보호 방법)

  • Song, Jong-Kyu;Jang, Chang-Soo;Jung, Won-Young;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.105-112
    • /
    • 2009
  • In this paper, we investigated abnormal ESD failure on guard-rings in the smart power IC fabricated with $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology. Initially, ESD failure occurred below 200 V in the Machine Model (MM) test due to current crowding in the parasitic diode associated with the guard-rings which are generally adopted to prevent latch-up in high voltage devices. Optical Beam Induced Resistance Charge (OBIRCH) and Scanning Electronic Microscope (SEM) were used to find the failure spot and 3-D TCAD was used to verify cause of failure. According to the simulation results, excessive current flows at the comer of the guard-ring isolated by Local Oxidation of Silicon (LOCOS) in the ESD event. Eventually, the ESD failure occurs at that comer of the guard-ring. The modified comer design of the guard-ring is proposed to resolve such ESD failure. The test chips designed by the proposed modification passed MM test over 200 V. Analyzing the test chips statistically, ESD immunity was increased over 20 % in MM mode test. In order to avoid such ESD failure, the automatic method to check the weak point in the guard-ring is also proposed by modifying the Design Rule Check (DRC) used in BCD technology. This DRC was used to check other similar products and 24 errors were found. After correcting the errors, the measured ESD level fulfilled the general industry specification such as HBM 2000 V and MM 200V.

A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction (온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구)

  • Lee, Wongoo;KIM, Kang-Won;KIM, Balho H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • ESS(Energy Storage System) is an important source that keeps power supply stable and utilizes electricity efficiently. For example, ESS contributes to resolve power supply imbalance, stabilize new renewable energy output and regulate frequency. ESS is predicted to be expanded to 55.9GWh of installed capacity by 2023, which is 30 times more than that of 2014. To raise competitiveness of domestic ESS industry in this increasing world market, we have disseminated load-shift ESS for continuous power supply imbalance with FR ESS, and also necessity to secure domestic track record is required. However in case of FR ESS, utility of installing thermal power plant is generally generated within 5% range of rated capacity, so that scalability of domestic market is low without dramatic increase of thermal power plant. Necessity of load-shift ESS dissemination is also decreasing effected by surplus backup power securement policy, raising demand for new dissemination model. New dissemination model is promising for $CO_2$ reduction effect in spite of intermittent output. By stabilizing new renewable energy output in connection with new renewable energy, and regulating system input timing of new renewable energy generation rate, it is prospected model for 'post-2020' regime and energy industry. This research presents a policy alternatives of REC multiplier calculation method to induce investment after outlining PV-connected ESS charge/discharge mode to reduce GHG emission, This alternative is projected to utilize GHG emission reduction methodology for 'Post-2020' regime, big issue of new energy policy.

Frequency Dependency of Electrical Property Stabilization during Vulcanization of Modified NR/IR Blends (개질된 NR/IR 블랜드의 가황 반응에서 나타나는 전기적 특성 안정화의 주파수 의존성)

  • Ahn, Won-Sool
    • Elastomers and Composites
    • /
    • v.39 no.3
    • /
    • pp.179-185
    • /
    • 2004
  • Frequency dependency or electrical property stabilization during vulcanization of modified NR/IR composite materials was studied using in-situ electrical property measuring technique. Volume resistivity(p) before and after vulcanization reaction of the sample was measured as the function or frequency in the range or 1Hz to 10kHz at reaction temperatures of 130, 140, 150, and $160^{\circ}C$, respectively. A double stabilization mode of frequency dependency was observed, in which a slow stabilization process of p to a value of ca. $1.0{\times}10^7\;{\Omega}-cm$ occurred after a drastic initial decrease from ca. $9.0{\times}10^7\;{\Omega}-cm$. In addition, notable temperature dependencies of p values were also observed before and after vulcanization reaction, that is, p values at 130 and $140^{\circ}C$ after vulcanization were observed as about 1/3 of those values before vulcanization. All the observed facts were considered as the results from the interaction between the electrode and the bulk sample materials, i.e., electronic charge-discharge, and from the structure change of samples including CB rearrangement by the vulcanization.

The Study on Control Algorithm of Elevator EDLC Emergency Power Converter (승강기 EDLC 비상전원 전력변환장치 제어 알고리즘 연구)

  • Lee, Sang-min;Kim, IL-Song;Kim, Nam
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.6
    • /
    • pp.709-718
    • /
    • 2017
  • The installation of the elevator ARD(Automatic Rescue Device) system has been forced into law in these days in order to safely rescue passengers during power failure. The configuration of the ARD system consists of energy storage device, power converter and control systems. The EDLC(Electric Double Layer Capacitor) are used as energy storage device for rapid charge/discharge purposes. The power conditioning system (PCS) consists of bi-directional converter, 3-phase converter and control system. The dead-beat control system is adopted for most systems however it requires complex mathematical calculations, the high performance microprocessors are mandatory and thus it can be a cause of high manufacturing cost. In this paper the new control method for average current mode control is presented for simple structure. The control algorithm is applied to the single phase system and then expands to three phase system to meet the sysem requirements. The mathematical modeling using average modeling method is presented and analysed by PSIM computer simulation to verifie the validity of the proposed control methods.