• Title/Summary/Keyword: Charge.Discharge mode

Search Result 45, Processing Time 0.026 seconds

The Battery Management System for UPS Lead-Acid Battery (UPS용 납축전지를 위한 배터리관리시스템)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.127-133
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system control the currents and voltages of battery for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It proved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge (정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit (전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계)

  • Ko, Seok-Cheol;Lim, Sung-Hun;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF

Coordinated State-of-Charge Control Strategy for Microgrid during Islanded Operation

  • Kim, Jong-Yul;Jeon, Jin-Hong;Kim, Seul-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.824-833
    • /
    • 2012
  • In this paper, a coordinated state-of-charge (SOC) control strategy for the energy storage system (ESS) operating under microgrid islanded mode to stabilize the frequency and voltage was proposed. The proposed SOC control loop is made up of PI controller, which uses a SOC state of the energy storage system as an input and an auxiliary reference value of secondary control as an output. The SOC controller changes the auxiliary reference value of secondary control to charge or discharge the ESS. To verify the proposed control strategy, PSCAD/EMTDC simulation study was performed. The simulation results show that the SOC of the ESS can be regulated at the desired operating range without degrading the stabilizing control performance by proposed coordinated SOC control method.

Charge-Pump High Voltage Inverter for Plasma Backlight with Current Injection Method (CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압 Inverter)

  • Jang, Jun-Ho;Kang, Shin-Ho;Lee, Jun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.381-383
    • /
    • 2007
  • Charge-pump high voltage inverter for Plasma backlight with CIM(Current Injection Method) is proposed in this paper. Adoption of ERC is a new attempt in high voltage inverter so that it is not only energy recovery but also improvement of discharge stability and system unstability which is interrupted by noise. Using a charge-pump technique enables low voltage switches to be usable, the cost can be reduce. CIM is adopted to achieve high speed energy recovery in proposed circuit. Operations of the proposed circuit are analyzed for each mode. The proposed circuit is verified to be applicable on a 32 inch plasma backlight panel by experimental results.

  • PDF

CMI Tolerant Readout IC for Two-Electrode ECG Recording (공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로)

  • Sanggyun Kang;Kyeongsik Nam;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Charge-Pump High Voltage Inverter for Plasma Backlight using Current Injection Method (CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압Inverter)

  • Jang, Jun-Ho;Kang, Shin-Ho;Lee, Kyung-In;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.386-393
    • /
    • 2007
  • Charge-pump high voltage inverter for Plasma backlight using CIM(Current Injection Method) is proposed in this paper. Adoption of ERC(Energy Recovery Circuit) is a new attempt in high voltage inverter so that it is not only energy recovery but also improvement of discharge stability and system unstability which is interrupted by noise. Using a charge-pump technique enables low voltage switches to be usable, the cost can be reduced. CIM is adopted to achieve high speed energy recovery in proposed circuit. Operations of the proposed circuit are analyzed for each mode. The proposed circuit is verified to be applicable on a 32 inch plasma backlight panel by experimental results.

A High Efficiency Bidirectional Resonant Converter With Auxilary LC Circuit for V2G System (V2G 시스템을 위한 보조 LC 회로를 가진 고효율 양방향 공진형 컨버터)

  • Tranand, Duc-Hung;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.323-324
    • /
    • 2016
  • In this paper a high efficiency bidirectional resonant converterfor Vehicle-to-Grid applications (V2G) is proposed.The proposed converter has adopted an LC auxiliary circuit in the third winding of the transformer. With the proposed method full softswitching can be ensured in all switches over a wide range of loadsand the secondary ringing can be removed with no additional snubber or clamp circuitry.In addition, since the proposed resonant converter is able to operate at an almost constant resonant frequencyregardless of the load, CC/CV charge of the battery can be simply implemented with high efficiency. A 3.3 kW bidirectional converter for On-Board Charger of Electric Vehicle is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both charge and discharge mode. The maximum efficiency of the proposed system was 98.13 % at 2.3 kW during the constant voltage mode charge operation.

  • PDF

Modification of Polymer Surface by Corona Discharge and the Subsequent Graft Polymerization of Acrylamide (코로나 방전처리와 아크릴아미드 그라프트 중합에 의한 고분자 표면개질)

  • 김형우;김찬영;박병기
    • Textile Coloration and Finishing
    • /
    • v.5 no.1
    • /
    • pp.26-32
    • /
    • 1993
  • This study is concerned with the graft polymerization of acrylamide onto the surfaces of polyethylene and polyethylene terephthalate films treated with on corona discharge. In the case, peroxides formed by the corona discharge treatment are likely to be the species responsible for initiating the graft polymerization. This treatment produced a continuous charge in wettability and also amid group density on the polymer surface, as evidenced by water contact angle measurement, Fourier-transform infrared spectroscopy in the attenuated total reflectance mode, and electron spectroscopy for chemical analysis. Both of the merely corona-treated film and the subsequently grafted film are discussed as a function of time after treatment and water washings.

  • PDF

The Lithium Ion Battery Technology

  • Lee, Ki-Young
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.72-75
    • /
    • 2001
  • The performance of Li-ion system based on $LiCoO_2$ and Graphite is well optimized for the 3C applications. The charge-discharge mode, the manufacturing process, the cell performance and the thermal reactions affecting safety has been explained in the engineering point of view. The energy density of the current LIB system is in the range of 300~400 Wh/l. In order to achieve the energy density higher than 500 Wh/l, the active materials should be modified or changed. Adopting new high capacity anode materials would be effective to improve energy density.

  • PDF