• 제목/요약/키워드: Charge decay

검색결과 91건 처리시간 0.036초

New Calculation of Charge Generation Efficiency and Photocurrent in Organic Photoconducting Device

  • Lee, Choong-Kun;Oh, Jin-Woo;Choi, Chil-Sung;Lee, Nam-Soo;Kim, Nak-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.97-101
    • /
    • 2009
  • A new approach was applied to examine the charge generation and transport in organic photoconductive devices by Monte‐Carlo simulation utilizing multiple site interactions of carriers with all other charges within Coulomb radius. Stepwise generation frame was considered first by a charge separation process that was counted in two separate transactions, i.e., hopping against physical decay and dissociation against recombination. Thereafter, diffusion/ drifting process of free carriers was counted to follow. This method enables to examine readily the photocurrent generated alongside the charge generation efficiency. The field and temperature dependences of the efficiency and photocurrent were obtained comparable to Onsager’s and experimental data.

Influence of Endurance tests on Space Charge Distribution of 160kV HVDC XLPE Cable

  • Liu, Yun-Peng;Liu, He-Chen
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.302-309
    • /
    • 2017
  • The ageing of XLPE cable insulation will lead to the accelerating accumulation of space charge, which will greatly affect the safe operation of the HVDC cable. In order to investigate the influence of different ageing modes on the space charge distribution of the HVDC cable, thermal stressed, electrical stressed and electro-thermal stressed endurance tests were carried out on the XLPE peelings. The tested XLPE peelings were obtained from 160kV HVDC cable insulation. The endurance tests were carried at thermal stress of 363K, electrical stress of 20kV/mm DC and a combination of both. The Pulsed Electro-Acoustic (PEA) method was used to measure the space charge distribution of the samples. The influences of ageing on the trap energy distribution were analyzed based on the isothermal relaxation theory and the decay characteristics of the space charge. The results showed that thermal ageing would help to improve the crystalline morphologies of the XLPE at the early stage. The total amount of space charge decreased compared to the ones before thermal ageing. The long term of electrical stress would result in the cleavage of polymer molecule chains which would intensify the accumulation of space charge and increase the density and depth of electron traps. With a combination of electrical and thermal stress, the injection and migration of space charge were more significant. Besides, the depth and density of electron traps increased rapidly with the increase of endurance time.

E-빔 조사하에서 유리의 전하축퇴 특성 (Characteristics of Charge Accumulation in Glass Materials under E-Beam Irradiation)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.377-378
    • /
    • 2008
  • Space charge formation in various glass materials under electron beam irradiation was investigated. Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples. Furthermore, the dependence of the polarity of accumulated charges on the component of glass materials is discussed by using the models of energy bands.

  • PDF

자외선 조사된 Poly(ethylene terephthalate) 필름의 표면 열화 분석 (Analysis of the Surface Degradation in UV-irradiated Poly(ethylene terephthalate) films)

  • 임경범;이백수;황명환;김용운;임헌찬;최충석;남광우;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1457-1459
    • /
    • 2001
  • This paper deals with the change of surface Potential decay, surface resistivity, contact an91e and XPS of ultraviolet-treated PET films. From the experimental results on the surface Potential decay of UV degraded-samples, it was found that the accumulation of charge is decreased and the surface potential decay time is shortened. Also, from the result of XPS, it was found that the changes affected by the surface degradation of PET film were caused by the generation of carboxyl groups through the chain decomposition and recombination with oxygen molecules in the air.

  • PDF

리니어타잎 초전도 전원장치의 동작특성 (Operating characteristics of linear type magnetic flux pump)

  • 정윤도;배덕권;윤용수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.665-666
    • /
    • 2008
  • Inserted HTS (high temperature superconducting) coil is promisingly expected as a solution for achievement of higher fields such as GHz scale NMR magnet. However, HTS magnet causes persistent current decay in the persistent current mode and this decay should be compensated in order to keep stable magnetic field. As a solution for the decay in the HTS magnets, we proposed a new type superconducting power supply, i.e., linear type magnetic flux pump (LTMFP). The LTMFP mainly consists of DC bias coil, 3-phase AC coil and superconducting Nb foil. The compensating current in closed superconductive circuit can be easily controlled by the intensity of 3-phase AC current and its frequency. In this study, it has been investigated that the flux pump can effectively charge the current for various frequencies according to the different load magnets.

  • PDF

E-beam 조사하에서 유리의 전하 측정 (Charge Accumulation in Glass under E-beam irradiation)

  • 김대열;최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.268-269
    • /
    • 2008
  • Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples.

  • PDF

플라즈마 중합법에 의한 유기 감광체 박막의 제조와 광전도 특성 (Preparation and Photo Conducting Characteristics of Plasma Polymerized Organic Photorecepter)

  • 박구범
    • 전자공학회논문지T
    • /
    • 제36T권3호
    • /
    • pp.19-25
    • /
    • 1999
  • 플라즈마 중합법과 dip-coating법에 의해 이층형 유기 감광체를 제조하였다. 알루미늄 기판위에 장벽 층으로 Al₂O₃막을 만들었고, 전하 생성층으로 H₂ phthalocyanine(H₂Pc)를, 전하 수송층으로는 Poly 9-Vinylcarbazole을 채택하여 CGL/CTL의 이층 구조가 되도록 하였다. 플라즈마 중합법과 진공 증착법에 의해 각각 H₂ phthalocyanine 박막을 제조하여 흡광 특성을 검토한 결과 진공 증착막의 경우 613.6[nm]와 694.8[㎚]에서 흡수 피크가 관찰되었으나 플라즈마 중합막에서는 600-700[㎚]사이에서 완만한 피크가 관찰되었다. PVCz막의 표면전위는 인가한 코로나 방전 전압과 PVCz의 두께가 증가함에 따라 증가하였고, 암 감 쇠 특성과 광 감쇠 시간 그리고 잔류 시간도 PVCz의 두께의 증가와 함께 증가하였다. 15[㎛] 두께의 PVCz의 표면 전하량을 계산한 결과, 인가 전위 -600[V]에서 134[nc/㎠]이었으며 H₂Pc의 전하 생성 효율은 0.034이었다.

  • PDF

폴리이미드 박막의 공간전하현상 및 수분의 영향 (Space Charge Phenomena in Polyimide Films and Effects of Absorbed Water)

  • 윤주호;최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.82-85
    • /
    • 2008
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

폴리이미드 박막의 공간전하현상 (Space Charge Phenomena in Polyimide Films)

  • 윤주호;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.311-312
    • /
    • 2007
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

Epoxy 절연재료이 표면특성에 미치는 수분처리의 영향 (Effects of Water Treating on Surface Properties of Epoxy Insulation Materials)

  • 임경범;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권10호
    • /
    • pp.553-558
    • /
    • 2000
  • This paper deals with change of contact angle, surface potential decay, surface resistivity and XPS of water-treated epoxy insulator. From the experimental results on the contact angle was reduced from $74^{\circ}$to $24^{\circ}$ due to the formation of polar hydroxyl groups on surface which was associated with intermolecular reaction between epoxy chains of three-dimensional network structure and water molecules. From the experimental results in the surface potential decay of water treated-samples, it was found that the accumulation of charge is decreased and the surface potential decay time is shortened by the interaction of polar hydroxyl groups induced on the treated surface as the increment of treatment time. The positive charging on the treated surface compared with negative charging is relatively lowered by the induction of polar hydroxyl groups. The surface resistivity was changed from $10^{15}[{\Omega}/cm^2$] to $10^{12}[{\Omega}/cm^2$] caused by water treatment. From XPS, it was found that the changes affected by the surface degradation of epoxy were caused by the generation of carboxyl groups through the chain decomposition and recombination with oxygen molecules in the air.

  • PDF