• Title/Summary/Keyword: Charge decay

Search Result 91, Processing Time 0.031 seconds

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

The Characteristics of Potential Decay on the Corona Electrified Composite Insulating Material by Surface Condition (코로나 대전된 복합절연재료의 표면상태가 전위감쇠에 미치는 영향)

  • 황명환;정재희;조한구;송진호;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.65-69
    • /
    • 1997
  • Especially, Fiber glass Reinforced Plastics(FRP) is the best composite insulating material which has been so far. Therefore, it's worthy of notice to investigate on the corona electrified composite insulating material by surface condition. And then some other materials will be focussed on. In this study, charge decay were measured with charging-time and grid voltage on FRP composite material surface in order to analyze the mechanism. As a result we have studied that the way of the composite glass fiber(GF) and Polymer and the condition of the contaminated surface was different. In case of the GF is mixed with vertical, charge decay speed is fast because the charge is easily leaked. On the other hand, the surface charge decay speed is depend on conductive or insulated of the contaminant.

  • PDF

The characteristics of wall charge on the dependence of aging time in an AC Plasma Display Panel

  • Kim, Bhum-Joon;Cho, Hyung-Joon;Lee, Seung-Hun;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.710-713
    • /
    • 2003
  • The wall charge is major factor to determine the discharge characteristics. The minimum sustain voltage related to the wall charge decay were investigated as a function of aging time in AC plasma display panel. For the long time scale, the wall charge decay time is dependent on the aging time. The inverse time scale of the wall charge decay has the maximum value at around 3 hours aging time and then fell down.

  • PDF

Decay Process of Charge Distribution in E-beam Irradiated Polymers (전자빔 조사 폴리머의 전자 분포의 축퇴 과정)

  • Choi, Yong-Sung;Kim, Hyung-Gon;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.69-72
    • /
    • 2008
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

Decay Process of Charge Distribution in E-Beam Irradiated Polymers (E-빔 조사된 폴리머의 전하 분포의 축퇴 과정)

  • Yun, Ju-Ho;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.329-330
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

The Charge decay characteristics of Polymer surface by Corona discharge (코로나 하전한 고분자의 표면전하감쇄)

  • Lee, B.S.;Kim, Y.B.;Park, J.K.;Kim, J.S.;Lee, J.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1156-1158
    • /
    • 1995
  • Charge decay, thermally stimulated current(TSC), charging and discharging currents(I) are measured for negatively corona-charged polymers. In this study, we will make an experiment in charge decay on polymer surface, TSC, polarity effect and the others in order to analysis it's mechanism. Especially polyvinylidene fluoride(PVDF) film is the best functional material which has been so far. Therefore, It's worthy of notice to investigate it's characteristic. And then some other functional polymers will be focused on. An experimental result was missed out for the shortage of setting. So, this thesis will be explained on the theory and direction of reseach hereafter.

  • PDF

The Study on Potential Characteristics and Corona Discharge of Composite Insulating Material (복합절연재료 FRP의 코로나 대전파 전위감쇄특성에 관한 연구)

  • 이백수;신태현;김진식;강대하;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.365-368
    • /
    • 1995
  • Charge decay, thermally stimulated current (TSC), charging and discharging currents(I) are measured for corona-charged composite insulating materials. In this study, We will make an experiment in charge decay on composite material surface, TSC, polarity effect and the others in order to analysis its mechanism. Especially, Fiber glass Reinforced Plastics(FRP) is the best composite material which has been so far. Therefore, Its worthy of notice to investigate its characteristic. And then some other materials will be focused on. This experiment measured characteristic of charge decay, dependence of discharging-time and other electrostatic characteristics on FRP.

  • PDF

A Research Trend on Space Charge Analysis in Polymer Irradiated by Electron Beam (온도 상승시에 전자빔 조사된 폴리머내의 전하 분포의 축퇴 현상 연구 동향)

  • Ko, Sung-Min;Kim, Nam-Yong;Kim, Dae-Yeol;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1992-1993
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

Effect of Surface Charge in Hydrophobicity of Insulating Material and Decay of Surface Voltage after Corona Charging

  • Huh, Chang-Su;Youn, Bok-Hee;Seo, You-Jin;Hwang, Sun-Mook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.1-5
    • /
    • 2003
  • This paper presented the effects of accumulation of surface charges on hydrophobicity level and the surface states of silicone polymer used for outdoor insulator treated by ultraviolet irradiation and corona discharge through measuring surface voltage decay of a corona-charged specimen were investigated. The surface resistivity by the method of the surface potential decay was compared with the value by the three electrodes methods. From this study, it was found that the accumulation of surface charges above a critical surface voltage on silicone insulating materials could lead to the temporary loss of surface hydrophobicity. In addtion, uv stress lead to a longer decay time of surface charges. We could conclude that the effects of surface charges on hydrophocity level and the changes of surface state by various artificial treatments were understood through a trend of surface potential decay.

  • PDF

Decay and diffusion characteristic of electron and ion surface charges on MgO

  • Syn, Ho-Jung;Jeong, Dong-Cheol;Lee, Tae-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.377-380
    • /
    • 2008
  • In this work, we measured the spatiotemporal surface charge distribution by the longitudinal electro-optic amplitude modulation method with BSO single crystal to investigate the decay and diffusion characteristics of surface charges in three types of MgO. The speed of decay and diffusion of two different kinds doped MgO is compared with those of pure MgO. The difference in the characteristics of the decay and diffusion between the electron and ion surface charges is investigated separately. We found that the rate of ion decay is the major factor that makes the difference of the temporal variation of wall voltage among different types doped MgO.

  • PDF