• Title/Summary/Keyword: Charge coupled device

Search Result 237, Processing Time 0.046 seconds

Sensitivity Improvement Method for Color Capture Device At Low Illumination Conditions (Color Capture Device의 저조도 감도 향상 방안)

  • Kim, Il-Do;Jun, Jae-Sung;Choi, Byung-Sun;Park, Sahng-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.235-236
    • /
    • 2007
  • CCD(Charge-Coupled Device) 혹은 CMOS (Complementary Metal Oxide Semiconductor)와 같은 소자를 이용하여 빛을 전기적 신호인 Image로 재구성하는 촬상소자(Color Capture Device)는 촬영환경이 어두워지면 Dynamic Range가 작아지고, Noise가 상대적으로 심해진다[1][2]. 본 논문에서는 촬영 환경이 어두울 때, Resolution을 Preserving하는 Pixel Pitch가 큰 촬상 소자와 Motion Blur를 억제하는 Exposure Time이 긴 촬상 소자의 조합을 신호처리로 구현하여, 신호의 Power를 향상시켜 Dynamic Range를 키우고 Noise의 Boost-up을 억제하여 SNR(Signal to Noise Ratio)을 향상시키는 방식으로, 촬상 장치의 감도를 향상시켜 화질을 개선하는 방법을 제안한다.

  • PDF

Color Filter Array Interpolation Method Using Neural Networks (신경망을 이용한 Color Filter Array 보간 기법)

  • 고진욱;이철희
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.242-245
    • /
    • 2000
  • In this paper, we present a color interpolation technique based on artificial neural networks for a single-chip CCD (charge-coupled device) camera with a Bayer color filter array (CFA). Single-chip digital cameras use a color filter array and an interpolation method in order to regenerate high quality color images from sparsely sampled images. We applied 3-layer feedforward neural networks in order to interpolate missing pixel from surrounding pixels. And we compared the proposed method with conventional interpolation methods such as the proposed interpolation algorithm based on neural networks provides a better performance than the conventional interpolation algorithms.

  • PDF

Data extraction from distorted image in holographic data storage (홀로그래픽 데이터 저장 장치에서 왜곡된 이미지로부터의 데이터 추출)

  • 전승준;양병춘;이병호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.60-61
    • /
    • 2000
  • 홀로그래픽 데이터 저장 장치(holographic data storage)는 1960년대에 이미 아이디어가 출현하였고, 1990년대에 들어서 SLM(spatial light modulator)과 CCD(charge coupled device) 등 관련 기술의 발달과 함께 향후 늘어날 대용량 저장 장치 시장에 대한 전망 등에 힘입어 주목받기 시작하였다. 홀로그래픽 데이터 저장 장치의 중요한 장점은 대용량의 정보를 고속으로 처리할 수 있고, 특히 페이지 단위로는 병렬 접근이 가능하다는 것인데, 이를 위해서 반드시 해결되어야 할 것이 픽셀 매치(pixel-match)이다. (중략)

  • PDF

Development of Measuring System for Camera Lens Resolution Based on the MTF Performance (MTF 측정에 의한 카메라 렌즈 해상력 검사 시스템 개발)

  • 박희재;신호승;노영훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.629-634
    • /
    • 2000
  • This System is developed for the estimation of the Camera Lens Resolution. Signal data proportional to light intensity is obtained and sampled from the 2D CCD. Based on the measured signal. the MTF charateristcs of a camera lens are measured. We could measure the sagittal and tangential MTF in the on and off-axis at the same time. The automatic measurig methods for optimal image plane, magnification, and best marginal direction of test lens are presented.

  • PDF

Real Time Spectroelectrochemical Experiments with a Multichannel Detector

  • Sun-Il Mho;Sally N. Holer;Bum-Soo Kim;Su-Moon Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.739-743
    • /
    • 1994
  • A spectroelectrochemical system assembled with a white light source, bifurcated optical fiber, Oriel Multispec spectrograph, and a charge-coupled device (CCD) detector is described. The system is shown to be capable of acquiring a whole spectrum in the spectral range of 290-800 nm in 25 ms or a longer period during electrochemical experiments at reflective working electrodes such as platinum or mercury. The utility of the system in studying electrochemical reactions during the potential scan, galvanostatic electrolysis, or after the potential step is demonstrated.

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

Motion of Conductive Spherical Particle under Uniform Electric Field (평등전계에서 도전성 구형 입자의 운동)

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

Study on Biophoton Emission from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K (한국 당귀, 중국 당귀, 일본 당귀의 생체광자(Biophoton) 방출 비교 연구)

  • Park, Wan-Su;Lee, Chang-Hoon;Soh, Kwang-Sup;Lee, Young-Jong;Lee, Choong-Yeo;Lee, Tae-Hee;Kim, Youn-Sub;Kim, Do-Hoon
    • The Korea Journal of Herbology
    • /
    • v.22 no.4
    • /
    • pp.95-100
    • /
    • 2007
  • Objectives : The purpose of this study is to investigate the delayed luminescence-biophoton emission from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K These three species of Genus Angelica are now used as 'Danggui' in Traditional Korean Medicine. Methods : Randomly selected samples from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K were radiated with 150 W metal halide lamp for 1 minute. After radiation, biophoton emissions of each sample were detected by electron multiplication-charge coupled device camera. The detected biophoton image was calculated with unit of counts per pixel. Results : The average and maximum biophoton emissions of delayed luminescence with electron multiplication ratio of ${\times}150$ and ${\times}250$were distinguished significantly between Angelica gigas N. and the other two species. Conclusions : These results suggest that biophoton imaging of roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K. could become the meaningful method for the study of differentiation between root of Angelica gigas N. and the other two species, Angelica sinensis D. and Angelica acutiloba K.

  • PDF

Measurement Method and System of Optical Fiber-Based Beam Width Using a Reflective Grating Panel

  • Lee, Yeon-Gwan;Jang, Byeong-Wook;Kim, Yoon-Young;Kim, Jin-Hyuk;Kim, Chun-Gon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.175-178
    • /
    • 2011
  • An optical fiber-based beam width measurement technique is presented. The proposed system can be applied to the optical fiber industry in applications such as lensed fiber, optical fiber based laser beam source, and fiber optic sensor. The measurement system is composed of optical fiber, which is used as a transceiver, and a single grating panel which consists of a multi-reflection area with an even non-reflection area. The grating panel is used to vary the reflected light. When the widths of the reflection area and non-reflection area are larger than the optical beam width, the reflected light is varied at the interface between the reflection area and the non-reflection area by the movement of the grating panel. Experiments were conducted in order to verify the feasibility of the proposed technique. Multi-mode fiber combined with a collimator was selected as an emitter and a receiver, and the beam width measurement system was contrived. Subsequently, the proposed method and the system were verified by comparing the experimental results with the results of the conventional charge-coupled device technique.