• 제목/요약/키워드: Charge air pressure

검색결과 103건 처리시간 0.032초

직접분사 성층연소방식에서 수소 첨가에 의한 미연 탄화수소의 저감 (The Reduction of Unburned Hydrocarbons on the Direct-Injection Stratified-Charge Combustion Method by Hydrogen Addition)

  • 홍명석;김경석
    • 한국자동차공학회논문집
    • /
    • 제4권4호
    • /
    • pp.46-57
    • /
    • 1996
  • The direct injection stratified charge(DISC) engine enhances the fuel tolerance and the antiknock tendency. This enhanc3d antiknock tendency allows use of a higher compression ratio which results in higher thermal efficiency. But its actual utilization is prevented by high emission combustion time and wall quenching will be the main causes of increasing unburned hydrocarbons in DISC system. In order to solve this problem, small aount of hydrogen was added to the charging air or injected fuel. The effects of hydrogen addition were examined experimentally by radial fuel injection using a pancake-type constant volume bomb. In case of the hydrogen addition to the charge of air, the combustion the amount of hydrogen. In case of the hydrogen addition to the fuel, the combustion pressure was significantly increased.

  • PDF

입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향 (Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles)

  • 지준호;강석훈;황정호;배귀남
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.

R134a와 R152a 냉매를 이용한 자동차용 에어컨 시스템의 성능 비교 (Performance Comparison of Automotive Air conditioning System by using R134a and R152a)

  • 김종수;남수병;이대웅;유성연;김진혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.9-14
    • /
    • 2006
  • This study presented the feasibility of R152a refrigerant as an alternative of R134a which is used in the current automobile air conditioning system. The performance of air conditioning system installed in the actual vehicle was tested using the climate wind tunnel. The experiments were conducted at various refrigerant charge quantities and various driving conditions such as city traffic, highway traffic and parking. Same components and lubricant were used for both R134a and R152a system. The effects of air set values of thermal expansion valve on the performance were also investigated. In case of the R152a system, refrigerant charge quantity can be reduced about 20%, better performance and superior compressor durability is expected due to the lower discharge pressure compared to the R134a system.

  • PDF

예혼합 압축 착화 엔진용 고압 인젝터의 분무특성과 분사조건 최적화에 관한 기초 연구 (The basic study of spray characteristics and optimal fuel injection for high pressure injector in homogeneous charge compression ignition engine)

  • 류재덕;김형민;이기형;이창식
    • 한국분무공학회지
    • /
    • 제9권1호
    • /
    • pp.30-36
    • /
    • 2004
  • The purpose of this study was to investigate the fuel spray characteristics that made most important at an homogeneous air fuel mixture, in a common rail direct injection type HCCI engine. As a study conducted relation which a back pressure and injection pressure are influenced to air fuel mixture characteristics, we tried to offer date even through we select suitable to a HCCI engine running condition of the fuel injection condition. To accomplish the study, to measure a injection rate of common rail type injector and to visualize and simulate a fuel spray was conducted. From the result of injection rate, a common rail injector was confirmed to appear a initial delay of 0.3msec and a latter period delay of 0.7msec. Therefore, real injection duration was determined by about 0.5msec increasing. From the result of fuel spray, the spray penetration was proportional to 1/4 exponent of atmosphere pressure. An experimental equation was deduced from the spray penetration of spray visualization experiment and the relation of injection duration and penetration was estimated in HCCI engine using an experimental equation.

  • PDF

승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화 (Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles)

  • 지준호;강석훈;황정호;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Pressure and temperature change in air cylinders in charged or discharged case

  • Takeuchi, Masaaki;Kagawa, Toshiharu;Nomura, Naoki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.298-301
    • /
    • 1993
  • In pneumatic systems the temperature changes during operation owing to air compression or expansion, friction of air movement and friction between solid interface. The temperature change usually ha undesirable influence on process. To attain higher quality of pneumatics, studies in thermo-fluid dynamics is needed. This paper presents experimental results anti theoretical analysis on the temperature change by air charge and discharge to cylinders, which has no piston yet. The temperature increase by charge shows a strong, dependence on axial location along the cylinder, which is proved in theoretical analysis. The temperature decreases by discharge shows rather uniform in the cylinder, which is also proved by theory.

  • PDF

HFC152a 대체냉매를 이용한 자동차 냉방장치의 성능 최적화에 관한 연구 (Study of Performance Optimization as an Alternative Refrigerant HFC152a in a Mobile Air Conditioning System)

  • 이대웅
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.321-327
    • /
    • 2015
  • This study presents an HFC152a refrigerant air conditioner as an alternative to HFC134a, which is currently used in mobile air conditioning systems. Cool-down performance tests of an HFC152a air conditioning system were conducted and compared to a baseline HFC134a air conditioner. The experimental set-up consisted of a belt-driven compressor, a sub-cooled type condenser, an evaporator, and a block-type thermal expansion valve (TXV). A drop-in test was carried out on the mobile air conditioning system under various vehicle running speeds in a climate-controlled wind tunnel (CWT). Additionally, to optimize the HFC152a air conditioning system, the effects of the TXVs on the performance were studied. The results show that compared to the HFC134a air conditioning system, the refrigerant charge quantity was reduced by approximately 20%, the discharge pressure was reduced by about 350~430 kPa, and the air discharge temperature at vehicle running conditions was $0.5{\sim}1.5^{\circ}C$ lower. In addition, good compressor durability was expected due to the lower compression ratio.

직분식 예혼합 압축착화 디젤엔진의 운전조건과 연료조성에 따른 연소 및 배기 특성 (The Characteristics of Combustion and Exhaust Emission according to Operating Condition and Fuel Composition in a Direct Injection Type HCCI Diesel Engine)

  • 이기형;류재덕;이창식
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.10-16
    • /
    • 2004
  • The Homogeneous Charge Compression Ignition (HCCI) engine has advantage for reducing the NOx and P.M. simultaneously. Therefore, HCCI engine is receiving attention as a low emission diesel engine concept. This study was carried out to investigate the characteristics of combustion and exhaust emission for operating conditions in a direct injection type of HCCI engines such as supercharged and naturally aspirated using diesel fuel and additive. From the experimental result, we found that cool flame was always appeared and also it was difficult to control combustion characteristics by changing the injection timing in HCCI. In addition, at the lean air-fuel ratio and high speed range, it was observed that charging air pressure, additive or increasing intake air temperature is effective to increase combustion performance and reduce exhaust emission. We concluded that chemical reaction by the increasing intake air temperature or additive without physical improvement has limitation for reduction of exhaust emission.

태양광발전 방식의 자동차용 과급 장치의 성능 평가 (Performance Test of Supercharger for Vehicle using Solar Cell)

  • 고광호
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.942-948
    • /
    • 2011
  • The performance of a supercharger for vehicle using solar cell attached on the exterior of a car, an auxiliary battery, and an air compressor was evaluated in this study. This supercharger is composed of a solar cell of 40W, a battery of 60 Ah, an air compressor of 17 A, 8 $kgf/cm^2$ and an air tank of 8L. It takes about 6 days to charge the battery with the solar cell and the high pressure air of 8L can be supplied about 70 times to engine intake with this battery. The intake pressure increased by about 20~40% with this supercharger. The vehicle power and accelerating performance are enhanced by 87% and 50% each in the low speed range. But the performance improved little in the high speed range because of the rather constant flow rate of air supplied by this type of supercharger.

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.