• 제목/요약/키워드: Charge Coupled Device-Camera

검색결과 122건 처리시간 0.026초

팬터그래프-전차선로 접촉부 영상처리 기술 개발 (Development of Image Processing Technology for Interaction between Pantograph and Overhead Contact Wire)

  • 김형준;박영;조용현;조철진;김인철
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1084-1088
    • /
    • 2009
  • The measurement of dynamic stagger in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. This paper is introduces a non-contact optical-based measuring instrument of a catenary system in electric railways. The instrument is implemented by utilizing a CCD (Charge Coupled Device) camera installed on the roof of a vehicle for vision acquisition and image processing techniques including the Canny edge detector and the Hough transform to detect contact wires and calculate dynamic stagger. To check the validity of our approach for the intended application, we measured stagger of a overhead wire of a Korea Tilting Train (TTX). The non-contact optical-based measurement system proposed in this paper performs real-time stagger measurement of an activated high-voltage contact wire. By results of this paper, the instrument should be applied to assess performance and reliability of newly developed electric railway vehicles.

Reflectance water index를 이용한 참나무속 3종 낙엽의 함수량 추정 (Estimation of Water Content in Leaf Litter of Three Quercus Species by Reflectance Water Index)

  • 서계홍
    • 한국환경과학회지
    • /
    • 제27권4호
    • /
    • pp.275-279
    • /
    • 2018
  • Water status of intact plants has been optically estimated by measuring reflectance at the wavelengths 1,450 nm and 1,900 nm based on their signal strengths. Although another water band at 970 nm is considered to have very small signals, the band apparently lies within the detection range of inexpensive spectrometer and plain charge-coupled device (CCD) camera used in wild fire studies. However measurement of the reflectance at 970 nm has been rarely applied to estimate the water status of dead plant materials such as fallen branch, twig, and leaf. To test the possibility of applying water reflectance at 970 nm to estimate the water content (WC) in leaf litter, the reflectance in various WC values were measured in the leaf litter of three Quercus species (Q aliena, Q aliena, Q mongolica, and Quercus variabilis). The results showed that the WC in the leaf litter can be determined by reflectance water index (WI) in the three Quercus species ($WC=1,450{\times}WI-1,378.8$, r=0.865). However, there was no interaction effect in the relationship between WI and WC among the litter of the three Quercus species.

KIERDISH II 태양열 집광시스템의 플럭스밀도 분포 (Flux Density Distribution of the Dish Solar Concentrator (KIERDISH II))

  • 강명철;강용혁;유성연
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.11-18
    • /
    • 2004
  • A solar concentrator, named KIERDISH II, was built at KIER in order to investigate the feasibility of high temperature solar energy application system. The constructed concentrator is a dish type solar concentrator with a focal length of 4.68m and a diameter of 7.9m. To successfully operate KIERDISH II, optimal design of the absorber is very important and flux density distribution has to be known. The focal flux density distribution on the receiver was measured. We have observed the shape and size of flux images and evaluated percent power within radius. Flux density distribution is usually measured by a CCD(charge coupled device) camera and a radiometer. In this paper we present a flux mapping method to estimate the characteristic features of the flux density distribution in the focal region of solar concentrator. The minimum radius of receiver is found to be 0.15m and approximately 90% of the incident radiation is intercepted by receiver aperture.

화상처리에 의한 Gas Tungsten Arc 용접에서의 용융지폭제어에 관한 연구 (A Study of Weld Pool width Control in Gas Tungsten Arc Welding Using the Digital Image Processing)

  • 김동철;이세헌;엄기원
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2760-2769
    • /
    • 1996
  • The feedback control systems of welding process using visual information can improve weld qualities. However, it is very difficult to get the visual information of weld pool since the light intensity of welding arc is much stronger than that of the weld pool. To explore the possibility of extending the capability of automatic welding machines, a study of a closed loop controlled welding system consisted of a GTA welding machine, a vision system, a stepping motor system and a digital computer was undertaken. Particularly, in this system, a CCD camera with a long wavelength pass filter was used to get a better weld pool image. Subsequently, an image analysis technique has been developed to measure the weld pool width. Using this weld pool width measurement, a colsed loop control system adjusted welding speed to maintain a constant weld pool width.

Ar/N2 혼합가스 비율에 따른 대기압 저온 플라즈마제트의 플라즈마 전파 속도 및 전자 온도 조사

  • 한국희;김윤중;진세환;김현철;;조광섭
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.247.2-247.2
    • /
    • 2014
  • 플라즈마 전파 속도와 전자 온도를 조사하기 위해 ICCD카메라(Intensified Charge-Coupled Device Camera, 이하 ICCD)를 이용하여 대기압 저온 플라즈마제트의 방전 이미지를 촬영하였다. 사용된 플라즈마 제트 장치는 유리관 안에 주사기 바늘형 전극이 들어있는 형태이다. 전극의 내경은 1.3 mm, 외경은 1.8 mm, 총 길이는 39.0 mm이며 재질은 스테인레스강이다. 유리관의 내경은 2.0 mm, 외경은 2.4 mm, 총 길이는 80.0 mm이다. 입력 전압은 3.0 kV이며 구동 주파수는 40 kHz이다. 아르곤과 질소의 혼합가스 비율은 각각 100:1, 98:2, 95:5을 사용하였으며 총 가스유량은 400 sccm이다. 각각의 비율별로 군속도는 267 km/s, 305 km/s, 313 km/s이며 이온 음향 속도는 1.16 km/s, 1.24 km/s, 1.25 km/s이고, 전자 온도는 0.55 eV, 0.63 eV, 0.65 eV로 관찰되었다.

  • PDF

Diagnostics of Magnetron Sputtering Plasmas: Distributions of Density and Velocity of Sputtered Metal Atoms

  • Sasaki, Koichi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.98-99
    • /
    • 2012
  • Deposition of thin films using magnetron sputtering plasmas is a well-developed, classical technology. However, detailed investigations using advanced diagnostics are insufficient in magnetron sputtering, in comparison with plasma-aided dry etching and plasma-enhanced chemical vapor deposition. In this talk, we will show examples of diagnostic works on magnetron sputtering employing metal targets. Diagnostic methods which have fine spatial resolutions are suitable for magnetron sputtering plasmas since they have significant spatial distributions. We are using two-dimensional laser-induced fluorescence spectroscopy, in which the plasma space is illuminated by a tunable laser beam with a planer shape. A charge-coupled device camera with a gated image intensifier is used for taking the picture of the image of laser-induced fluorescence formed on the planer laser beam. The picture of laser-induced fluorescence directly represents the two-dimensional distribution of the atom density probed by the tunable laser beam, when an intense laser with a relatively wide line-width is used. When a weak laser beam with a relatively narrow linewidth is used, the laser-induced fluorescence represents the density distribution of atoms which feel the laser wavelength to be resonant via the Doppler shift corresponding to their velocities. In this case, we can obtain the velocity distribution function of atoms by scanning the wavelength of the laser beam around the line center.

  • PDF

임피던스 법을 이용한 두피 상태 추정에 관한 연구 (A Study for Estimation of Scalp Condition by Impedance)

  • 심명헌;최한윤;정인철;김기원;윤형로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.471-472
    • /
    • 2007
  • The scalp is skin tissue for skull-protection and roots for hair growth. Therefore continuous monitoring of scalp condition is essential for hair management. However, the equipments for existent are inconvenient to use because of focus tremor and external factors(Hair Gel, Wax, accessories and so on). Furthermore there is a problem to use an expensive optical devices like CCD (Charge Coupled Device) camera or lens of 200 - 1000 magnification. It causes a difficulty of using those equipment. We design the special electrode(length 5.65mm, diameter 0.8mm of needle shape) and the impedance system(1kHz, 78uA). Tn this paper, we can measure scalp impedance with our system. Moreover, we find the possibility of classifying scalp condition with measured impedance values. For the classification of scalp condition, we used ARAMO-TS as an imaging system. In conclusion, the problem of existent devices could be improved using these method. It also has a benefit of continuous monitoring of scalp condition.

  • PDF

Fast High-throughput Screening of the H1N1 Virus by Parallel Detection with Multi-channel Microchip Electrophoresis

  • Zhang, Peng;Park, Guenyoung;Kang, Seong Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1082-1086
    • /
    • 2014
  • A multi-channel microchip electrophoresis (MCME) method with parallel laser-induced fluorescence (LIF) detection was developed for rapid screening of H1N1 virus. The hemagglutinin (HA) and nucleocapsid protein (NP) gene of H1N1 virus were amplified using polymerase chain reaction (PCR). The amplified PCR products of the H1N1 virus DNA (HA, 116 bp and NP, 195 bp) were simultaneously detected within 25 s in three parallel channels using an expanded laser beam and a charge-coupled device camera. The parallel separations were demonstrated using a sieving gel matrix of 0.3% poly(ethylene oxide) ($M_r$ = 8,000,000) in $1{\times}$ TBE buffer (pH 8.4) with a programmed step electric field strength (PSEFS). The method was ~20 times faster than conventional slab gel electrophoresis, without any loss of resolving power or reproducibility. The proposed MCME/PSEFS assay technique provides a simple and accurate method for fast high-throughput screening of infectious virus DNA molecules under 400 bp.

Dynamic characteristics between waves and a floating cylindrical body connected to a tension-leg mooring cable placed in a simulated offshore environment

  • Song, Juhun;So, Soo-Hyun;Lim, Hee-Chang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.375-385
    • /
    • 2016
  • Given the rapid progress made in understanding the dynamics of an offshore floating body in an ocean environment, the present study aimed to simulate ocean waves in a small-sized wave flume and to observe the motion of a cylindrical floating body placed in an offshore environment. To generate regular ocean waves in a wave flume, we combined a wave generator and a wave absorber. In addition, to precisely visualise the oscillation of the body, a set of light-emitting diode illuminators and a high-speed charge-coupled device camera were installed in the flume. This study also focuses on the spectral analysis of the movement of the floating body. The wave generator and absorbers worked well to simulate stable regular waves. In addition, the simulated waves agreed well with the plane waves predicted by shallow-water theory. As the period of the oncoming waves changed, the movement of the floating body was substantially different when tethered to a tension-leg mooring cable. In particular, when connected to the tension-leg mooring cable, the natural frequency of the floating body appeared suddenly at 0.391 Hz as the wave period increased.

용광로 연소대 관리시스템 개발 (Development of combustion zone monitoring system for a blast furnace)

  • 최태화
    • 제어로봇시스템학회논문지
    • /
    • 제3권3호
    • /
    • pp.318-322
    • /
    • 1997
  • A prototype of combustion zone monitoring system as been developed and installed into tuyeres of the blast furnace. The system consists of CCD(charge coupled device) cameras, sonic flow meters, an image processor and a personal computer. The personal computer collects raceway luminance data and operational data from the image processor that is connected to the color CCD camera from the blast furnace process computer, respectively. In addition, the sonic flow meters supply coal injection rate data to the personal computer. Then, the personal computer evaluates the combustion conditions with the raceway inspection algorithm. This integrated monitoring system allows us to detect abnormal raceway conditions and the clogging status of coal injection pipe. The image processing techniques of the system enable us to effectively monitor unburnt coal sticking to tuyere tip and injection lance wear conditions. Such a developed system ensures rapid and precise raceway inspection. The image processing capability of the system has helped operator to early detect both the unburnt coal sticking problem and the errosion problem of injection lance. Furthermore, the system could control the abnormal raceway condition based the the analysis results obtained from combustion monitoring.

  • PDF