• Title/Summary/Keyword: Charge Collection Efficiency

Search Result 57, Processing Time 0.029 seconds

Effective Interfacial Trap Passivation with Organic Dye Molecule to Enhance Efficiency and Light Soaking Stability in Polymer Solar Cells

  • Rasool, Shafket;Zhou, Haoran;Vu, Doan Van;Haris, Muhammad;Song, Chang Eun;Kim, Hwan Kyu;Shin, Won Suk
    • Current Photovoltaic Research
    • /
    • v.9 no.4
    • /
    • pp.145-159
    • /
    • 2021
  • Light soaking (LS) stability in polymer solar cells (PSCs) has always been a challenge to achieve due to unstable photoactive layer-electrode interface. Especially, the electron transport layer (ETL) and photoactive layer interface limits the LS stability of PSCs. Herein, we have modified the most commonly used and robust zinc oxide (ZnO) ETL-interface using an organic dye molecule and a co-adsorbent. Power conversion efficiencies have been slightly improved but when these PSCs were subjected to long term LS stability chamber, equipped with heat and humidity (45℃ and 85% relative humidity), an outstanding stability in the case of ZnO/dye+co-adsorbent ETL containing devices have been achieved. The enhanced LS stability occurred due to the suppressed interfacial defects and robust contact between the ZnO and photoactive layer. Current density as well as fill factors have been retained after LS with the modified ETL as compared to un-modified ETL, owing to their higher charge collection efficiencies which originated from higher electron mobilities. Moreover, the existence of less traps (as observed from light intensity-open circuit voltage measurements and dark currents at -2V) are also found to be one of the reasons for enhanced LS stability in the current study. We conclude that the mitigation ETL-surface traps using an organic dye with a co-adsorbent is an effective and robust approach to enhance the LS stability in PSCs.

A Preponderant Enhancement of Conversion Efficiency by Surface Coating of $SnO_2$ Nanoparticles in Organic MK-2 Dye Sensitized Solar Cell

  • Son, Dae-Yong;Lee, Chang-Ryul;Park, Nam-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.218-218
    • /
    • 2012
  • Nanocrystalline $SnO_2$ colloids are synthesized by hydrolysis of $SnCl_4{\cdot}5H_2O$ in aqueous ammonia solution. The synthesized $SnO_2$ nanoparticles with ca. 15 nm in diameter are coated on a fluorinedoped thin oxide (FTO) conductive substrate and heated at $550^{\circ}C$. The annealed $SnO_2$ film is treated with aqueous $TiCl_4$ solution, which is sensitzied with MK-2 dye (2-cyano-3-[5'''-(9-ethyl- 9H-carbazol-3-yl)-3',3'',3''',4-tetra-n-hexyl-[2,2',5',2'',5'',2''']-quater thiophen-5-yl]). Compared to bare $SnO_2$ film, the conversion efficiency is significantly improved from 0.22% to 3.13% after surface treatment of $SnO_2$ with $TiCl_4$, which is mainly due to the large increases in both photocurrent density from 1.33 to $9.46mA/cm^2$ and voltage from 315 to 634 mV. It is noted that little change in the amount of the adsorbed dye is detected from 1.21 for the bare $SnO_2$ to $1.28{\mu}mol/cm^2$ for the $TiCl_{4-}$ treated $SnO_2$. This indicates that the photocurrent density increased by more than 6 times is not closely related to the dye loading concentration. From the photocurrent and voltage transient spectroscopic studies, electron life time increases by about 13 order of magnitude, whereas electron diffusion coefficient decreases by about 3.6 times after $TiCl_4$ treatment. Slow electron diffusion rate offers sufficient time for regeneration kinetics. As a result, charge collection efficiency of about 40% before $TiCl_4$ treatment is improved to 95% after $TiCl_4$ treatment. The large increase in voltage is due to the significant increase in electron life time, associated with upward shift of fermi energy.

  • PDF

An Analysis of Work Stress of Physical Therapist and Reaction (물리치료사의 업무 스트레스 현황과 대응수준 -부산지역을 중심으로-)

  • Dong, Jong Ick;Ryu, Hwang Gun;Bae, Sung-Kwon
    • The Korean Journal of Health Service Management
    • /
    • v.2 no.1
    • /
    • pp.37-55
    • /
    • 2008
  • This study aims to enhance work efficiency and satisfaction by offering data that make a physical therapist cope with stress coming from the job efficiently by identifying and analyzing the job satisfaction and work stress perceived by a physical therapist, and the level of reaction of a physical therapist. The study distributed survey questionnaires to 300 physical therapists working in medical institutions in Busan via mail and by visit from March 3, 2007 by selecting them simply and randomly from the physical therapist list, and collected the questionnaires by March 20, 2007, 103 respondents were working at 17 general hospitals including a university hospital, 65 respondents at 12 medical centers, and 79 respondents at 39 doctor's offices. The study collected 251 copies, which showed the collection rate of 83.7%, and analyzed 247 copies (82.3%) excluding 4 copies of insincere answers. As a research tool for measuring job satisfaction the study used a tool employed for research into the job satisfaction of physical therapists who work at medical institutions in Gwangju, Jeonnam, and Jeonbuk by Kim Hee-Gwon(1992) and research regarding job satisfaction by Jeong Jeong-Hee(2004) as well as research regarding the factors of job satisfaction by Flippo(1980) & Seberhagen(1970) after adjusting the research tools to the purpose of the study. Also for questions about work stress, the study employed nurses' job stress measurement tool developed by Kim Mae-Ja and em Mi-Ok(1984) by modifying the tool to the purpose of the study, and for a measurement tool for reaction to stress, the study used a tool employed for research into reaction to stress of nurses at general hospitals by Choi Eun-Deok(2005) without modification. For data analysis, the study used the SPSS12.0 as a statistical method, and then used t-test or ANOVA for verifying actual numbers, percentile, average :score, standard deviation, rank, and difference. Also, the study conducted which is a post-test method for variables that show a significant difference at the level of p<.05 level after the analysis. The findings include the following. 1) The respondents' job satisfaction score was 3.21 points on the average (out of 5 full points). The peer relationship ranked the highest, posting 4.02 points on the average, and the job satisfaction with rewards was proven the lowest, posting 2.51 points. For the job satisfaction level by characteristics, there were significant differences (p<.05) in gender, hospital type, weekly working hours, monthly working days, number of patients per day, department in charge of therapy, and number of peers, and there was no significant difference in characteristics other than that. 2) The respondents' work stress score was 2.72 points (out of 5 full points) on the average. The respondents were shown to be under the highest stress when they suffered from excessive workload, posting 3.49 points on the average, and they were shown to be under the least stress when they had a conflict with peers at another department, recording 1.90 points on the average. for the job stress level by the characteristics of job, there was a significant difference in the reflection of job assessment(p<.05). 3) 1n respondents' reaction to stress, most of them were shown to make efforts in coping with stress, posting 2.80 points (out of 5 full points). For their experience of being wider stress, they answered that 'they felt depressed (2.85 points)" for their experience of coping with stress, they answered that 'they were indifferent to it or thought about something else' (2.62 points). Also, for their efforts in coping with stress, they answered that 'they were motivated to remove their strain by taking leave, playing, or using their preferences' (3.52 points), which ranked higher. For the level of reaction to stress by characteristics, there were significant differences by age, gender, marital status, total service years as a physical therapist, monthly working days, and department in charge of therapy(p<.05). It is necessary to offer correct information by conducting an in-depth analysis of the stressful situations of physical therapists who exert efforts in rehabilitating patients at hospitals by factor, and seeking management plans based on the research results. Also, it is necessary to develop a program for coping with stress efficiently for removing stress and to conduct research into the understanding and cooperation of administrators and persons in charge of physical therapists for reducing physical therapists' stress at hospitals.

  • PDF

Performances and Electrical Properties of Vertically Aligned Nanorod Perovskite Solar Cell

  • Kwon, Hyeok-Chan;Kim, Areum;Lee, Hongseuk;Lee, Eunsong;Ma, Sunihl;Lee, Yung;Moon, Jooho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.429-429
    • /
    • 2016
  • Organolead halide perovskite have attracted much attention over the past three years as the third generation photovoltaic due to simple fabrication process via solution process and their great photovoltaic properties. Many structures such as mesoporous scaffold, planar heterojunction or 1-D TiO2 or ZnO nanorod array structures have been studied to enhance performances. And the photovoltaic performances and carrier transport properties were studied depending on the cell structures and shape of perovskite film. For example, the perovskite cell based on TiO2/ZnO nanorod electron transport materials showed higher electron mobility than the mesoporous structured semiconductor layer due to 1-D direct pathway for electron transport. However, the reason for enhanced performance was not fully understood whether either the shape of perovskite or the structure of TiO2/ZnO nanorod scaffold play a dominant role. In this regard, for a clear understanding of the shape/structure of perovskite layer, we applied anodized aluminum oxide material which is good candidate as the inactive scaffold that does not influence the charge transport. We fabricated vertical one dimensional (1-D) nanostructured methylammonium lead mixed halide perovskite (CH3NH3PbI3-xClx) solar cell by infiltrating perovskite in the pore of anodized aluminum oxide (AAO). AAO template, one of the common nanostructured materials with one dimensional pore and controllable pore diameters, was successfully fabricated by anodizing and widening of the thermally evaporated Al film on the compact TiO2 layer. Using AAO as a scaffold for perovskite, we obtained 1-D shaped perovskite absorber, and over 15% photo conversion efficiency was obtained. I-V measurement, photoluminescence, impedance, and time-limited current collection were performed to determine vertically arrayed 1-D perovskite solar cells shaped in comparison with planar heterojunction and mesoporous alumina structured solar cells. Our findings lead to reveal the influence of the shape of perovskite layer on photoelectrical properties.

  • PDF

The Distribution and Patient Care in Radiography for Emergency Outpatients (응급환자의 방사선영상검사 분포 및 Patient Care)

  • Lee, Hwan-Hyung;Kang, Won-Han
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

Fabrication and Characterization of Lead Oxide (PbO) Film for High Efficiency X-ray Detector (고효율 X선 검출기 적용을 위한 PbO 필름 제작 및 특성 연구)

  • Cho, Sung-Ho;Kang, Sang-Sik;Choi, Chi-Won;Kwun, Chul;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.329-329
    • /
    • 2007
  • Photoconductive poly crystalline lead oxide coated on amorphous thin film transistor (TFT) arrays is the best candidate for direct digital x-ray detector for medical imaging. Thicker films with lessening density often show lower x-ray induced charge generation and collection becomes less efficient. In this work, we present a new methodology used for the high density deposition of PbO. We investigate the structural properties of the films using X-ray diffraction and electron microscopy experiments. The film coatings of approximately $200\;{\mu}m$ thickness were deposited on $2"{\times}2"$ conductive-coated glass substrates for measurements of dark current and x-ray sensitivity. The lead oxide (PbO) films of $200\;{\mu}m$ thickness were deposited on glass substrates using a wet coating process in room temperature. The influence of post-deposition annealing on the characteristics of the lead oxide films was investigated in detail. X-ray diffraction and scanning electron microscopy, and atomic force microscopy have been employed to obtain information on the morphology and crystallization of the films. Also we measured dark current, x-ray sensitivity and linearity for investigation of the electrical characteristics of films. It was found that the annealing conditions strongly affect the electrical properties of the films. The x-ray induced output charges of films annealed in oxygen gas increases dramatically with increasing annealing temperatures up to $500^{\circ}C$ but then drops for higher temperature anneals. Consequently, the more we increase the annealing temperatures, the better density and film quality of the lead oxide. Analysis of this data suggests that incorporation and decomposition reactions of oxygen can be controlled to change the detection properties of the lead oxide film significantly. Post-deposition thermal annealing is also used for densely film. The PbO films that are grown by new methodology exhibit good morphology of high density structure and provide less than $10\;pA/mm^2$ dark currents as they show saturation in gain (at approximate fields of $4\;V/{\mu}m$). The ability to operate at low voltage gives adequate dark currents for most applications and allows voltage electronics designs.

  • PDF

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.