• 제목/요약/키워드: Characteristics Toxicity

검색결과 413건 처리시간 0.026초

흡입독성평가를 위한 비부노출 챔버의 유동흐름 특성 (Characteristics of flow field of nose-only exposure chamber for inhalation toxicity evaluation)

  • 노학재;봉춘근;봉하경;김용구;조명행;김상화;김대성
    • 한국입자에어로졸학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2016
  • In this work, we evaluated the characteristics of flow field and uniformity of the nose-only exposure chambers for the inhalation toxicity test. Computational fluid dynamics (CFD) modeling was carried out to demonstrate uniformity of the nose-only exposure chambers. Because it is very important in the inhalation toxicity experiments that test materials are distributed uniformly to each holder of the chamber. The test was done with these 3 types of chamber with different form to develop inhalation toxicity evaluation system, easy-to-operate system among exposure chamber used for evaluating inhalation toxicity of environmental chemical mixtures. Through CFD interpretation, nose-only exposure chamber was made with the selection of the optimal conditions. For its evaluation, one type of fragrance was selected and measured particle size distribution of each port. The gene becoming luminous to green fluorescence was combined with GPT-SPE, a type of tGFP vector, to be inhaled to the mouse. Based on this, luminous intensity was checked. As a result, total particle number concentration of each port had average value of $3.17{\times}10^6{\sharp}/cm^3$ and range of the highest and lowest concentration value was approximately ${\pm}4.8%$. Autopsy of lung tissues of mouse showed that it had clearly better delivery of gene compared to the control group.

A NEWLY DEVELOPED CONTINUOUS TOXICITY TEST SYSTEM USING A LUMINOUSLY MODIFIED TERRESTRIAL BACTERIUM

  • Cho, Jang-Cheon;Lee, Kyu-Ho;Lee, Dong-Hun;Jahng, Deok-Jin;Park, Han-Oh;Kim, Sang-Jong
    • 한국미생물생명공학회:학술대회논문집
    • /
    • 한국미생물생명공학회 2000년도 Proceedings of 2000 KSAM International Symposium and Spring Meeting
    • /
    • pp.108-113
    • /
    • 2000
  • Freshwater borne bacteria transformed with luxAB-containing plasmid were optimized for the toxicity tests of various organic carbons and heavy metals. The EC$\sub$50/ values obtained from tests using the most sensitive bacterium to toxicants, YH9-RC, revealed to be much less than those from the Microtox$\^$/. In addition, some physiological characteristics of this bacterium under the toxic stress conditions such as potential bioluminescence, specific growth rate, and intracellular ATP contents, reproducibly and reliably correlated to the toxicity of the chemicals exposed. The higher concentrations of COD in wastewater samples, the lower EC$\sub$50/ values, therefore the developed toxicity test was found to be easily applicable to the toxicity test for wastewater samples and effluents. The conditions for constructing 384-multiwell plate containing freeze-dried bacterium were also optimized through the addition of 0.16 M trehalose before freeze-drying. Consequently, the advanced test system featuring a continuous measurement of the toxicity, an automated real-time monitoring of its results, and an alerting function was designed and constructed in combination with the microbiological, mechanical, and electronic compartment.

  • PDF

STATE-OF-THE-ART TECHNOLOGY USING GENETICALLY-ENGINEERED BIOLUMINESCENT BACTERIA AS ENVIRONMENTAL BIOSENSORS

  • Gu, Man-Bock
    • 한국미생물생명공학회:학술대회논문집
    • /
    • 한국미생물생명공학회 2000년도 Proceedings of 2000 KSAM International Symposium and Spring Meeting
    • /
    • pp.94-99
    • /
    • 2000
  • Bioluminescence is being used as a prevailing reporter of gene expression in microorganisms and mammalian cells. Bacterial bioluminescence draws special attention from environmental biotechnologists since it has many advantageous characteristics, such as no requirement of extra substractes, highly sensitive, and on-line measurability. Using bacterial bioluminescence as a reporter of toxicity has replaced the classical toxicity monitoring technology of using fish or daphnia with a cutting-edge technology. Fusion of bacterial stress promoters, which control the transcription of stress genes corresponding to heat-shock, DNA-, or oxidative-damaging stress, to the bacterial lux operon has resulted in the development of novel toxicity biosensors with a short measurement time, enhanced sensitivity, and ease and convenient usage. Therefore, these recombinant bioluminescent bacteria are expected to induce bacterial bioluminescence when the cells are exposed to stressful conditions, including toxic chemicals. We have used these recombinant bioluminescent bacteria in order to develop toxicity biosensors in a continuous, portable, or in-situ measurement from for air, water, and soil environments. All the data obtained from these toxicity biosensors for these environments were found to be repeatable and reproducible, and the minimum detection level of toxicity was found to be ppb (part per billion) levels for specific chemicals.

  • PDF

국내 유통되는 농약 유효성분에 대한 안전보건정보 데이터베이스 구축 (A Study on Developing Safety and Health Information Database of Pesticide Ingredients Used in Korea)

  • 임경채;최상준
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.27-35
    • /
    • 2010
  • In this study, we have developed the database of safety and health information for pesticide active ingredients used in Korea. There were 1,283 pesticide items among which 296 were found to be out of use in current. A total of 349 pesticide ingredients were being used in Korea. The database consists of 32 types of information including chemical characteristics, acute toxicity, chronic toxicity (carcinogenic and reproductive toxicity), specific symptoms by exposure route and first aid. When pesticide ingredients were assessed in terms of key properties such as color, odor, acute toxicity, carcinogenic and reproductive toxicity, they were white, colorless and odorless, in general. When ingredients were classified by category of acute toxicity, 'Non-hazardous' represented 29%, followed by 'Slightly hazardous' at 16%, 'Moderately hazardous' at 14%, 'Highly hazardous' at 5%, and 'Extremely hazardous' at 2%. 85 out of 349, or 24% of ingredients were found to be possibly carcinogenic to human. This database is expected to provide an easy access for farmers, agriculture supervisors, researchers and consumers, and it can ultimately be used as basic data on farmer's safety and health.

염 함유 폐수처리수에 대한 Daphnia magna 및 Vibrio fischeri 급성독성 비교연구 (Comparative Study on Acute Toxicity of Treated Effluent Containing Salt using Daphnia magna and Vibrio fischeri)

  • 김종민;신기식;유순주;이정서;김웅기
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.453-459
    • /
    • 2015
  • This paper aims to evaluate the results of acute toxicity testing with Daphnia mag$Na^+$ and Vibrio fischeri and characteristics of ionic substance of treated effluent which contained salt. Acute toxicity with Daphnia mag$Na^+$ and Vibrio fischeri and salinity of 19 samples (4 business categories) were a$Na^+$lysed. Salinity of effluent could explain the fluctuation of toxicity with D. mag$Na^+$ about 66% ~ 91% ($r^2=0.66{\sim}0.91$). The results of acute toxicity testing with V. fischeri of treated effluent (aggregate manufacture facilities) did not indicate toxicity (TU = 0), whereas that of chemical manufacture facilities indicated toxicity. V. fischeri, a candidate test organism, seemed suitable test organism for acute toxicity testing of effluent except high salinity (above 65‰ ~ 70‰) in aggregate manufacture facilities (nonmetalic minerals facilities). The performance of ion composition about treated effluent of surveyed facilities indicated that ion concentration of $Na^+$ (5,740 mg/L) and $Cl^-$ (9,727 mg/L) showed high level among 6 major ions ($Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $SO_4{^{2-}}$, $Cl^-$) in effluent of nonmetalic minerals facilities. In addition, Clion seemed to influence the D. magna survival rather than $Na^+$ ion.

담수 물벼룩 Daphnia magna의 자외선 B 적응이 자외선과 중금속의 동시노출에 따른 독성반응에 미치는 영향 (Effect of Ultraviolet-B Radiation Acclimation to Fresh Water Daphnia magna Simultaneously Exposed to Several Heavy Metals and UV-B Radiation)

  • 김정곤;이민정;오소린;최경호
    • 한국환경보건학회지
    • /
    • 제33권2호
    • /
    • pp.123-131
    • /
    • 2007
  • Many environmental contaminants including several metals, polycyclic aromatic hydrocarbons, and pharmaceuticals, have been identified to be phototoxic in the water environment. Concerns regarding photo-enhancement of toxicity of several environmental contaminants have been increasing because of the increased level of ultraviolet irradiation on the earth surface. However, there exist arguments that there might be certain defense mechanisms taking place in the aquatic ecosystem, which may include behavioral characteristics or genetic acclimation. This study was conducted to understand the potential responses of aquatic receptors to several phototoxic metals in the real environment, where long-term acclimation of such organisms to low dose UV-B may take place. For this purpose, water flea Daphnia magna was acclimated to environmentally relevant dose of UV-B (12 to $18uW/cm^2$) for >11 generations. The differences in developmental and life history characteristics, and toxicity responses were evaluated. Acclimation did not affect the daphnids' growth, longevity, and reproduction characteristics such as time to first brood, and brood size: After 21 d, survival of D. magna was not influenced by UV-B acclimation. When the number of young per female was compared. the daphnids acclimated for 11 generations tend to produce less number of neonates than the un-acclimated individuals but with no statistical significance (p>0.05). Four metals that were reported to be phototoxic elsewhere were employed in this evaluation, that include As, Cd. Cu, and Ni. UV-B level being applied in acclimation did increase the toxicity of Cd and Cu, significantly (p<0.05). However, the toxicities of As and Ni were not affected by irradiation of UV-B. Phototoxic responses were evaluated between the acclimated and the un-acclimated daphnids. For Cu, UV-B acclimation led to reduction of the photo-induced toxicity $(p\approx0.1)$ in daphnids. Non-acclimated Daphnia were affected by 50% at 4.18 ug/l Cu. but UV-B acclimated individuals exhibited $EC_{50}$ of 5.89 ug/l. With Cd, UV-B acclimation appeared to increase phototoxicity (p>0.05). With As and Ni, UV-B acclimation did not influence photo-induced toxicity. This observation may be in part explained by the type of reactive oxygen species that were generated by each metal. Similar to UV-B light, Cu is known to generate superoxide anion by acting as redox cycling toxicant. This is one of the first studies that employed_laboratory based UV-B acclimated test species for photoenhanced toxicity evaluation.

어류수정란 발달에 미치는 나노독성 연구동향: (1) 탄소계 및 기타 나노물질 (Effect of Nanomaterials on the Early Development of Fish Embryos: (1) Carbon and Other Nanomaterials)

  • 신유진;안윤주
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.762-767
    • /
    • 2012
  • The ecotoxicity assessment of nanomaterials (NMs) in the environment is actively conducted throughout the world because of the concerns about their potential risk from usage and release into the environment, as well as their unique physiochemical properties. Ecotoxicity tests for NMs have been conducted using various species and methods; however, in spite of these efforts, the characteristics and toxicity of NMs have not been defined. The fish embryo toxicity test (FET) has been conducted extensively to evaluate the toxicity of NMs as an alternative to a whole-body test in fish. In this study, we collected and analyzed the trends of nanotoxicity on the early development of freshwater fish. The model nanomaterials are carbon NMs ($C_{60},\;C_{70},\;C_{60}$(OH)n and carbon nanotube). Their adverse effects were extensively investigated based on the properties of NMs, test species, and diverse exposure conditions.

전자빔 공정을 적용한 Triclosan의 제거특성 및 독성평가 (Toxicity Assessment and Decomposition Characteristics of Triclosan in an E-beam Irradiation Process)

  • 장태범;장순웅;이시진;조일형
    • 한국지반환경공학회 논문집
    • /
    • 제13권3호
    • /
    • pp.5-11
    • /
    • 2012
  • 본 연구의 목표는 전자빔 공정을 적용하여 Triclosan의 제거효율 및 독성평가를 하는 것이다. 이 실험에서는 전자빔 선량과 Triclosan의 초기 농도에 따른 저감 효율 및 스캐벤저 가스에 따른 무기화의 정도를 알아보았다. 또한 녹조류 중 하나인 Pseudokirohneriella Subcapitata를 이용하여 생물독성과 위해성 평가를 통한 독성저감기술을 시험하였다. 그 결과 Triclosan은 전자빔 조사량이 증가할수록 분해 효율이 향상되었고, 라디칼 스캐벤저 가스에 의한 TOC 제거는 $N_2O$$O_2$를 용해시켰을 때 효율이 증가된 것으로 나타났다. 4일(96hrs) 후 독성평가 결과 전자빔 조사 강도의 증가에 따라 독성 영향이 저감되는 것을 알 수 있었다.

간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가 (Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.

Concise Clinical Review of Hematologic Toxicity of Linezolid in Multidrug-Resistant and Extensively Drug-Resistant Tuberculosis: Role of Mitochondria

  • Oehadian, Amaylia;Santoso, Prayudi;Menzies, Dick;Ruslami, Rovina
    • Tuberculosis and Respiratory Diseases
    • /
    • 제85권2호
    • /
    • pp.111-121
    • /
    • 2022
  • Multidrug-resistant tuberculosis (MDR-TB) is caused by an organism that is resistant to both rifampicin and isoniazid. Extensively drug-resistant TB, a rare type of MDR-TB, is caused by an organism that is resistant to quinolone and one of group A TB drugs (i.e., linezolid and bedaquiline). In 2018, the World Health Organization revised the groupings of TB medicines and reclassified linezolid as a group A drug for the treatment of MDR-TB. Linezolid is a synthetic antimicrobial agent in the oxazolidinone class. Although linezolid has a good efficacy, it can cause substantial adverse events, especially hematologic toxicity. In both TB infection and linezolid mechanism of action, mitochondrial dysfunction plays an important role. In this concise review, characteristics of linezolid as an anti-TB drug are summarized, including its efficacy, pathogenesis of hematologic toxicity highlighting mitochondrial dysfunction, and the monitoring and management of hematologic toxicity.