• 제목/요약/키워드: Characteristic testing system

검색결과 174건 처리시간 0.041초

대전력 시험전압 측정방법에 대한 고찰 (The study of test voltage measuring system for high-power testing laboratory)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 2005
  • This paper describes the optimal design, construction and performance evaluation of voltage divider used in high power testing laboratory for voltage measuring system. These dividers, which are of R, C, R&C type voltage dividers, the voltage to be measured range from voltage to several ten kilovolts, the frequency of the signals has a bandwidth from DC to megaHertz Measuring transient voltage and currents in the high voltage power laboratory is generally accompanied by electromagnetic interface and induced noise. above all, the measuring capabilities of voltage measuring system are dependent upon short response time and it must be as free as possible of inductive effects. In this paper presents both characteristic of voltage divider and design of voltage measuring system.

  • PDF

음향방출기법을 이용한 원전 고온 고압 배관의 누설 특성 평가에 관한 연구 (A Study on the Leakage Characteristic Evaluation of High Temperature and Pressure Pipeline at Nuclear Power Plants Using the Acoustic Emission Technique)

  • 김영훈;김진현;송봉민;이준현;조윤호
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.466-472
    • /
    • 2009
  • 고온, 고압의 원자력 배관 누설 판별을 위해 음향방출기법(AE)을 이용한 누설감지 시스템인 ALMS 기법이 적용되고 있다. 이 시스템은 단지 AE 센서로 전해진 신호의 RMS값을 이용하여 누설의 유무만을 판단할 뿐, 누설 발생시 누설부의 크기나 형태를 평가하는 것에는 어려움이 있었다. 따라서 본 논문에서는 이러한 문제를 해결하기 위하여 AE센서와 가속도센서를 동시에 이용한 이중 센서 시스템을 제안하였다. 빠른 학습 속도와 정확성을 위해 Levenberg-Marquardt 학습 알고리즘을 이용한 인공신경회로망을 적용시키고, 이를 통해 신뢰성 있는 분석 결과를 얻을 수 있다. 배관내 압력과 누설부의 크기와 모양에 따른 실험신호들을 학습시키고 그 판별 정확성을 확인하였다. 추가적으로 배관 두께에 따라 발생하는 파(wave)의 종류와 특성이 달라지는 것을 이론과 실험을 통하여 알아보았다.

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권5호
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

전력설비에 대한 내오손특성 평가설비 구축 (Construction of the evaluating facilities against contamination characteristic for power installation)

  • 이정기;김민규;정주영;김익수;문인욱;강영식;성문주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

음향방출 신호의 검출을 위한 공진형 및 광대역 센서 제작과 특성평가 (Development and Characterization of High-Performance Acoustic Emission Sensors)

  • 김병극;김영환
    • 비파괴검사학회지
    • /
    • 제12권4호
    • /
    • pp.9-17
    • /
    • 1993
  • Three types of piezoelectric sensors to detect acoustic emission signals were developed and characterized. Epicentral displacement and velocity of a plate to have infinite boundary were calculated by convolution between a Green's function and a simulated source time function to show parabolic rising characteristic. The sensor calibration system set up was composed of a steel plate, a glass capillary, an indentor and a load cell indicator The transient elastic signals were detected by the sensors. The results were compared with the theoretical results and Fast Fourier Transformed. As the results, the sensor fabricated using a disk shape of a piezoelectric PZT element showed resonant characteristics. The sensors fabricated using a conical shape PZT element and a PVDF polymer film showed the wide band characteristics for particle displacement and velocity, respectively. The calculated results showed good agreements with the transient responses in the cases of the wide band sensors and it was confirmed that the simulated source time function had been properly assumed.

  • PDF

FRF 누설오차 개선에 의한 전달함수 합성법의 향상 (An Enhancement of Transfer Function Synthesis by Improving the Leakage Error of FRF)

  • 안세진;정의봉;김승엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.517-522
    • /
    • 2002
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing is widely used to obtain the modal characteristics of structures. However, the FRF obtained from impact hammer testing contains several errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove these errors is proposed so as to enhance results of TFS. Numerical examples show that the FRF of full structure can be predicted exactly by the method proposed in this paper.

  • PDF

Infrared Thermography Quantitative Diagnosis in Vibration Mode of Rotational Mechanics

  • Seo, Jin-Ju;Choi, Nam-Ryoung;Kim, Won-Tae;Hong, Dong-Pyo
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.291-295
    • /
    • 2012
  • In the industrial field, real-time monitoring system like a fault early detection is very important. For this, the infrared thermography technique as a new diagnosis method is proposed. This study is focused on the damage detection and temperature characteristic analysis of ball bearing using the non-destructive infrared thermography method. In this paper, thermal image and temperature data were measured by a Cedip Silver 450 M infrared camera. Based on the results, the temperature characteristics under the conditions of normal, loss lubrication, damage, dynamic loading, and damage under loading were analyzed. It was confirmed that the infrared technique is very useful for the detection of the bearing damage.

계측기에서 얻어진 주파수 응답 함수의 오차 제거 방안 - 전달함수 합성법에의 응용 - (A Suggestion of Method to Remove Bias Error of the FRF Obtained by FFT Analyzer - Application of TFS -)

  • 김승엽;정의봉;서영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.408-413
    • /
    • 2003
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing Is widely used to obtain the modal characteristics of structures However. the FRF obtained from impact hammer testing contains bias errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove hose errors is proposed so as to enhance results of TFS. Numerical and experimental examples show that the FRF of full structure can be predicted nearly exactly by the method proposed in this paper.

  • PDF

신경계 이상을 동반하는 선천성 대사 질환 (Inherited Metabolic Disorders Involving the Nervous System)

  • 유지숙
    • 대한유전성대사질환학회지
    • /
    • 제23권2호
    • /
    • pp.21-30
    • /
    • 2023
  • Inherited metabolic disorders (IMD) are a group of disorders caused by defects in specific biochemical pathways. Up to 85% of IMD display predominantly neurological manifestations by affecting neurodevelopment or causing neurodegeneration. These neurometabolic disorders present with a variety of neurological and non-neurological manifestations. Early diagnosis of IMD is important because some disorders can be treated or improved with specific treatment if detected early. For prompt diagnosis and treatment, it is important to suspect IMD by being familiar with the clinical characteristics, biochemical abnormalities, and characteristic neuroimaging patterns that appear in IMD. Genetic testing, including next-generation sequencing, is also important in diagnosing IMD. During the follow-up of patients with IMD, it is necessary to conduct regular physical and neurological examinations in addition to disease-specific management.

  • PDF

고속선로변 2중화 정보처리모듈 시험방안 고찰 (A review of test method the Double-system Track side Functional Modules in High speed line)

  • 장석각;백승구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.603-609
    • /
    • 2008
  • 개발품의 품질을 평가하기 위해 무엇을 어떻게 시험할 것인가 적합한 모델을 정하는 것은 중요하다. 개발된 제품의 대부분의 패키지화된 소프트웨어는 소스코드를 공개하지 않으므로 외부적인 동작 특성을 측정하여 평가한다. 고속철도 선로변 정보처리 기기는 단일계로 구성되어 있던 것을 최근에 2중화하므로 신뢰성을 향상하도록 개발하였다. 철도에 사용되는 용품에 대하여 성능 및 안전성을 확보하기 위하여 철도안전법에서 공인시험기관에서 품질인증을 받을 수 있도록 하고 있어 우선 규정의 적용 가능성을 검토를 하였다. 아울러 정보처리모듈 일반 및 전용 그리고 절체기에 대하여 H/W 와 S/W의 검증을 위하여 필요한 절차와 성능을 확인하는 방안을 검토하고, TFM(Track-side Functional Module) Tester기와 Simulator를 활용하여 보드별 성능시험을 하는 방안에 대하여 고찰하고자 한다.

  • PDF