• Title/Summary/Keyword: Characteristic parameters

검색결과 2,075건 처리시간 1.079초

Dynamics of Technology Adoption in Markets Exhibiting Network Effects

  • Hur, Won-Chang
    • Asia pacific journal of information systems
    • /
    • 제20권1호
    • /
    • pp.127-140
    • /
    • 2010
  • The benefit that a consumer derives from the use of a good often depends on the number of other consumers purchasing the same goods or other compatible items. This property, which is known as network externality, is significant in many IT related industries. Over the past few decades, network externalities have been recognized in the context of physical networks such as the telephone and railroad industries. Today, as many products are provided as a form of system that consists of compatible components, the appreciation of network externality is becoming increasingly important. Network externalities have been extensively studied among economists who have been seeking to explain new phenomena resulting from rapid advancements in ICT (Information and Communication Technology). As a result of these efforts, a new body of theories for 'New Economy' has been proposed. The theoretical bottom-line argument of such theories is that technologies subject to network effects exhibit multiple equilibriums and will finally lock into a monopoly with one standard cornering the entire market. They emphasize that such "tippiness" is a typical characteristic in such networked markets, describing that multiple incompatible technologies rarely coexist and that the switch to a single, leading standard occurs suddenly. Moreover, it is argued that this standardization process is path dependent, and the ultimate outcome is unpredictable. With incomplete information about other actors' preferences, there can be excess inertia, as consumers only moderately favor the change, and hence are themselves insufficiently motivated to start the bandwagon rolling, but would get on it once it did start to roll. This startup problem can prevent the adoption of any standard at all, even if it is preferred by everyone. Conversely, excess momentum is another possible outcome, for example, if a sponsoring firm uses low prices during early periods of diffusion. The aim of this paper is to analyze the dynamics of the adoption process in markets exhibiting network effects by focusing on two factors; switching and agent heterogeneity. Switching is an important factor that should be considered in analyzing the adoption process. An agent's switching invokes switching by other adopters, which brings about a positive feedback process that can significantly complicate the adoption process. Agent heterogeneity also plays a important role in shaping the early development of the adoption process, which has a significant impact on the later development of the process. The effects of these two factors are analyzed by developing an agent-based simulation model. ABM is a computer-based simulation methodology that can offer many advantages over traditional analytical approaches. The model is designed such that agents have diverse preferences regarding technology and are allowed to switch their previous choice. The simulation results showed that the adoption processes in a market exhibiting networks effects are significantly affected by the distribution of agents and the occurrence of switching. In particular, it is found that both weak heterogeneity and strong network effects cause agents to start to switch early and this plays a role of expediting the emergence of 'lock-in.' When network effects are strong, agents are easily affected by changes in early market shares. This causes agents to switch earlier and in turn speeds up the market's tipping. The same effect is found in the case of highly homogeneous agents. When agents are highly homogeneous, the market starts to tip toward one technology rapidly, and its choice is not always consistent with the populations' initial inclination. Increased volatility and faster lock-in increase the possibility that the market will reach an unexpected outcome. The primary contribution of this study is the elucidation of the role of parameters characterizing the market in the development of the lock-in process, and identification of conditions where such unexpected outcomes happen.

남해 광양만에서 오염원에 따른 화학적 산소요구량과 대장균의 해역별 분포특성 (Distribution characteristics of chemical oxygen demand and Escherichia coli based on pollutant sources at Gwangyang Bay of South Sea in Korea)

  • 백승호
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3279-3285
    • /
    • 2014
  • 광양만에서 화학적 산소요구량, 엽록소-${\alpha}$ 및 분변계 대장균의 계절적, 지역적 분포특성을 파악하기 위해, 2010년 2월부터 2012년 11월까지 계절 조사를 수행하였다. 아울러 광양만의 오염정도와 해역의 지리학적 특성을 바탕으로 20개 정점을 3개의 구역(I, II, III)을 나누어 평가하였다. 조사기간 중 수온과 염분은 각각 $4.68-28.63^{\circ}C$와 1.94-33.84 psu의 범위에서, 엽록소-${\alpha}$는 0.31-35.10 ${\mu}gL^{-1}$과 화학적 산소요구량은 0.70-13.35 $mgL^{-1}$범위에서 변이를 보였다. 총 엽록소-${\alpha}$ 농도는 2010년 하계에 광양만 내측의 구역I에서 높은 농도로 관찰되었고, 만 외측의 구역 III으로 갈수록 감소하였다. COD는 지역별로는 2010년 동계, 춘계, 하계에 내만에서 높게 나타났고, 특히 춘계에는 섬진강의 영향을 강하게 받는 지역 II에서 높은 값을 보여 수질이 나쁘게 나타났다. 대장균 E. coli는 2011년 하계 정점1(지역I)에서 3550 $cfuL^{-1}$로 최고치를 기록하였고, 외측의 지역 III에서 상대적으로 낮았다. 춘계와 하계의 수온 증가(r=0.31 p<0.05)와 더불어 염분감소(r=-0.55 p<0.05)는 대장균 증식에 중요한 촉진제 역할을 한 것으로 파악되었다. 결과적으로 광양만 내만은 춘계와 하계 집중강우로 인한 육상기원의 담수의 유입으로 높은 영양염과 함께 분변계 대장균이 지역I과 지역II에서 현저하게 영향을 미쳐 오염화 현상이 두드려졌다.

지질학적 활용을 위한 Landsat TM 자료의 자동화된 선구조 추출 알고리즘의 개발 (A Development of Automatic Lineament Extraction Algorithm from Landsat TM images for Geological Applications)

  • 원중선;김상완;민경덕;이영훈
    • 대한원격탐사학회지
    • /
    • 제14권2호
    • /
    • pp.175-195
    • /
    • 1998
  • 위성영상으로부터 자동화된 선구조 추출 알고리즘은 지형적 특징에 따라 다양한 방법으로 개발되어 왔다. 국내 지형은 주로 산악지형에 가깝지만 충적층 지대가 함께 발달되어 있으며 이와 같은 충적층은 종종 단층과 같은 주요 선구조를 이루고 있다. 그러나 기존의 방법들은 이와 같은 복합적인 지형에 대해 적용하는데 여러 가지 문제점들이 있다 이에 따라 본 연구에서는 이러한 지형적 특징을 나타내는 지역에 적용 가능한 새로운 알고리즘을 개발하였다. 위성영상으로부터 선구조 요소와 비 선구조 요소로 구분되는 이진영상을 생성하기 위해 DSTA(Dynamic Segment Tracing Algorithm)를 개발하였다. DSTA는 선구조 추출시 발생하는 태양방위각에 따른 선택적 증감효과를 제거하고 동적 소창문(dynamic sub window)의 사용에 의해 명암차가 낮은 지역에서의 잡음(noise)을 상당히 제거하였다. 또한, 충적층 처리 루틴은 충적층 지역에서 나타나는 잡음 대부분을 제거하여 효과적으로 선구조를 추출할 수 있었다. 이진영상으로부터 선구조의 양끝점을 결정하기 위해 일반 영상자료 처리에 이용되고 있는 Hierarchical Hough 변환 또는 Generalized Hough 변환을 지질학적 적용에 적합하도록 결합연산 과정을 결합한 ALEHHT(Automatic Lineament Extraction by Hierarchical Hough Transform) 및 ALEGHT (Automatic Lineament Extraction by Generalized Hough Transform) 알고리즘을 개발하였으며, 이를 이용하여 지질학적으로 이용 가능한 선구조를 구하였다. 본 연구에서 제안된 결합연산 과정은 두선 사이의 사이각($\delta$$\beta$), 수직거리(d$_{ij}$) 및 중점거리(dn)를 이용하였다. 개발된 알고리즘을 Landsat TM 자료에 적용하여 지질학적 선구조를 추출한 결과, 산악지역 및 충적층 지대에 발달한 선구조 모두 잘 추출되었으며 태양방위각에 평행한 서북서방향의 선구조 역시 잘 드러나고 있어 만족할 만한 결과를 얻을 수 있었다. 그러나 효과적으로 알고리즘을 사용하기 위해서는 적절한 입력변수의 사용이 필수적이며, 특히 ALEGHT의 입력변수 중 영상 정량화 간격(drop)에 의한 영향은 차후의 연구에서 수행, 보완되어야 할 것으로 사료된다.

MODIS와 TOMS자료를 이용한 2001년 동북아시아 지역의 대기 에어로졸 모니터링 (Atmospheric Aerosol Monitoring Over Northeast Asia During 2001 from MODIS and TOMS data)

  • 이권호;홍천상;김영준
    • 대한원격탐사학회지
    • /
    • 제20권2호
    • /
    • pp.77-89
    • /
    • 2004
  • 동북아시아 지역의 에어로졸 광학두께의 시공간적 변화는 기후변화에 큰 역할을 하는 대기중의 에어로졸의 연구에 있어 매우 중요하다. 본 연구에서는 MODIS를 이용한 에어로졸 광학두께 자료와 TOMS 에어로졸 인덱스 자료를 수집하여 2001년 한해동안의 에어로졸의 물리학적 광학적 특성을 살펴보았다. 일별 에어로졸 관측 자료를 분석한 결과 에어로졸의 계절별 변화양상은 봄에 높고 겨울에 낮음을 뚜렷이 나타내고 있었다. 한편, 지역별 특징은 2001년에 MODIS에 의해 관측된 에어로졸 광학 두께의 연평균 값은 베이징이 가장 높은 0.65$\pm$0.37이고 고산이 가장 낮은 0.31$\pm$0.19로 나타났으며 서울과 광주가 각각 0.54$\pm$0.26과 0.38$\pm$0.19로 관측되었다. 이러한 연중 에어로졸 분석결과를 바탕으로 2001년 봄철 ACE-Asia 집중 관측 기간 중에 MODIS 와 TOMS 관측 자료를 이용한 한반도 인근지역의 에어로졸 특성을 조사하였다. 봄철에 높은 값을 보이는 에어로졸 광학두께(>0.7)와 에어로졸 인덱스 값(>0.5), 그리고 낮은 값을 나타내는 ${\AA}$ngstrom 지수 (<0.5)는 모두 봄철 황사현상에 의한 것이다. 그러나 때때로 황사와 같이 큰 입자가 아닌 다른 오염원에 의한 에어로졸로 인한 영향도 발견되고 있어 중국에서 발생한 오염된 에어로졸이 한반도로 이동하는 것이 원인으로 사료된다. 위성영상에서 나타난 에어로졸의 공간적 분포양상이 이를 입증하고 있다. 따라서 동북아시아 지역의 에어로졸 특성을 나타내는데 위성자료의 활용도는 매우 효과적이다. 않았다. 2) 체내에 축적된 질소율(외관상의 생물가)은 상ㆍ하번초형 혼과초지가 54.5%으로 상번초형 혼파초지의 53.7%보다 높았으나 유의적인 차이는 인정되지 않았다. 3) 외관상 대사에너지의 축적률은 상ㆍ하번 초형 혼파초지가 59.4%으로 상번초형 혼파초지의 58.2%보다 약간 높은 편이었으나 유의적인 차이는 인정되지 않았다. 따라서, 산양에 의한 목초의 이용성은 두 혼파 초지간에 큰 차이가 없는 것으로 나타나, 혼파초지내 turf type 초류도 사초자원으로써 이용가치가 있다고 하겠다.ue 및 orchardgrass 등의 식생비율이 높았으며, redtop, red fescue와 같은 하번초 초종의 식생도 비교적 고르게 유지되었다. 따라서, 상번초형 혼파초지에 비하여 상ㆍ하번초형 혼파초지는 목초의 건물수량과 품질에는 큰 영향을 미치지 못하였으나, 건물소화율 및 가소화건물수량이 높았고(p < 0.05), 연중 고르게 식생을 유지할 수 있었던 것으로 보아 생장습성이 다른 초종을 다양하게 혼파 이용하는 것도 좋을 것으로 사료된다.4.3 : 73.3으로 단백질과 지방이 약간 부족하다고 볼 수 있다. 4) 법무부 급식관리위원회의 수용자 급식기준과 각 형무소의 보통활동 수형자를 위해 공급하는 영양량을 종합적으로 비교해보면 총열량 공급량은 조선 경성형무소(Kim CH 2003)에서는 3966.5 ㎉로 급식기준열량의 159.9%로 공급량이 높았으며, 대만 신죽 형무소에서는 소년 수형자임에도 89.6%만을 공급하고 있었다. 프랑스와 독일은 각각 110.9%, 107.1%로 급식기준을 조금 넘는 적정열량에서 가까운 양을 공급하였다고 할 수 있다. 일제하의 조선, 세계공황 이후 식량이 극도로 부족한 상황에서 대만,

불화수소 누출사고 사례를 통한 주변 농작물의 환경피해 (Environmental Damage to Nearby Crops by Hydrogen Fluoride Accident)

  • 김재영;이은별;이명지
    • 한국환경농학회지
    • /
    • 제38권1호
    • /
    • pp.54-60
    • /
    • 2019
  • 본 연구는 실제 불화수소 누출 사고에 대한 OCA(Off-site consequence analysis) 분석을 통해 최악 및 대안의 사고시나리오를 선정하여 사고영향범위 예측치를 평가하고, 사고 반경 내 농작물의 잔류오염도를 측정함으로써 화학사고로부터 발생될 수 있는 환경 피해영향범위를 도출하고자 하였다. KORA 소프트웨어를 이용하여 사고영향범위를 분석한 결과, 최악의 사고시나리오는 사고 발생지점으로부터 10 km 이상, 대안의 사고시나리오는 1,968 m의 영향범위가 산정되었고, ALOHA 소프트웨어 구동 결과는 약 1.9 km를 나타내었다. 아울러, 실제 사고 지역 내 농작물의 불소화물 잔류 여부를 측정한 결과, 피해지역 내 불소화물 농도는 4.96~276.82 mg/kg 범위로 사고 발생지점 인근이(E-1) 가장 높았고(276.82 mg/kg), 동쪽방향으로 멀어질수록 잔류농도가 감소하는 경향이었다. 한편, 북동 방향 2지점과 남동 방향 4지점은 사고 발생지점 인근보다는 낮은 경향이었다(4.96~28.98 mg/kg). 이러한 결과를 비추어 2 km 내외 지점의 불소화물 농도가 5 mg/kg 이하의 미미한 수준과 대안의 사고시나리오 예측 영향범위인 약 1.9 km를 고려했을 때 피해영향범위는 약 2 km 내외 수준인 것으로 추정된다. 이와 같이 OCA 평가는 누출조건, 기상조건, 시간경과에 따른 물리화학적 변수 등을 사고현장과 동일하게 입력할 수 없기 때문에 실제 피해영향범위와 다른 경향은 있지만 농작물 중 불소화물 잔류오염 여부를 동시에 평가함에 따라 화학사고로부터 화학물질의 확산범위를 산정하는데 있어 도움이 될 수 있을 것으로 판단된다.

산란계와 과산계의 난생산성, 계란품질, 혈액 특성 및 산란 전 행동 특성의 비교 (Comparison of Egg Productivity, Egg Quality, Blood Parameters and Pre-Laying Behavioral Characteristics of Laying Hens and Poor Laying Hens)

  • 이우도;김현수;손지선;홍의철;김희진;강환구
    • 한국가금학회지
    • /
    • 제49권4호
    • /
    • pp.189-197
    • /
    • 2022
  • 본 연구는 산란 능력에 따른 산란계의난생산성, 계란품질, 혈액특성 및 산란 전 특정 행동의빈도수와유지시간에대해 조사하였다. 45주령 Hy-line brown 산란계를2개처리구, 3반복으로 반복 당 2수씩 총 12수배치하였다. 처리구는 산란율이 80% 이상인 산란계(High egg production layers; HEP)와 산란율이 50% 이하인 과산계 및 비산란계(Poor egg performance layers; PEP)이며, 4주간 시험을 수행하였다. 산란율과 난중 및 계란품질은 매일 측정하였으며, 사료섭취량, 사료요구율은 사료 급이량과 사료 잔량을 고려하여 매주 측정하였다. 혈청 생화학 분석은 실험 종료일에 12시간 간격으로 2회 채혈하여 분석하였으며, 산란 전 행동 관찰은 전시험기간동안 점등 시간(06:00)부터 15:00까지 산란계의 행동을 녹화하여 앉기 행동 빈도수와 유지시간을 관찰하였다. 본 연구의 결과, HEP은 높은 산란율과 산란량 및 낮은 사료 요구율을 보였으나(P<0.05), 난중은 PEP에서 유의적인 차이를 보였다(P<0.05). 사료섭취량은 두 처리구에서 비슷한 결과를 나타내었다. 계란 품질에서 Haugh units와 난백고는 차이를 보이지 않았으나, PEP에서 어두운 난각색과 두껍고 단단한 난각을 형성하였으며 더 많은 양의 난각을 생산하였다 (P<0.05). 오전에 채혈한 혈청에서는 HEP에서 높은 TG를 보였으며, PEP는 ALT 수치가 높게 나타났다(P<0.05). 오후에 채혈한 혈청에서는 HEP에서 LDH 수치가 높았으며 (P<0.05), 그 외 혈청 생화학 성분은 처리구간 유의적인 차이를 보이지 않았다. 또한 시간대별 채취한 혈청 내 칼슘과 인의 비율은 두 처리구간 비슷하였다. 산란 1시간 전 HEP의 앉기 행동을 관찰한 결과 약 4회, 25분간 행동을 유지하는 것으로 조사되었으며 매주 비슷한 행동 빈도와 유지시간이 관찰되었다. 결론적으로 HEP와 PEP는 난생산성과 사료효율 및 계란품질에도 차이가 나타났으며, HEP는 산란 전에 앉기 행동이 빈번하게 관찰되고 오래 유지하였다. 하지만 특정 행동 관찰 외 계군 내 과산계와 비산란계를 판별할 수 있는 다양한 접근 방법 탐색 과 농가 적용 가능성에 대한 추가 연구가 필요할 것으로 사료된다.

삼축압축 하에서 지중연속벽 주변 방콕 연약 점토의 거동 (Behaviors of Soft Bangkok Clay behind Diaphragm Wall Under Unloading Compression Triaxial Test)

  • Le, Nghia Trong;Teparaksa, Wanchai;Mitachi, Toshiyuki;Kawaguchi, Takayuki
    • 한국지반공학회논문집
    • /
    • 제23권9호
    • /
    • pp.5-16
    • /
    • 2007
  • 비배수 상태에서의 변수 $S_u,\;E_u$, n의 함수로 표현되는 단순한 선형 완전점탄성 모델은 굴착 중에 연성 토양에 시공되는 지중연속벽의 변위를 예측하는데 사용된다. 그러나 유한요소해석에서의 이러한 모델은 굴착이 잠시 중단되었거나 완료된 후 지중연속벽의 측방향 변위를 연속적으로 예측하는 데 한계가 있다. 굴착이 이루어지지 않는 동안의 지중연속벽 주변 토양의 변형 거동특성을 연구하기 위하여, 지중연속벽 주변 토양에 작용하는 응력상태를 가정한 '방콕 연약 점토'에 대한 일련의 삼축압축시험이 모사되었다. 본 연구에서는 세 가지 다른 조건에서의 삼축압축시험이 실시되었는바, 압밀 비배수 조건에서의 재하($CK_0UC$), 압밀 배수 및 비배수 조건에서의 재하 및 제하($CK_0DUC$$CK_0UUC$)의 조건에서 시험이 실시되었다. 시험으로부터 일련의 $CK_0DUC$ 시험에서 얻은 전단강도는 $CK_0UC$ 시험에서의 잔류강도와 같음을 알 수 있었다. $CK_0DUC$ 시험에서 시험편에 가해지는 수평압력을 점진적으로 감소시키면서 측정한 탄성계수는 편차응력의 증가와 더불어 감소함을 알 수 있었다. 또한 $CK_0UC$$CK_0DUC$시험에서 한계상태 관계의 기울기가 동일하게 나타났다. 더욱이, $CK_0DUC$시험에서 수평압력을 점진적으로 감소시킬 경우의, 축방향 및 반경방향 변형율 증가율을 시간, 한계상태 관계의 기울기, 편차응력과 평균 유호응력의 비의 함수로 표현할 수 있었다. 이 연구는 삼축압축시험의 제하 과정에서 얻은 시험 결과가 굴착 중 지중연속벽의 변형을 예측하는데 사용될 수 있음을 보였다.AFM)과 Scanning Electron Microscopy(SEM)을 통해 관찰한 GST 다층박막시료의 고온 열처리 전후 표면미시거칠기 변화도 PRAM 기록기를 사용할 때에는 in-situ 타원계를 사용할 때보다 1/10 정도의 크기를 보여주어 PRAM 기록기와 분광타원계를 사용하여 결정한 GST의 고온광학물성의 신뢰성을 확인하여 주었다.>, 여자 $179.1{\pm}37.2%$이었다. 평균필요량에 비해 가장 낮은 양을 섭취한 영양소는 엽산으로서 남자 $60.1{\pm}10.8%$, 여자 $54.6{\pm}9.9%$로 조사되었다. 칼슘의 섭취량은 평균필요량에 비해 전체 $74.9{\pm}31.9%$로 나타났다. 에너지 섭취량에 있어서 남자 노인들은 모두가 필요추정량의 75% 미만을 섭취하고 있었고 여자 노인의 경우에도 97%가 필요추정량의 75% 미만을 섭취하여 에너지 섭취량이 매우 낮았다 반면에 단백질 섭취량에 있어서는 남자 노인의 경우 100%가 평균필요량의 125%를 초과하였고, 여자 노인의 경우에는 91%가 평균필요량의 125%를 초과하여 대조적이었다. 비타민 A와 E는 각각 평균필요량과 충분섭취량의 125%를 초과하는 비율이 높게 나타난 반면에 비타민 $B_2$는 특히 남자 노인에서 평균필요량의 75%미만을 섭취한 비율이 높게 나타났다. 엽산 섭취량에 있어서는 평균필요량의 75% 미만을 섭취한 비율이 전체 96%로 나타나 심각한 부족상태로 조사되었다 반면에 철의 섭취량은 남녀 모두 100%가 평균필요량의 125%를 초과하여 섭취한 것으로 나타났다. 아연의 섭취량은 남자 17%,여자 15%가 평균필요량의 75% 미만을 섭취한 것으로 조사되었다. 에너지와 엽산은 모든 노인들에서 평균필요량에 미달되게 섭취한

The Infrared Medium-deep Survey. VIII. Quasar Luminosity Function at z ~ 5

  • Kim, Yongjung;Im, Myungshin;Jeon, Yiseul;Kim, Minjin;Pak, Soojong;Hyun, Minhee;Taak, Yoon Chan;Shin, Suhyun;Lim, Gu;Paek, Gregory S.H.;Paek, Insu;Jiang, Linhua;Choi, Changsu;Hong, Jueun;Ji, Tae-Geun;Jun, Hyunsung D.;Karouzos, Marios;Kim, Dohyeong;Kim, Duho;Kim, Jae-Woo;Kim, Ji Hoon;Lee, Hye-In;Lee, Seong-Kook;Park, Won-Kee;Yoon, Yongmin;Byeon, Seoyeon;Hwang, Sungyong;Kim, Joonho;Kim, Sophia;Park, Woojin
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.34.3-34.3
    • /
    • 2020
  • Faint z ~ 5 quasars with M1450 ~ -23 mag are known to be the potentially important contributors to the ultraviolet ionizing background in the post-reionization era. However, their number density has not been well determined, making it difficult to assess their role in the early ionization of the intergalactic medium (IGM). In this work, we present the updated results of our z ~ 5 quasar survey using the Infrared Medium-deep Survey (IMS), a near-infrared imaging survey covering an area of 85 square degrees. From our spectroscopic observations with the Gemini Multi-Object Spectrograph (GMOS) on the Gemini-South 8 m Telescope, we discovered eight new quasars at z ~ 5 with -26.1 ≤ M1450 ≤ -23.3. Combining our IMS faint quasars with the brighter Sloan Digital Sky Survey (SDSS) quasars, we derive, for the first time, the z ~ 5 quasar luminosity function (QLF) without any fixed parameters down to the magnitude limit of M1450 = -23 mag. We find that the faint-end slope of the QLF is very flat (-1.2) with a characteristic luminosity of -25.7 mag. The number density of z ~ 5 quasars from the QLF gives lower ionizing emissivity and ionizing photon density than those in previous works. These results imply that quasars are responsible for only 10-20% of the photons required to completely ionize the IGM at z ~ 5, disfavoring the idea that quasars alone could have ionized the IGM at z ~ 5.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF