• 제목/요약/키워드: Characteristic impedance

검색결과 608건 처리시간 0.024초

축전 용량이 고려된 평판형 유도 결합 플라즈마 원의 등가회로 모델 (An equivalent Circuit Model of Transformer Coupled Plasma Source)

  • 김정미;권득철;윤남식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1760-1762
    • /
    • 2002
  • In this work we develop an equivalent circuit model of TCP(transformer coupled plasma) source and investigate matching characteristic. The developed circuit model includes transmission line, standard-type impedance matching network and displacement current in the plasma source. The impedance of TCP is calculated by previously developed program for various source parameters and dependance of components of matching impedance on the value of source impedance is investigated.

  • PDF

Branch-Line 구조를 이용한 높은 방향성을 가지는 결합기 설계 및 제작 (Design and Implementation of a directional coupler with high directivity using Branch Line Structure)

  • 심부석;이승철;한대현;안점영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.350-353
    • /
    • 2003
  • In this paper, we designed and implemented a 10dB directional coupler with high directivity using branch line structure. The characteristic impedance of parallel branch line for 10 dB directional coupler is about 150 $\Omega$. To realize high characteristic impedance in microstrip line, we used the coupled line structure. The directional coupler were implemental and measured. The measured results show that the directivity is high than 24 dB.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

전력선 통신을 위한 저압 배전 시스템의 임피던스 연구 (Study on Characteristic Impedance in LV Distribution System for PLC)

  • 김용성;김재철;이양진;조성민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2006
  • In this paper, the investigation of characteristic impedance on low voltage distribution system is described The residential area of LV distribution systems is researched for the modeling. At frequency range from 1MHz to 30Mhz, the input characteristic impedances of low-voltage distribution network are obtained with experiments. The low-voltage distribution system based on the model is built at the laboratory building. S parameters are measured by performing experiments. Finally, the characteristic impedances are reported.

  • PDF

전력선 통신 시스템의 입력 임피던스 계산 (Input Impedance Calculation of the Power Line Communication System)

  • 천동완;이진택;박영진;김관호;신철재
    • 한국통신학회논문지
    • /
    • 제29권9A호
    • /
    • pp.983-990
    • /
    • 2004
  • 본 논문에서는 중 전압 전력선을 이용한 전력선 통신대 LC) 네트워크의 입력임피던스를 계산하였다. 먼저 전송 선로 모델을 이용하여 전력선 통신 네트워크의 입출력 단 모델을 제시하였으며, 여기에 전력선의 방사성 손실, 도체손실, 유전체 손실 등에 의한 감쇠상수를 적용시켜 임피던스를 계산하였다 계산결과 방사성 손실에 의한 강쇠 가 가장 크게 나타났으며, 전력선의 특정임피던스가 매우커서 입력 단에서의 반사가 심하기 때문에 입력임피던스 가 일정한 주기를 가지는 정재파 형태로 나타남을 알 수 있었다 또한 입력임피던스의 주기는 동축선로의 길이에 주로 의존하고, 크기는 주로 전력선의 특성임피던스 및 손실에 의존하였다 실제 측정결과 계산 치와 측정치가 매 우 유사함을 알 수 있었다.

Impedance Matching Characteristic Research Utilizing L-type Matching Network

  • Jun Gyu Ha;Bo Keun Kim;Dae Sik Junn
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.64-71
    • /
    • 2023
  • If an impedance mismatch occurs between the source and load in a Radio Frequency transmission system, reflected power is generated. This results in incomplete power transmission and the generation of Reflected Power, which returns to the Radio Frequency generator. To minimize this Reflected Power, Impedance matching is performed. Fast and efficient Impedance matching, along with converging reflected power towards zero, is advantageous for achieving desired plasma characteristics in semiconductor processes. This paper explores Impedance matching by adjusting the Vacuum Variable Capacitor of an L-type Matching Module based on the trends observed in the voltage of the Phase Sensor and Electromotive Force voltage. After assessing the impedance matching characteristics, the findings are described.

  • PDF

광대역 동축선로 임피던스 변환회로의 동작 특성 분석 (The analysis of the operating characteristic for the wideband coaxial line impedance transformer)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.165-172
    • /
    • 2019
  • 두 개 이상의 동축선을 사용하여 한 쪽은 동축선을 직렬로 연결하고, 반대 쪽은 동축선을 병렬로 연결하면 광대역에서 동작하는 임피던스 변환회로가 된다. 동축선을 이용한 광대역 임피던스 변환회로는 동축선의 외곽 도체를 임피던스 변환에 이용하기 때문에 수식 또는 시뮬레이션 프로그램을 통한 예측이 매우 어렵다. 본 논문에서는 ${\lambda}/4$-마이크로스트립 선로 임피던스 변환회로의 선로 신호 감쇄에 대한 전달 특성(S21) 해석을 바탕으로 $25{\Omega}$ 동축선 두 개를 이용한 광대역 4:1($50{\Omega}:12.5{\Omega}$) 전송선로 임피던스 변환회로를 제작하여 동작 특성을 살펴보았다. 두 개의 동축선을 이용한 광대역 임피던스 변환기는 동축선의 길이를 90도(${\lambda}/4$)로 인식하는 주파수에서 신호 전달 특성(S21)이 급격히 감소하는 노치 특성이 발생하였다. 또한, 동축선 길이의 $0.06{\sim}0.2{\lambda}$에 해당하는 주파수 범위에서 신호 전달특성(S21) -0.2dB 이내의 값을 가졌다. 이러한 신호 전달특성(S21)은 출력 단에 연결된 마이크로스트립 선로의 길이 변화를 통해 약간의 동작 주파수 범위 변화와 원하는 주파수에서 최적의 신호 전달특성(S21)을 설정할 수 있음을 확인하였다.

Three Dimensional Finite Element Analysis for Piezoelectric Transformer

  • Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.98-103
    • /
    • 2001
  • This paper presents the numerical analysis of piezoelectric devices using three-dimensional finite element analysis. The characteristic of piezoelectric transducer, such as mechanical displacement and electrical are analyzed and the validity is confirmed by experiments Applying the finite element routine to a piezoelectric transformer, the resonance features electrical impedance. the ratio of step-up voltage and vibration mode of piezoelectric transformer are calculated numerically By using three-dimensional finite element method effects of width variation to resonance features, electrical input impedance and the voltage step-up ratio for a piezoelectric transformer, can be considered in design procedure.

Impedance characteristic of human arm for cooperative robot

  • Rahman, Mozasser;Ikeura, Ryojun;Mizutani, Kazuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.85.3-85
    • /
    • 2002
  • In this study, we tried to investigate the impedance characteristic of human arm in a cooperative task. Human arm was moved in a desired trajectory. The motion was actuated by a 1 degree-of-freedom robot system. As the muscle is mechanically analogous to a spring-damper system, a second-order equation was considered as the model for arm dynamics. In the model, inertia, stiffness and damping factor were considered. The impedance parameter was estimated from the position and torque data obtained from the experiment and based on the "Estimation of Parametric Model". It was found that the inertia is almost constant over the operational time. The damping factor and stiffness were high...

  • PDF

두꺼운 외부도체를 가진 손실이 있는 동축선로의 특성임피던스 근사 (Approximation of the Characteristics Impedance of a Lossy Coaxial Line with a Thick Outer Conductor)

  • 강진섭;김정환
    • 한국전자파학회논문지
    • /
    • 제11권4호
    • /
    • pp.649-656
    • /
    • 2000
  • 본 논문에서는 두꺼운 외부도체를 가진 손실이 있는 동축선로의 해석적인 특성임피선스 표현식 및 근사식을 제안했다. 그리고 제안된 근사식을 동축선로의 동작 주파수대역에서 사용 가능하다는 것을 3.5mm reference air line에 대해 보였다.

  • PDF