A study on the Dynamic Signature Verification System

  • Kim, Jin-Whan;Cho, Hyuk-Gyu;Cha, Eui-Young
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권3호
    • /
    • pp.271-276
    • /
    • 2004
  • This paper is a research on the dynamic signature verification of error rate which are false rejection rate and false acceptance rate, the size of signature verification engine, the size of the characteristic vectors of a signature, the ability to distinguish similar signatures, the processing speed and so on. Also, we present our efficient user interface and performance results.

유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가 (Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors)

  • 목성윤;강영록;김효진;계용욱;안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

인쇄체 문자 인식기의 성능 평가에 관한 연구 (A Study on Implementation of Printed Character Recognition System And Performance Evaluation)

  • 김민수;강은영;김우성;한선화;김진형
    • 한국정보처리학회논문지
    • /
    • 제7권11호
    • /
    • pp.3584-3591
    • /
    • 2000
  • 본 논문에서는 국내의 대표적인 상용인식기들의 성능을 평가하기 위한 평가 방법과 평가 기준을 제안한다. 제안한 평가 기준으로 상용화된 오프라인 문자인식기들과 실험실 인식기를 비교해본 후 각각의 특성을 분석해 보았다. 인식에 필요한 대상 문서는 400 DPI로 스캔한 1000여개의 문서영상과 수작업으로 작성한 원문이 존재하는 KT 테스트 컬렉션을 사용하였다. 본 논문에서 인식기의 성능을 평가하기 위해 문자단위 인식률 측정 방법을 제안하였다. 비교를 위한 문서의 유형을 제안하여, 단일 특성을 가지는 문서, 복합 특성을 가지는 문서 등으로 비교·분석하였다.