• Title/Summary/Keyword: Changing factor

Search Result 1,160, Processing Time 0.029 seconds

Preparation and Characterization of Nanoscaled Poly(vinyl alcohol) fibers via Electrospinning

  • Ding, Bin;Kim, Hak-Yong;Lee, Se-Chul;Lee, Douk-Rae;Choi, Kyung-Ju
    • Fibers and Polymers
    • /
    • v.3 no.2
    • /
    • pp.73-79
    • /
    • 2002
  • Nanoscaled PVA fibers were prepared by electrospinning. This paper described the electrospinning process, the processing conditions fiber morphology, and some potential applications of the PVA nato-fibers. PVA fibers with various diameters (50-250 nm) were obtained by changing solution concentration, voltage and tip to collector distance (TCD). The major factor was the concentration of PVA solution which affected the fiber diameter evidently. Increasing the concentration, the fiber diameter was increased, and the amount of beads was reduced even to 0%. The fibers were found be efficiently crosslinked by glyoxal during the curing process. Phosphoric acid was used as a catalyst activator to reduce strength losses during crosslinking. Scanning electron micrograph (SEM) and differential scanning calorimetric (DSC) techniques were employed to characterize the morphology and crosslinking of PVA fibers. It was fecund that the primary factor which affected the crosslinking density was the content of chemical crosslinking agent.

An Efficient Decoding Algorithm of LDPC codes (LDPC 부호의 효율적인 복호 방법에 관한 연구)

  • Kim, Joon-Sung;Shin, Min-Ho;Song, Hong-Yeop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1227-1234
    • /
    • 2004
  • In this paper, we propose a modified Normalized-BP algorithm by changing the normalization factor according to the reliability of updated messages. Proposed algorithm has almost same decoding complexity as Normalized-BP algorithm and achieves a bit-error probability of $10^4$within 0.02dB away from compared with LLR-BP algorithm.

A Model Predictive Controller for The Water Level of Nuclear Steam Generators

  • Na, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.102-110
    • /
    • 2001
  • In this work, the model predictive control method was applied to a linear model and a nonlinear model of steam generators. The parameters of a linear model for steam generators are very different according to the power levels. The model predictive controller was designed for the linear steam generator model at a fixed power level. The proposed controller at the fixed power level showed good performance for any other power levels by designed changing only the input-weighting factor. As the input-weighting factor usually increases, its relative stability does so. The steam generator has some nonlinear characteristics. Therefore, the proposed algorithm has been implemented for a nonlinear model of the nuclear steam generator to verify its real performance and also, showed good performance.

  • PDF

Critical Factors for Container Terminal Productivity

  • Park, Nam-Kyu;Kim, Joo-Young
    • Journal of Navigation and Port Research
    • /
    • v.33 no.2
    • /
    • pp.153-159
    • /
    • 2009
  • The awareness of the high-value industry for container terminal leads competitiveness of container terminals to keep high fiercely. In regards to competitive factors of container terminal, the most important point among several factors is seemed to be the speed of container loading and unloading on quayside. In container terminals in Korea, the productivity shows big difference even though its condition is similar to each terminal. The objective of this paper is to find the critical factors of container terminal productivity, which is dependant upon the capability, quantity of quay crane, transfer vehicle, and so on. For this purpose, we have researched related literatures, and collected data about container terminals in South Korea. Furthermore, we tested sensitive analysis to evaluate the extent of productivity by changing independent variable. And then we established the regression model to evaluate which factor has had the biggest impact on productivity. The results of this paper can give terminal operators guideline to improve productivity.

Shear Lag Phenomenon of Tube Structure with Core Wall in Relation to Nondimensional Structural Parameters (튜브-전단벽 구조의 무차원 구조변수에 따른 전단지연 현상)

  • 유은정;이강건;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.325-332
    • /
    • 2003
  • The tube structures act like cantilevered box beams and effectively resist lateral loads. In result, they are adopted as a high-rise buildings system. However, the shear lag in tube system prevents the idealized tube behavior such as a cantilevered box beam. Therefore, the studies on shear lag phenomena are necessarily requested. The presented papers are almost studied on framed tube structures and tube in tube structures. However, the study on the shear lag in the tube structure with core wall is lack. Thus, in this paper, the shear lag of the structure is studied. The shear lag coefficient is defined to investigate shear lag phenomena. However, existing shear lag coefficients are not adequate for understanding them. Therefore, on this study, new shear lag coefficient is suggested. In addition, the shear lag in the tube structure with core wall is analyzed by changing the five structural parameters of stiffness factor in frame, stiffness factor in wall, stiffness ratio, the number of stories and the number of bays.

  • PDF

A study on the influence factor for Quality Improvement Activity Performance of Enterprise (기업의 품질개선활동에 따른 성과에 영향을 주는 요인에 관한 연구 -싱글 PPM을 중심으로-)

  • Kim, Young-Beom;Jang, Gwang-Soon
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2011
  • Company's survival in a changing business environment is depend on what kind of strategy will be used for facing this business competition society. For this, many companies continued to apply management techniques to improve the activities in this process has been running productivity-oriented activities to switch away from the quality has become a central activity. In other words, quality improvement activities (quality improvement activity) for the continuing businesses is an important strategic element. In this study, single-PPM (Single-PPM) the company's leading quality improvement activities will be used and browse to accommodate factors that affect a successful quality improvement activities, absolute requirement for companies to learn about the conditions to improve the quality of corporate tries to emphasize the importance of the activity.

Analysis for luminescence property about an increase quantity of silicate phosphor and reliability (Silicate 형광체 증가에 대한 발광 특성 및 신뢰성 분석)

  • Yoon, Yanggi;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.12 no.4
    • /
    • pp.275-285
    • /
    • 2012
  • This paper presents a changes of luminescence property for converted white LEDs with the commercially available silicate phosphor. If silicate phosphor's quantity increase step by step. luminescence property will be changing. we analyze luminescence property for these change and carry out the high temperature aging test for 7,000 hours, the high temperature and humidity aging test for 7,000 hours for reliability. LED degradation not only results in reduced light output but also in color changes. so we monitor correlated color temperature (CCT), chromaticity coordinates(x, y) and spectrum intensity. Those results suggest that humidity factor more bad effect in color changes than temperature factor and Lighting quality is related with quantity of phosphor.

Sensorless MPPT Control using a Boost Converter and a Grid Side Inverter in Wind Power Generation Systems (Boost 컨버터와 계통연계 인버터를 이용한 풍력발전의 센서리스 MPPT 제어)

  • Kim, Do-Yoon;Lee, Jun-Min;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1372-1377
    • /
    • 2011
  • This paper proposes the control method of MPPT(maximum power point tracking) for the wind energy generation system using the duty ratio control of boost type DC-DC converter. For a lower cost and a higher reliability, the wind and the generator velocity sensors are removed. MPPT control is implemented by changing the duty ratio of the boost converter. Chain rule is applied by using each function. The grid side inverter is controlled to regulate unity power factor. The proposed control method was analyzed mathematically and verified by the computer simulation using PSIM.

Common Image Processing Techniques Comparison in Application (응용에서 영상처리 기술에 대한 비교)

  • Shin, Seong-Yoon;Jang, Dai-Hyeon;Rhee, Yang-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.612-613
    • /
    • 2010
  • The common image processing method treat the image as the array of pixels, and every pixel with its eight neighbors who directly around it form a square neighbor domain, sometimes may be more than that such as $5{\times}5$, or $7{\times}7$, and then adopt the convolution and template for every possible pixel value and then divide a attenuation factor, restrict the result in the area between 0 and 255, while the original and processed value record respectively. During the whole procedure, the result sole exist and represent the processing without changing the original pixel.

  • PDF

A High Efficiency Single-Phase AC-DC Boost Converter for Power Factor Correction (역률개선을 위한 고효율 교류-직류 승압형 변환기)

  • Park, Hae-Dong;Yoon, Duck-Yong;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.117-120
    • /
    • 1998
  • This paper proposes a new high efficiency single-phase AC-DC boost converter for power factor correction. Lossless commutation circuit is interposed in the proposed converter for soft-switching. Due to this commutation circuit, the converter operates in 9 mode. In spite of changing input voltage and load, It attracts a constant DC output voltage because of the PWM control scheme using both the output voltage feedback and the input voltage feedforward. The converter is suitable for high power applications and operates in continuous conduction mode. In this paper, a 2.4[kW] converter is designed and simulated.

  • PDF