• Title/Summary/Keyword: Change rate

Search Result 9,346, Processing Time 0.043 seconds

Epidemiologic Study of Frostbites and Its Current Managements in Community Hospital (지역 병원에서 동상 환자에 대한 역학에 관한 연구 및 최근 치료)

  • Kim, Dong Chul;Min, Byung Duk;Kim, Ji Hoon;Chung, Chang Eun;Lee, Chong Kun;Yu, Sung Hoon
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.21-29
    • /
    • 2021
  • Purpose: Frostbite is a hazard to people exposed to cold environments. With the progression of modern industrial development and change of leisure behavior encountering cold environments, frequent accidental exposure to frostbite injury during work and human behavior is increasing, and the predisposing factors of frostbite were greatly changed than before. The purpose of this study was to make epidemiological analysis, and to review the treatment outcomes of frostbite. Methods: From March 2010 to February 2021, this study has included 27 patients with second- to third-degree frostbite injuries in Advanced Burn Reconstruction Center, Bundang Jesaeng Hosptial. A retrospective study was made about the distribution of age, gender, predisposing factors, prevalent area, type of managements, and the length of treatment period. Results: In our institution, acute management of frostbite patients has included rewarming, anticoagulation therapy (acetylsalicylic acid), and agents to improve vascular perfusion (lipo-prostaglandin E1 [Eglandin®]). The 25 frostbite patients with second-degree frostbite (92.6%) were successfully managed by the conservative treatment alone with a mean of 20.3 days healing time. Two patients with third-degree frostbite (7.4%) also showed good outcomes after surgical reconstruction with a mean of 59 days healing time. In our clinical experiences of third-degree frostbite, definitive surgical reconstruction should be recommended to wait for more than 4~6 weeks for identification of clear demarcation of necrotic tissue caused by frostbite. In this study, 43 frostbite injuries site in 27 frostbite patients occurred. Among them, 15 patients (55.6%) had multiple-site frostbite injury. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments (40.8%), misapplying ice pack for treatment purposes (7.4%), barefoot walking on the cold ground (3.7%), and loss of consciousness in cold grounds (3.7%). The most prevalent sites of frostbite injuries revealed as the hand (58.1%), followed by the foot (32.6%), face (7.0%), and abdomen (2.3%). And in the winter season from the November to March, the incidence rate of frostbite injuries was high at 74.1%. Conclusion: This study included 27 frostbite patients with 43 frostbite sites since last decade in a single institution at the community hospital. The frostbite patients with second-degree frostbite (92.6%) were successfully healed by the conservative treatment alone with a mean of 20.3 days healing time. The most common predisposing cause of frostbite was refrigerant gas accidents (44.4%), followed by outdoor activity in cold environments, etc. The most prevalent site of frostbite injuries was the hand (58.1%). And the most prevalent seasonal incidence of frostbite was from November to March (74.1%).

A Study on the Development Direction of Medical Image Information System Using Big Data and AI (빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구)

  • Yoo, Se Jong;Han, Seong Soo;Jeon, Mi-Hyang;Han, Man Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.317-322
    • /
    • 2022
  • The rapid development of information technology is also bringing about many changes in the medical environment. In particular, it is leading the rapid change of medical image information systems using big data and artificial intelligence (AI). The prescription delivery system (OCS), which consists of an electronic medical record (EMR) and a medical image storage and transmission system (PACS), has rapidly changed the medical environment from analog to digital. When combined with multiple solutions, PACS represents a new direction for advancement in security, interoperability, efficiency and automation. Among them, the combination with artificial intelligence (AI) using big data that can improve the quality of images is actively progressing. In particular, AI PACS, a system that can assist in reading medical images using deep learning technology, was developed in cooperation with universities and industries and is being used in hospitals. As such, in line with the rapid changes in the medical image information system in the medical environment, structural changes in the medical market and changes in medical policies to cope with them are also necessary. On the other hand, medical image information is based on a digital medical image transmission device (DICOM) format method, and is divided into a tomographic volume image, a volume image, and a cross-sectional image, a two-dimensional image, according to a generation method. In addition, recently, many medical institutions are rushing to introduce the next-generation integrated medical information system by promoting smart hospital services. The next-generation integrated medical information system is built as a solution that integrates EMR, electronic consent, big data, AI, precision medicine, and interworking with external institutions. It aims to realize research. Korea's medical image information system is at a world-class level thanks to advanced IT technology and government policies. In particular, the PACS solution is the only field exporting medical information technology to the world. In this study, along with the analysis of the medical image information system using big data, the current trend was grasped based on the historical background of the introduction of the medical image information system in Korea, and the future development direction was predicted. In the future, based on DICOM big data accumulated over 20 years, we plan to conduct research that can increase the image read rate by using AI and deep learning algorithms.

Application of Greenhouse Climate Management Model for Educational Simulation Design (교육용 시뮬레이션 설계를 위한 온실 환경 제어 모델의 활용)

  • Yoon, Seungri;Kim, Dongpil;Hwang, Inha;Kim, Jin Hyun;Shin, Minju;Bang, Ji Wong;Jeong, Ho Jeong
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.485-496
    • /
    • 2022
  • Modern agriculture is being transformed into smart agriculture to maximize production efficiency along with changes in the 4th industrial revolution. However, rural areas in Korea are facing challenges of aging, low fertility, and population outflow, making it difficult to transition to smart agriculture. Among ICT technologies, simulation allows users to observe or experience the results of their choices through imitation or reproduction of reality. The combination of the three-dimension (3D) model and the greenhouse simulator enable a 3D experience by virtual greenhouse for fruits and vegetable cultivation. At the same time, it is possible to visualize the greenhouse under various cultivation or climate conditions. The objective of this study is to apply the greenhouse climate management model for simulation development that can visually see the state of the greenhouse environment under various micrometeorological properties. The numerical solution with the mathematical model provided a dynamic change in the greenhouse environment for a particular greenhouse design. Light intensity, crop transpiration, heating load, ventilation rate, the optimal amount of CO2 enrichment, and daily light integral were calculated with the simulation. The results of this study are being built so that users can be linked through a web page, and software will be designed to reflect the characteristics of cladding materials and greenhouses, cultivation types, and the condition of environmental control facilities for customized environmental control. In addition, environmental information obtained from external meteorological data, as well as recommended standards and set points for each growth stage based on experiments and research, will be provided as optimal environmental factors. This simulation can help growers, students, and researchers to understand the ICT technologies and the changes in the greenhouse microclimate according to the growing conditions.

Analysis of Spatial Characteristics of Vacant House in Consideration of the Modifiable Areal Unit Problem (MAUP) - Focused on the Old Downtowns of Busan Metropolitan City - (공간단위 수정가능성 문제(MAUP)를 고려한 빈집 발생지역의 특성 분석 - 부산광역시 원도심 일대를 대상으로 -)

  • SEOL, Yu-Jeong;KIM, Ji-Yun;KIM, Ho-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.120-132
    • /
    • 2022
  • Recently, the rapid increase in vacant houses in urban areas has caused various problems such as worsening urban landscape, causing safety accidents, crime accidents, and hygiene problems. According to the Statistics Korea Future Population Estimation results, the growth rate of Korean population and households is expected to continue to decrease, which is likely to lead to an increase in the occurrence of vacant houses. If the problem caused by the occurrence of vacant houses is neglected, it causes not only a physical decline such as a deterioration of the residential environment but also a social and economic decline. In order to solve this problem, it is necessary to grasp the spatial distribution characteristics of vacant houses at the local level considering the existence of regional characteristics and spatial influence. Therefore, in this study, in order to measure global spatial autocorrelation, the analysis was conducted centering on the old downtown area of Busan, where there are many vacant houses through Moran's I and Geographically Weighted Regression(GWR). In addition, the distribution of vacant houses in different spatial units in Eup_Myeon_Dong and Census was analyzed to evaluate the possibility of Modifiable Areal Unit Problem(MAUP), which differ in the results of spatial analysis as the spatial analysis units change. As a result of the analysis, the occurrence of vacant houses by Eup_Myeon_Dong in the old downtown area of Busan had spatial heterogeneity, and the spatial analysis results of vacant houses were different as the spatial analysis units were different. Accordingly, in order to understand the exact distribution characteristics of vacant house occurrence, spatial dimensions using the GWR model should be considered, and it is suggested that consideration of the MAUP is necessary.

Changes in Abscisic Acid and Gibberellin Levels during Stratification in Panax ginseng Roots (인삼근의 휴면타파과정에 있어서 Abscisic acid 함량 및 Gibberellin 활성의 변화)

  • Choi, Sun-Young;Lee, Kang-Soo;Ryu, Jeom-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.1
    • /
    • pp.7-13
    • /
    • 1989
  • The present study was carried out to get the basic information for clarifying physiological mechanism of breaking dormancy and sprouting in Panax ginseng roots. Changes in Abscisic acid (ABA) content and Gibberellin (GA) activity were investigated in one-year-old root during stratification at 4$^{\circ}C$. 15$^{\circ}C$. and 15$^{\circ}C$ after 60day-treatment at 4$^{\circ}C$. Sprouting rate at 15$^{\circ}C$ was 35% in 30days storage at 4$^{\circ}C$ and 100% in longer than 60days, but there was no sprout in both the constant treatment at 4$^{\circ}C$ or 15$^{\circ}C$ regardless of the treatment period. The longer the period of low temperature treatment. number of days to the first and 50% sprouting was shortened, and number of days to 50% from first sprouting was also shortened. ABA content in the upper part of root(contained bud) was gradually increased at both 4$^{\circ}C$ and 15$^{\circ}C$ as the treatment period was extended. and the degree of increase was higher at 15$^{\circ}C$. In the lower part. it showed a slight increase at 15$^{\circ}C$. while showed little change at 4$^{\circ}C$ throughout the treatment period. In the 15$^{\circ}C$ treatment after 60days at 4$^{\circ}C$, it was greatly increased in the upper part. while rather slightly decreased in the lower part of root. GA activity in the upper part was gradually decreased at both 4$^{\circ}C$ and 15$^{\circ}C$, and the degree of decrease was higher at 15$^{\circ}C$. In the lower part. it was similar tendency to those in the upper part. In the 15$^{\circ}C$ treatment after 60days at 4$^{\circ}C$. it was remarkably increased in both the upper and lower part. The increase was great in the low Rf region, while the decrease appeared relatively in the high Rf region compared to those of 60day-treatment at 4$^{\circ}C$. The above results indicated that the breaking dormancy and sprouting of bud were closely associated with the degree of GA activities in response to temperature condition .during stratification rather than the direct effect associated with the changes in ABA content.

  • PDF

Changes in chemical composition and physiological activity of Jeju-Tatary buckwheat tea according to leaching temperature (제주 타타리메밀의 침출 조건에 따른 제주 타타리메밀침출차의 이화학적 특성 및 생리활성)

  • Hyun-A Ko;Hyun Ju Park;Inhae Kang
    • Journal of Applied Biological Chemistry
    • /
    • v.65 no.4
    • /
    • pp.421-427
    • /
    • 2022
  • In this study, Jeju Tatary buckwheat tea's chemical composition and physiological activities were compared according to the leaching temperature (60, 80, 100 ℃). As the leaching temperature is increased, the degree of browning is induced. However, there was no significant change in pH. The total polyphenol content was higher at 80 ℃ than at 60 ℃ leaching temperature, but significantly decreased at 100 ℃ leaching temperature (60 ℃: 17.06 mg GA/g, 80 ℃: 20.09 mg GA/g, 100 ℃ :18.45 mg GA/g). There were high content of flavonoid and rutin as the leaching temperature increased. Consistently, 2,2-diphenyl1-picrylhydrazyl (DPPH) radical scavenging activity and tyrosinase inhibitory activity were significantly higher with increasing temperature (DPPH % inhibition: 60 ℃: 41.88%, 80 ℃: 46.01%, 100 ℃: 46.80%/tyrosinase inhibitory activity: 60 ℃: 9.38%, 80 ℃: 22.94%, 100 ℃: 28.17%). However, there was no significant difference in DPPH radical scavenging activity between 80 and 100 ℃. A cytotoxicity test was performed by treating with Jeju Tatary buckwheat extract into mouse macrophage cells (Raw264.7). 100 and 200 ㎍/mL treatment (100 ℃ extract) were significantly upregulated the survival rate, but there was no significant difference in other concentrations. Collectively, most of the bioactive components, antioxidant activity, and tyrosinase inhibitory activity were induced as the leaching temperature increased. However, the content of polyphenols which are known to have antioxidant activity, was significantly reduced at 100 ℃ leaching temperature. Several reports have demonstrated that leaching at too high temperature lowered the overall acceptability, so the optimal leaching condition of Tatary Buckwheat is 80 ℃, 5 min in this study.

Changes in Distribution of Debris Slopes and Vegetation Characteristics in Mudeungsan National Park (무등산국립공원의 암설사면 분포변화 및 식생 특성)

  • Seok-Gon Park;Dong-Hyo Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • We analyzed the distribution area of debris slopes in Mudeungsan (Mt. Mudeung) National Park by comparing aerial photos of the past (1966) and the present (2017) and identified the vegetation characteristics that affect the change in the area of the debris slopes by investigating the vegetation status of the debris slopes and the surrounding areas. The area of debris slopes in Mt. Mudeung appears to have been reduced to a quarter of what it used to be. Debris slopes here have decreased at an average rate of 2.3 ha/yr over 51 years by vegetation covers. Notably, most of the small-area debris slopes in the low-inclination slopes disappeared due to active vegetation coverage. However, there are still west-facing, south-west-facing, south-facing, and large-area debris slopes remaining because the sun's radiant heat rapidly raises the surface temperature of rock blocks and dries moisture, making tree growth unfavorable. Because of these locational characteristics, the small-scale vegetation in the middle of Deoksan Stony Slope, which is the broadest area, showed distinct characteristics from the adjacent forest areas. Sunny places and tree species with excellent drying resistance were observed frequently in Deoksan Stony Slope. However, tree species with high hygropreference that grow well in valleys with good soil conditions also prevailed. In some of these places, the soil layer has been well developed due to the accumulation of fine materials and organic matter between the crevices of the rock blocks, which is likely to have provided favorable conditions for such tree species to settle and grow. At the top of Mt. Mudeung, on the other hand, the forest covered the debris slopes, where Mongolian oaks (Quercus mongolica) and royal azaleas (Rhododendron schlippenbachii), which typically grow in the highlands, prevailed. This area was considered favorable for the development of vegetation for the highlands because the density of rock blocks was lower than in Deoksan Stony Slope, and the soil was exposed. Moreover, ash trees (Fraxinus rhynchophylla) and Korean maple trees (Acer pseudosieboldianum) that commonly appear in the valley areas were dominant here. It is probably due to the increased moisture content in the soil, which resulted from creating a depressive landform with a concave shape that is easy to collect rainwater as rock blocks in some areas fell and piled up in the lower region. In conclusion, the area, density of the rock blocks, and distribution pattern of rock block slopes would have affected the vegetation development and species composition in the debris slope landform.

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.

Colombia Border Area Refugees: Centered on Venezuela, Panama, and Ecuador Border Areas (콜롬비아 국경지역 난민증가 원인: 베네수엘라, 파나마 그리고 에콰도르 접경지역 강제실향민을 중심으로)

  • Cha, Kyung-Mi
    • Journal of International Area Studies (JIAS)
    • /
    • v.15 no.1
    • /
    • pp.109-134
    • /
    • 2011
  • Drug-related crime has increased in spite of visible results of Uribe government's hard-line policies on drug eradication and illegally armed organizations which were pursued under U.S. support, without the accompaniment of quantity change in drug cultivation and trade. Military disputes of left-right illegally armed communities surrounding illegal crop cultivation rights were rather intensified, and the number of refugees was increased through enforced displaced people. The 2005 refugee registration committee RUPD reports that 3,316,862 people, 7.3% of total population, were refugees. In particular, the number of refugees presented a large increase rate of 624% when compared to the past year due to enforced displaced people. Main discharge areas of enforced displaced people are connected with drug crime and activities of illegally armed organizations, and are places of increased armed disputes in the process of occupied territory expansion of illegally armed communities and militia. Undiscriminated attacks were executed on farmers in the process of occupation of illegal crop cultivation sites by illegally armed organization and militia to emit enforced displaced people, who moved to border areas by crossing national borders. Enforced displaced people were restricted to certain areas before the appearance of Uribe administration. However, enforced displaced people not only presented quantitative expansion, but also showed tendency of nationwide expansion after national security policy was pursued. With the closing of the Amazon area, previously the main route of drug trade, activity base of illegally armed organizations was moved to the Pacific region, and Panama border area experienced refugee increase due to the new policy of enforced displaced people. This study aims to understand the actual condition and cause for the increase in refugees in Colombia based on border areas of Venezuela, which is the nation of highest dispersion of Columbian refugees, Panama, which has appeared as a new destination for refugees after the 90s, and Ecuador, which has experienced sudden refugee increase in 2000.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.