• Title/Summary/Keyword: Change in oil price

Search Result 78, Processing Time 0.026 seconds

Extending the Storage Periods of Zanthoxylum schinifolium Seed Oil using Sodium Bicarbonate and Ascorbic Acid (중탄산나트륨과 아스코르브산을 이용한 산초유의 저장기간 연장)

  • Kim, Hak Gon;Kang, Seung Mi;Yong, Seong Hyeon;Seol, Yu Won;Kim, Do Hyeon;Park, Jun Ho;Yu, Chan Yeol;Choi, Myung Suk
    • Korean Journal of Medicinal Crop Science
    • /
    • v.28 no.6
    • /
    • pp.421-427
    • /
    • 2020
  • Morus alba, Anti-obesity, C57BL/6 Mice, Expression, Flavonoid, Gene, Mulberry Background: The seed oil of Zanthoxylum schinifolium S. et Z. (sancho) is a traditional cooking oil that has long been sold at a very high price however, depending on the method of extraction and storage, this oil becomes rancid occurs very quickly. Therefore, this study aimed to find a material that prevents rancidity and improves the storage properties of sancho oil. Methods and Results: Sancho oil was extracted using an extraction press, and acid values were compared with commercially available vegetable oils, sancho oil had a higher acid value than other vegetable oils. A very high acid value was observed in sancho oil stored for 6 months, regardless of temperature, requiring an effective storage method. The high acid value and the decrease in turbidity of sancho oil are dependent on the days of sedimentation. Treatment with sodium bicarbonate by concentration resulted in minimal changes in acid value over time. However, minor differences were detected among the treatment concentrations. Ascorbic acid was added to maximize the effect of sodium bicarbonate, and it was observed that ascorbic acid did not improve the antioxidant effect. The sodium bicarbonate and ascorbic acid mixture resulted in minimal change in acid value at temperature up to 25℃. Conclusions: Sancho oil becomes rancid very quicky and requires efficient storage techniques. Sodium bicarbonate and ascorbic acid have been proven to be useful as safe anti-racidity agents without causing harm to humans.

Calculation of Replacement Price for Alternative Feed Ingredient in Consideration of Nutrient Content in Feed Ingredient Fed to Broiler Chickens (영양소 함량을 고려한 육계 대체 원료사료의 대체가격 계산)

  • An, Su Hyun;Kong, Changsu
    • Korean Journal of Poultry Science
    • /
    • v.45 no.2
    • /
    • pp.73-79
    • /
    • 2018
  • The objective of this study was to calculate the unit price of an alternative feed ingredient for broiler chickens in consideration of the energy and nutritive contents in the feed ingredient by using a simple Excel worksheet. A corn-distiller's dried grains with solubles (corn-DDGS) was used as an alternative ingredient and corn and soybean meal as ingredients to be replaced. The net change of feed price was calculated based on the replacement values which were estimated in consideration of energy and nutrient concentration in feed ingredients used in the calculation, the price of feed ingredients and inclusion rate of the alternative ingredient. The nitrogen corrected apparent metabolizable energy(AMEn) and standardized ileal digestible AA including Lys, Met, Thr, and Trp, total Ca, and available P were employed as nutritive component to calculate the replacement values for individual feed ingredients. The equation for replacement was 1 ${\times}$ corn-DDGS + 0.0334 ${\times}$ soybean oil + 0.0182 ${\times}$ Limestone = 0.8893 ${\times}$ corn + 0.13 ${\times}$ soybean meal + 0.0004 ${\times}$ Lys + 0.0022 ${\times}$ Met + 0.0005 ${\times}$ Trp + 0.0028 ${\times}$ Thr + 0.0264 ${\times}$ dicalcium phosphate. The replacement price of corn-DDGS was calculated to be 270 won/kg when the inclusion rate was 15% and the energy and nutrient contents were considered in the calculation. In conclusion, the Excel-based ingredient price calculator may be useful to determine the economic value when an alternative feed ingredient is used in diets fed to broiler chickens.

Combustion Characteristics of a Hot Water Boiler System Convertibly Fueled by Rice Husk and Heavy Oil - Heavy Oil Combustion Characteristics -

  • Kim, Myoung Ho;Kim, Dong Sun;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.306-311
    • /
    • 2013
  • Purpose: With the ever-rising energy prices, thermal energy heavily consuming facilities of the agricultural sector such as commercialized greenhouses and large-scale Rice Processing Complexes (RPCs) need to cut down their energy cost if they must run profitable businesses continually. One possible way to reduce their energy cost is to utilize combustible agricultural by-products or low-price oil instead of light oil as the fuel for their boiler systems. This study aims to analyze the heavy oil combustion characteristics of a newly developed hot water boiler system that can use both rice husk and heavy oil as its fuel convertibly. Methods: Heavy oil combustion experiments were conducted in this study employing four fuel feed rates (7.6, 8.5, 9.5, 11.4 $l/h$) at a combustion furnace vacuum pressure of 500 Pa and with four combustion furnace vacuum pressures (375, 500, 625, 750 Pa) at fuel feed rates of 9.5 and 11.4 $l/h$. Temperatures at five locations inside the combustion furnace and 20 additional locations throughout the whole hot water boiler system were measured to ascertain the combustion characteristics of the heavy oil. From the temperature measurement data, the thermal efficiency of the system was calculated. Flue gas smoke density and concentrations of air-polluting components in the flue gas were also measured by a gas analyzer. Results: As the fuel feed rate or combustion furnace vacuum pressure increased, the average temperature in the combustion furnace decreased but the thermal efficiency of the system showed no distinctive change. On the other hand, the thermal efficiency of the system was inversely proportionally to the vacuum level in the furnace. For all experimental conditions, the thermal efficiency remained in the range of 80.1-89.6%. The CO concentration in the flue gas was negligibly low. The NO and $SO_2$ concentration as well as the smoke density met the legal requirements. Conclusions: Considering the combustion temperature characteristics, thermal efficiency, and flue gas composition, the optimal combustion condition of the system seemed to be either the fuel feed rate of 9.5 $l/h$ with a combustion furnace vacuum pressure of 375 Pa or a fuel feed rate of 11.4 $l/h$ with a furnace vacuum pressure between 500 Pa and 625 Pa.

Economic Analysis of Rural Green-Village Planning with Solar Energy considering Climate Change (기후변화를 고려한 농촌지역 그린빌리지의 태양에너지 활용에 관한 경제성 분석)

  • Kim, Dae-Sik;Wang, Young-Doo
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.25-36
    • /
    • 2013
  • This study aims to perform the economic analysis to the use of solar power facilities in rural villages considering the climate change scenario. IPCC climate change scenarios in the recently adopted the RCP scenarios (RCP8.5, RCP6.5, RCP4.5, RCP2.6) was used. By RCP scenarios, solar radiation, depending on the scenario in 2100, respectively, 3.6%, 2.5%, 1.9%, 1.1% was assumed to increase. From the economic analysis(payback period is 25 year) on 8 points of each province, in all cases of normal data and four RCP scenarios, at all points analyzed were NPV indicate a negative, BC ratio less than 1.0, respectively. In the case of Mokpo, Chunnam RCP8.5, BC ratio were found to be up to a 0.92, followed by 0.89 in the case of RCP8.5 in Jinju, Kyungnam shows, while the minimum was in Jeju. BC ratio is 1.0 or bigger, in order for the normal solar radiation data in Mokpo, Chonnam was the minimum that it takes 37 years. Similarly, in the case of RCP scenarios, 30 years in Mokpo, Chonnam RCP8.5 and 31 years in the cases of Jinju, Kyungnam and Jeonju, Cheonbuk RCP8.5 were analyzed. It was analyzed that RCP8.5 has the highest value. BC analysis models for each of the factors, the results of the sensitivity analysis, the initial installation costs, electricity sales price, discount rate in the order of economy showed higher sensitivity, and the rest factors showed lower changes. Although there are some differences of solar radiation by region, but in Korea most facilities in rural areas, the use of solar power was considered to be economical enough, considering change of several factors with high sensitivity, such as increasing of government subsidies for the solar power installation of the facility, rising oil prices due to a rise in electricity sales price, and a change in discount rate. In particular, when considering climate change scenarios, the use of solar energy for rural areas of the judgment that there was more economical.

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

Performance Analysis of OTEC Power Plant (해양온도차 발전 플랜트 성능해석)

  • Uhm, Ji-Hong;Lee, Jae-Yong;Kim, Nam-Jin;Kim, Chong-Bo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.234-240
    • /
    • 2000
  • The Energy is the basis for almost all industrial activities and domestic needs. But recently there are increasing concerns internationally over environmental problems and consequent climate changes caused by the excessive use of fossil fuels. Furthermore the price of crude oil is increasing steadily with unstable supplies. In order to solve these national energy problems, the utilization of Ocean Energy is introduced as one of the best alternative technologies for the future. OTEC Power Plant has been installed at the West Inchon Power Plant Site. Temperature differences of $20{\sim}25^{\circ}C$ have been utilized for plant operations, where R22 is used as a working fluid. The system is composed of low pressure turbine, plate type heat exchanger, and pumps. In the present investigation the experimental results, such as gross power, net power and objective function, are analysed when temperature differences change from the reference design point.

  • PDF

High Flux LED Garden Lamp Using PV Generation System (태양광 발전을 이용한 하이 플럭스 LED 정원등)

  • Choi, Guang-Soo;Jung, Doo-Yong;Kim, Jea-Hyung;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.445-448
    • /
    • 2008
  • There are increased interests in using new regeneration energy due to the effect of the latest rising oil price. On this account, various practical applications using small stand-alone PV generation system are being made. In this paper, with intent to change mercury lamp using for existing garden lamp with high flux LED, we have considered load characteristic using high flux LED modules applied to PV system. It is simulated with PSIM and made experiment set with a 75[W] solar cell module, DC-DC converter, controller and battery.

  • PDF

20kw급 해양온도차 파이롯 플랜트 성능실험

  • 엄지홍;이재용;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.1002-1008
    • /
    • 2001
  • The energy is the basis for almost all industrial activities and domestic needs. But recently there are increasing concerns internationally over environmental problems and consequent climate changes caused by the excessive use of fossil fuels. Furthermore the price of crude oil is increasing steadily with unstable supplies. In order to solve these national energy problems, the utilization of Ocean Energy is introduced as one of the best alterative technologies for the future. OTEC Power Plant has been installed at the West Inchon Power Plant Site. Temperature differences of$20~25^{\circ}C$ been utilized for plant operations, where R22 is used as a working fluid. The system is composed of low pressure turbine, plate type heat exchanger, and pumps. In the present investigation the experimental results, such as gross power, net power and objective function, are analysed when temperature differences change from the reference design point.

  • PDF

A Study on the Economics of Container Ships at Preliminary Design Stage (초기설계단계(初期設計段階)에서의 콘테이너선(船)의 경제성(經濟性)에 관한 연구(硏究))

  • Dong-Kon,Lee;S.I.,Ma
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.2
    • /
    • pp.1-7
    • /
    • 1984
  • This paper is concerned with an optimum design study of containerships in preliminary stage by applying economic criteria. The Net Present Value Index (NPVI) and the Required Freight Rate(RFR) are used as measures of merit. Hooke & Jeeves direct search method and External Penalty Function method of Sequential Unconstrained Minimization Techniques(SUMT) are used for solving constrained nonlinear optimization problem. Sensitivity analysis is carried out to investigate the effect on the optimum solution due to change of values in some parameters such as crane capacity, load factor, oil price, ship speed and the ratio between loaded FEU and TEU.

  • PDF

A Study on the Optimal Service Level of Exclusive Container Terminals (컨테이너 전용부두의 최적 서비스 수준에 관한 연구)

  • Park, Sang-Kook
    • Journal of Korea Port Economic Association
    • /
    • v.32 no.2
    • /
    • pp.137-156
    • /
    • 2016
  • This study analyzes the optimal service levels of exclusive container terminals in terms of the optimal berth occupancy rate and the ships' waiting ratios, based on the number of berths. We develop a simulation model using berth throughput data from pier P, Busan New Port, a representative port in Korea, and apply the simulation results to different numbers of berths. In addition to the above results, we analyze the financial data and costs of delayed ships and delayed cargoes for the past three years from the viewpoints of the terminal operation company (TOC), shipping companies, and shippers to identify the optimal service level for berth occupancy rates that generate the highest net profit. The results show that the optimal levels in the container terminal are a 63.4% berth occupancy rate and 10.6% ship waiting ratio in berth 4,66.0% and 9.6% in berth 5, and 69.0% and 8.5% in berth 6. However, the results of the 2013 study by the Ministry of Maritime Affairs and Fisheries showed significantly different optimal service levels: a 57.1% berth occupancy rate and 7.4% ship waiting ratio in berth 4; 63.4% and 6.6% in berth 5; and 66.6% and 5.6% in berth 6. This suggests that optimal service level could change depending on when the analysis is performed. In other words, factors affecting the optimal service levels include exchange rates, revenue, cost per TEU, inventory cost per TEU, and the oil price. Thus, optimal service levels can never be fixed. Therefore, the optimal service levels for container terminals need to be able to change relatively quickly, depending on factors such as fluctuations in the economy, the oil price, and exchange rates.