• Title/Summary/Keyword: Change Factor

Search Result 4,684, Processing Time 0.03 seconds

A study on the Plan for Organization Activation use analysis of Success factor Integration Information System (통합정보시스템 구축 프로젝트 성공 요인 분석을 통한 조직 활성화 방안에 대한 연구)

  • Park, Jong-Ki;Kang, Kyong-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.231-242
    • /
    • 2006
  • Since 1990's, many enterprises have constructed Integration Information System. Especially, they want to become an advanced company use ERP package. Already, ERP system come to high level which is stabilized and support independent business process of many industry sectors. Therefore, important success factors for ERP project are change management and organization activation. Although most companies had previous good plans, but those are not satisfied. Because of failed to change management and discontinued next activity for promotion. This paper studied success factors of project team and plan for organization activation. Also, it proposed next study subject about investigate the role of the member of task force team as a factor that makes the ERP system a success. The results of this study can be used for a successful construction of the ERP system as a solution about Internal problems of Project team.

An Empirical Study on the Influence of Change Management Factors on the Change Management Maturity and Successful Information Systems (변화관리요인이 변화관리성숙도와 정보시스템의 성공적 수행에 미치는 영향에 관한 실증적 연구)

  • Kim, Young-Gon
    • Journal of Information Technology Services
    • /
    • v.9 no.1
    • /
    • pp.1-25
    • /
    • 2010
  • Many organizations are facing larger and more frequent changes in the current economic and managerial environment. And what is more, change is supposed to be a business as usual. Considering the importance of change management process and the organizational competency to rapidly and successfully change, in this study the components of change management maturity(CMM) was selected such as the leadership, communication, resistance, people culture factor, methodology, functional group, and change review. And information system performance affected by CMM is confined to the efficiency and effectiveness of information systems. Some results from the verification of research hypotheses and the analysis of the most appropriate model was drawn out. The result of this study can be applied to all organizations which plan to manage more successful change and implement more effective information systems.

Effect of Atrial Natriuretic Factor on the Renal Function and Renin Release in Unanesthetized Rabbit (무마취 가토 신장기능에 미치는 Atrial Natriuretic Factor의 영향)

  • Lee, June-K.;Cho, Kyung-W.
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.103-124
    • /
    • 1986
  • Since it has been suggested that atrial receptor may be involved in the mechanism of extracellular volume regulation, it was shown that the granularity of atrial cardiocytes can be changed by water and salt depletion, and that an extract of cardiac atrial tissue, when injected intravenously into anesthetized rats, was shown to cause a large and rapid increase in renal excretion of sodium. Various natriuretic peptides were isolated and synthetized, and the effects were investigated by many workers. Most studies, however, have been carried out under anesthesia and there have teen some controversies over direct effect of the factor on the renal function. Therefore, it was attempted in this study to access the effects of an atrial extract and a synthetic natriuretic factor in unanesthetized rabbits. Intrarenal arterial infusion of atrial extract caused a rapid increase of urinary volume and excretion of sodium. Glomerular filtration rate and renal plasma flow were both increased with no change in filtration fraction. The ventricular extract produced no change in urinary excretion of electrolytes, nor in renal hemodynamics. Intrarenal infusion of synthetic atrial natriuretic factor caused increases of renal excretory rate of sodium, chloride and potassium, and $FE_{Na}$. Glomerular filtration rate, renal plasma flow increased. And free water clearance also increased. Accentuated excretory function correlated well with increased glomerular filtration rate and renal plasma flow during infusion and for 10 minutes following the cessation of the infusion. Renin secretion rate decreased during constant infusion of atrial natriuretic factor. However, no correlation was found with the changes in glomerular filtration rate, renal plasma flow, or urinary excretion of sodium. These results suggest that atrial extract or atrial natriuretic factor induces changes in renal hemodynamics, as in excretion of electrolytes either indirectly through hemodynamic changes or directly by inhibiting tubular reabsorption. At the same time, renin secretory function is affected by the factor possibly through an unknown mechanism.

  • PDF

Analytical study on safety factor of concrete pole installed in sloped ground (콘크리트 전주의 경사지 전도 안전율에 관한 해석 연구)

  • Shin, Dong-Geun;Yoon, Ki-Yong;Lee, Seung-Hyun;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.433-436
    • /
    • 2007
  • We analyzed the sloped ground safety factor, which is not presented in the design specification, using a computational analysis program L-Pile Plus 13.8. To achieve this we chose a required parameter set and a level ground safety factor presented in the design specification, and then determined its values comparing with the change of the safety factor according to the parameter. Using these parameters, we estimated the sloped ground safety factor for the slope of 35 degrees considering the improvement value of the slope presented in the design specification. As a result of this analysis, we obtained the smaller safety factor by about 0.7 times than the case of the level ground and verified that a number of concrete poles fail to assure 1 degree of the safety factor. We, therefore, concluded that an adjustment of the embedment depth is required in the case of the sloped ground.

  • PDF

통계분석을 이용한 지하수위 변동 특성 분류

  • 문상기;우남칠
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.155-159
    • /
    • 2001
  • A study on multivariate statistical classification of ground water hydrographs was conducted. The vast data of national ground water monitoring network (78 sites of alluvium) were used. 6 factors were selected to classify the ground water level change. Factor analysis was proved to be useful tool for classifying vast hydrogeological data.

  • PDF

Developmental Competence of Intrafollicular Oocytes Derived from Preantral Follicle Culture with Different Protocols after Parthenogenetic Activation

  • Choi, Jung Kyu;Lee, Jae Hee;Lee, Seung Tae;Choi, Mun Hwan;Gong, Seung Pyo;Lee, Eun Ju;Lim, Jeong Mook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.8
    • /
    • pp.1190-1195
    • /
    • 2007
  • This study was conducted to improve efficiency of a follicle culture system without reducing developmental competence of intrafollicular oocytes. Preantral follicles (100 to $125{\mu}m$ in diameter) of F1 hybrid (B6CBAF1) mice were cultured singly for 216 h in modified ${\alpha}$-MEM-glutamax medium, to which 2.5 IU/ml hCG and epidermal growth factor was added 16 h prior to the end of culture. Medium change was either performed three times (54 h interval), twice (72 h interval), once (108 h interval), or not at all (216 h interval). Maturation (progression to the metaphase II stage) of intrafollicular oocytes was detected from 4 days after culture in the three-times change treatment, while all treatments yielded mature oocytes from day 5 of culture. Compared with the three-times change, decreasing the change frequency to once did not reduce the capacity to begin maturation (germinal vesicle breakdown of 82 to 86%), to mature (78 to 79%) and to develop into blastocysts after parthenogenetic activation (29 to 32%). Morphological parameters were similar among these treatments. Except for the no medium change treatment, similar colony-forming activity of inner cell mass cells after culturing of blastocysts in leukemia inhibitory factor-containing medium was detected, while the morphology of the colony-forming cells deteriorated in the change-once treatment compared with the change twice or three-times. In conclusion, the efficiency of the preantral follicle culture system could be improved by reducing frequency of medium change up to a 72 h interval (three times in total 216 h culture) without decreasing developmental competence of oocytes.

A Comparison of the Changes of Greenhouse Gas Emissions to the Develop Country-Specific Emission Factors and Scaling Factors in Agricultural Sector (농업부문 국가 고유 배출계수와 보정계수 개발에 따른 온실가스 배출량 변화 비교)

  • Jeong, Hyun Cheol;Lee, Jong Sik;Choi, Eun Jung;Kim, Gun Yeob;Seo, Sang Uk;So, Kyu Ho
    • Journal of Climate Change Research
    • /
    • v.5 no.4
    • /
    • pp.349-357
    • /
    • 2014
  • Greenhouse gases (GHGs) from agricultural sector were categorized in a guideline book from Intergovernmental Panel on Climate Change (IPCC) as methane from rice paddy fields and nitrous oxide from agricultural soils. In general, GHG emissions were calculated by multiplying the activity data by emission factor. Tier 1 methodology uses IPCC default factors and Tier 2 uses country specific emission factors (CS). The CS and Scaling factors (SF) had been developed by NAAS (National Academy of Agricultural Science) projects from 2009 to 2012 to estimate how the advanced emissions. The purpose of this study was to compare GHG emissions calculated from IPCC default factors and NAAS CS and SF of agricultural sector in Korea. Methane emissions using CS and SF in rice paddy field was about 79% higher than those using IPCC default factors. In the agricultural soils, nitrous oxide emissions using CS from the 5 crops were about 40% lower than those using IPCC default. Except those 5 crops, approximately up to 52% lower emissions were calculated using CS compared to those using IPCC default factors. The total GHG emissions using CS and SF were about 33% higher than those using Tier 1 method by IPCC default factors.

Conceptual Change: An Interpretation by Cybernetics (II) (개념변화: 사이버네틱스 관점에 의한 해석(II))

  • Yoo Pyoung-Kil
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.4
    • /
    • pp.417-425
    • /
    • 2005
  • Although there are some challenges to a view of science teaming as conceptual change, the view still occupies an important position in science teaming and teaching. Conceptual change theory implies that students' conceptions need to be exchanged for the new science conceptions. This was at the heart of conceptual change theory of Posner et al. (1982). According to this theory, cognitive conflict is known as an important factor in conceptual change even though there is still a controversial on effects on science teaming. This study is intended to interpret the cognitive conflict from cybernetics' perspective and explain difficulties of conceptual change which students have in teaming science and the conditions of conceptual change.

  • PDF

Deduction and Management of Change Order Management Factors through Dispute Case Analysis - Focusing on Korean Commercial Arbitration Board Arbitration Case - (설계변경 분쟁 사례분석을 통한 설계변경 관리요인 도출 및 관리방안 - 대한상사중재원 중재 사례 분석 중심 -)

  • Yeon, Heejung;Hyun, Chang-Taek;Lee, Sanghoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.365-366
    • /
    • 2023
  • The purpose of this study is to prevent dispute due to change orders in construction projects and to handle change orders smoothly. For this purpose, this study analyzed arbitration cases caused by change order handled by the Korea Commercial Arbitration Board. Based on this, dispute factors were analyzed and change order management factors and management plans were presented. Change order management factors were derived from responsibility, contract, design, process, construction cost, and schedule management, and a detailed management plan according to the relevant factor was presented.

  • PDF

Investigation of dynamic P-Δ effect on ductility factor

  • Han, Sang Whan;Kwon, Oh-Sung;Lee, Li-Hyung
    • Structural Engineering and Mechanics
    • /
    • v.12 no.3
    • /
    • pp.249-266
    • /
    • 2001
  • Current seismic design provisions allow structures to deform into inelastic range during design level earthquakes since the chance to meet such event is quite rare. For this purpose, design base shear is defined in current seismic design provisions as the value of elastic seismic shear force divided by strength reduction factor, R (${\geq}1$). Strength reduction factor generally consists of four different factors, which can account for ductility capacity, overstrength, damping, and redundancy inherent in structures respectively. In this study, R factor is assumed to account for only the ductility rather than overstrength, damping, and redundancy. The R factor considering ductility is called "ductility factor" ($R_{\mu}$). This study proposes ductility factor with correction factor, C, which can account for dynamic P-${\Delta}$ effect. Correction factor, C is established as the functional form since it requires computational efforts and time for calculating this factor. From the statistical study using the results of nonlinear dynamic analysis for 40 earthquake ground motions (EQGM) it is shown that the dependence of C factor on structural period is weak, whereas C factor is strongly dependant on the change of ductility ratio and stability coefficient. To propose the functional form of C factor statistical study is carried out using 79,920 nonlinear dynamic analysis results for different combination of parameters and 40 EQGM.