• Title/Summary/Keyword: Chang-Pu

Search Result 114, Processing Time 0.021 seconds

Comparative Studies on Ammonium Ion Selective Electrodes Using Poly(Vinyl Chloride) and Polyurethane as Substrate Matrix Materials (Poly(Vinyl Chloride)와 Polyurethane을 지지체로 사용한 암모늄이온 선택성 전극의 특성비교)

  • Cho Chang-Ae;Park Su-Moon
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.148-154
    • /
    • 2004
  • Ammonium ion selective electrodes have been prepared using nonactin as an ionophore and poly(vinyl chloride) (PVC) or polyurethane(PU) as a polymer matrix with or without a plasticizer, bis(2-ethylhexyl) adipate, and their performances have been evaluated. The reults indicate that PU-based electrodes can be designed to perform better although PVC-based electrodes generally show better performances. In efforts to explain the obervation, we also carried out atomic force microscopy as well as impedance studies, and the results suggests that islands of ion-ophores are formed in the PVC membranes through which ion transfers appear to be more facile than through the PU membranes. The PU membranes appear to have ionophores better dispersed throughout the film and are more resistive to ion mobilities in comparison to PVC films.

Preparation and Characterization of Polyurethane/Organoclay Nanocomposites by UV Curing (UV경화에 의한 폴리우레탄/유기화클레이 나노복합재료 제조와 물성 연구)

  • Shin, Geumsig;Chang, Young-Wook;Kim, Seong Woo
    • Journal of Adhesion and Interface
    • /
    • v.13 no.4
    • /
    • pp.156-162
    • /
    • 2012
  • Polyurethane (PU)/organoclay nanocomposites were prepared by mixing UV curable urethane acrylate oligomer with organoclay, and a subsequent curing by UV irradiation. As organoclays, commercially available Cloisite 20A (C20A) and acrylsilane modified C20A were used. XRD and TEM analyses revealed that the UV cured PU/clay nanocomposites formed intercalated nanocomposites, and acrylsilane modified C20A are dispersed more finely than unmodified C20A in PU matrix. DMTA, pencil hardness and adhesion test onto PET substrate showed that the clay nanolayers induced an increase in the properties, and the enhancement in the properties was more pronounced in the PU/acrylsilane modified C20A nanocomposites than in the PU/unmodified C20A nanocomposites. It was also observed that the PU/surface modified clay nanocomposites showed remarkably lower shrinkage upon UV curing than the unfilled PU. The nanocomposites showed excellent optical transparency but lower gloss as compared to unfilled PU.

Estimation of Discharged Amounts of U and Pu Nuclides from the PWR Spent Fuels in Korea (국내 가압 경수형 원자로의 사용후 핵연료에서 잔류하는 U과 Pu핵종의 발생량 추정)

  • Lim, Chae-Jun;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.165-169
    • /
    • 1988
  • As a part of tandem fuel cycle feasibility study, the residual U and Pu nuclide contents of PWR spent fuels are computed using ORICEN2 code for each Korea Nuclear Unit and batch to investigate the potential of utilizing them as CANDU fuels. The annual and accumulated discharged amounts of U and Pu nuclides are computed for the PWRs from KNU 1 through KNU 10. The results of computation show that the spent fuels having 0.7-0.8 w/o U-235 are dominant and considerable amounts of fissile Pu are produced. The enrichment of U-235 is less than the expected 0.8-0.9 w/o U-235 since the burnups offered by KEPCO are higher than those of other PWRs.

  • PDF

A Study on the Physical Properties and Adhesion Characteristics of Polyurethane Resin (폴리우레탄 수지의 물성 및 접착특성에 관한 연구)

  • Kim, Young-Joon;Chang, Ki-Young;Kim, Gu-Ni;Chun, Yong-Chul;Yoo, Chong-Sun;Park, Sang-Wook
    • Elastomers and Composites
    • /
    • v.31 no.2
    • /
    • pp.104-110
    • /
    • 1996
  • The polyurethane was synthesized by the reaction of polycaprolactone diol(Mw 2000), 4,4'-diphenylmethane diisocyanate and 1,4-butanediol as the chain extender. Also, the modified polyurethane polymers based on liquid polybutadiene as a part of soft segment and dimethylolpropionic acid as a chain extender, giving polyurethane with various polarity, were synthesized. The thermal, mechanical, adhesion properties and water contact angles of the polyurethanes were examined. From the result of the water contact angle, the polarity of the acid modified PU containing 6% acid content was unchanged but mechanical and adhesion properties were improved. The water contact angles on polybutadiene modified PU films were increased with increasing polybutadiene content. The mechanical properties of the polybutadiene modified PU were higher than that of acid modified PU. However, the mechanical properties were reduced as polybutadiene content increased. The result is presumably due to phase separation between hard segment and soft segment. The peel strength of the polyurethane introduced with 5wt% polybutadiene was improved about 150% than that of unmodified PU. The same as the mechanical properties, the more polybutadiene was introduced, the lower peel strength was obtained.

  • PDF

The Effect of Ionic Group and MMA Contents on the Physical Properties of PU/PMMA Hybrids (PU/PMMA Hybrids의 물성에 대한 이온성기와 MMA함량의 영향)

  • Jeong, Chang Nam;Cho, Hang Kyu;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.575-581
    • /
    • 1997
  • UDs were synthesized from two different polyols(PTMG, PBEAG), ionic chain extender(DMPA), EDA with $H_{12}-MDI$. PU/PMMA hybrids were prepared with free radical polymerization of MMA monomer in MMA-swelled PUD. PUD particle size and film properties were investigated ionic content and polyol type. Mechanical and thermal properties of PU/PMMA hybrid film were studied in terms of PU's ionic content and the venation of PU/PMMA compositions. As DMPA content increased from 2wt% to 10wt% in PUD, particle size of PUD decreased. PUD's particle size with ester type polyol was found to be smaller then ether type polyol used. Phase separation between hard segment(HS) and soft segment(SS) with ionic contents in PU was shown by the thermal, mechanical property measurement. Although the composition of MMA was changed from 0 to 40 wt% in PU/PMMA hybrid, the particle size of the hybrid did not increase. Using the ester type polyol, tensile strength of hybrid was found to increase by 2wt% - 6wt% DPMA content, but as higher content the strength of hybrid decreased. Moreover with the ether type polyol, tensile strength of hybrid was observed to increase by 2wt% - 4wt% DMPA content, while decreasing at higher content. PU and PMMA polymer molecule being mixed in molecular level was confirmed from the pattern of $T_g$ in DSC thermogram.

  • PDF

Study on Reliability of Interpretation and Reproducibility of a Pulse Analyser (맥진기 판독의 신뢰도 및 파형의 재현성 연구)

  • Park, Seung-Chan;Lee, Ji-Hye;Lee, Hye-Yoon;Cho, Min-Kyoung;Kim, Do-Hyung;Kim, So-Yeon;Choi, Jun-Yong;Han, Chang-Woo;Park, Seong-Ha;Hong, Jin-Woo;Lee, In;Kwon, Jung-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.

Recycling of PC/ABS Blend Used in Instrument Panel of Automotive (자동차 Instrument Panel에 사용된 PC/ABS계의 재활용)

  • Lee, Chang Hyung;Jung, In Kwon;Lee, Yong Moo;Oak, Sung Hyun;Choi, Hyeong Ki
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.118-123
    • /
    • 1999
  • The recycle of the polycarbonate(PC)/acrylonitrile-butadiene-styrene(ABS) separated from the instrument panel (In-Panel) of the automotive was investigated. The small amount of polyurethane(PU) foam contained in the separated PC/ABS decreased the mechanical properties of the recycled PC/ABS. However, it is found that the PU foam formed the dispered phase of small particles at high temperature ($260^{\circ}C$) under high shear of the twin extruder, whereas it formed the big particles at low extrusion temperature ($220^{\circ}C$). The mechanical properties of the recycled PC/ABS extruded at high temperature was better than those at low temperature, which enabled the recycled PC/ABS seperated from In-Panel to be applied to the radiator grille without the addition of the compatibilizers or virgin PC/ABS. This was ascribed to the smaller particle sizes of the PU foam formed at high extrusion temperature under high shear.

  • PDF

Overview of the Interaction between Warfarin and Korean Herbal Medicine (와파린과 상호작용하는 한약재에 대한 고찰)

  • Lee, In;Park, Sang-Moo;Park, Seung-Chan;Kim, Do-Hyung;Cho, Min-Kyoung;Han, Chang-Woo;Kwon, Jeong-Nam;Hong, Jin-Woo
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.2
    • /
    • pp.160-171
    • /
    • 2012
  • Background and Objective : Warfarin is the standard anticoagulation treatment for atrial fibrillation, venous thromboembolism (VTE), and mechanical heart valves. Close monitoring of the International Normalized Ratio (INR) is required due to the drug's very narrow therapeutic window. Many factors can affect INR levels. Drug and food interactions are frequently cited as causes of adverse events with warfarin. We discussed interactions between herbs and warfarin studied in this research. Methods : In this review, PubMed was used to search medical journals. Keywords "warfarin AND interaction" were applied. Results : 55 articles were included. The possibility of correlation between warfarin and single herbal medicines such as Salviae Miltiorrhizae Radix, Angelicae Gigantis Radix, Ginseng Radix Alba, Lycii Fructus, Ginkgo Folium, Menthae Herba, Trigonellae semen was suggested. Furthermore, some herbal compounds interacting with warfarin were reported. The conclusion of studies reporting the effect of herbal medicine on warfarin were controversial due to small size or quality of research. Conculsions : We suggest that we should prescribe therapeutic herbal medicines to patients using warfarin more carefully and do INR follow-up regularly.

DETERMINATION OF THE TRANSURANIC ELEMENTS INVENTORY IN HIGH BURNUP PWR SPENT FUEL SAMPLES BY ALPHA SPECTROMETRY

  • Joe, Kih-Soo;Song, Byung-Chul;Kim, Young-Bok;Han, Sun-Ho;Jeon, Young-Shin;Jung, Euo-Chang;Jee, Kwang-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.673-682
    • /
    • 2007
  • The contents of transuranic elements in high-burnup spent fuel samples were determined. The activity amounts of $^{238}Pu,\;^{239}Pu,\;^{240}Pu,\;^{241}Am,\;^{244}Cm\;and\;^{242}Cm$ were measured by alpha spectrometry using $^{242}Pu\;and\;^{243}Am$ as tracers, respectively. A spike addition method for $^{237}Np$ was established by an alpha and gamma spectrometry using $^{239}Np$ as a spike after the optimum conditions for the measurements of $^{237}Np\;and\;^{239}Np$, respectively, were obtained. A separation system using anion exchange chromatography and diethylhexylphosphoric acid extraction chromatography was applied for the separation of these elements. This method was applied to high-burnup spent nuclear fuel samples $(40{\sim}60GWD/MTU)$. The contents of the transuranic elements were compared with those by ORIGEN-2 code. Measurements and the calculations of the contents of the plutonium isotopes $^{238}Pu,\;^{239}Pu\;and\;^{240}Pu$ agreed to within 10% on average. The contents of $^{237}Np$ agreed to within approximately 5% except for one instance of a calculation, while those of $^{241}Am,\;^{244}Cm\;and\;^{242}Cm$ showed higher values by approximately 19%, 35% and 14% on average, respectively, compared to the calculations according to the burnup.

A Sensitive Detection of Actinide Species in Solutions Using a Capillary Cell (모세관 셀을 이용한 수용액 내 악티나이드 화학종의 고감도 검출)

  • Cho, Hye-Ryun;Park, Kyuong-Kyun;Jung, Euo-Chang;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Absorption spectra for a quantitative analysis of actinide elements such as U(VI) and Pu(V) were measured by using a liquid waveguide capillary cell (LWCC) which has an optical path length of 1.0 meter. In order to investigate radioactive elements, a LWCC is installed in a glove box and is coupled to a spectrophotometer with optical fibers. Limits of detection (LOD) for the system were determined as 0.74 and 0.35 M with molar absorption coefficients of 8.14${\pm}$0.07 (414 nm) and 17.00${\pm}$0.16 (569 nm) $M^{-1}cm^{-1}$ for U(VI) and Pu(V) ions, respectively. The measured LOD values are about 30 times more sensitive when compared to those achievable by using a conventional quartz cell with an optical path length of 1.0 cm. As an application with an enhanced sensitivity, a quantitative analysis for micromolar concentrations of Pu(V) has been performed to decrease the uncertainty in the formation constant of the Pu(VI)-OH complex.

  • PDF