• 제목/요약/키워드: Chamfer

검색결과 152건 처리시간 0.02초

유한요소법을 이용한 서비스 로봇관절용 외전형 BLDC 모터설계에 관한 연구 (A Study of Design of Outer Rotor Type BLDC Motor for Service Robot Arm)

  • 김영균
    • 한국자기학회지
    • /
    • 제25권6호
    • /
    • pp.198-202
    • /
    • 2015
  • 본 논문은 서비스 로봇관절 구동에 적용되는 50W급 외전형 BLDC 전동기 의 코깅토크 최소화 설계에 관하여 기술하였다. 코깅 토크 저감 설계를 위해서 반응표면법을 이용하였으며, 반응표면법에 사용되는 관측자료는 유한요소법을 이용하였다. 끝으로 설계결과에 대한 타당성은 실험을 통해서 검증하였다.

고속탭핑에 있어서 절삭토크에 관한 연구 (A Study on Tapping Torque in High Speed Tapping)

  • 최만성
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3195-3201
    • /
    • 1994
  • In order to analytically predict tapping torque and thrust force in high speed tapping, a cutting model for main cutting edge with a uniformly restricted tool-chip contact area were developed. From this model equations are derived for the prediction of tapping torque given the cutting conditions, tap geometry, and an empirical factor which is related to the workmaterial. Computed values of torque is shown to compare favorably with those obtained from tapping tests on 16MnCr5. The applied torque about the cutting edge of teeth at lead chamfer is estimated respectively and it is shown that observed value is gradually decreased with following teeth.

자동차용 차동 베벨기어의 최적 예비성형체 설계 (The Optimal Preform Design for Automotive Differential Bevel Gear)

  • 김병민;김동환;정구섭
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.184-189
    • /
    • 2004
  • In this paper, the warm forging process sequence has been determined to manufacture the warm forged product for the precision bevel gear used as the differential gear unit of a commercial automobile. The preform shape of bevel gear influences the dimensional accuracy and stiffness of final product. The aspect ratio and chamfer length are considered as design parameters to achieve adequate metal distribution in the finish forging operation. Then the optimal conditions of design parameters have been selected by artificial neural network (ANN). Finally, to verify the optimal preform shape, the experiments of the warm forging of the bevel gear have been executed. The proposed method can give more systematic and economically feasible means for designing the preform shape in metal forming process.

CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구 (A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK)

  • 전미현;전영찬;정창모;임장섭;정희찬
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

절단피개량과 절단변연형태 및 하중각도가 도재라미네이트 베니어 내의 응력분포에 미치는 영향에 관한 삼차원 유한요소법적 연구 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION IN PORCELAIN LAMINATE VENEERS WITH VARIOUS AMOUNTS OF INCISAL COVERAGE AND TYPES OF INCISAL FINISH LINE UNDER TWO LOADING CONDITIONS)

  • 류경희;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.143-166
    • /
    • 1999
  • The success of porcelain laminate veneer depends on the bond strength between tooth structure and ceramic restoration and the design of tooth preparation. In particular, incisal coverage and incisal finish line are the two most important factors in long-term fracture resistance. Although the majority of clinicians are practicing incisal coverage and there are various opinions on the geo-metrical ratio between the clinical crown length of the remaining tooth structure and the length of incisal extension in porcelain laminate veneer and the optimal incisal finish lines. scientific evidence still loaves much to be desired. The purpose of this study was to determine the effects of the amounts of incisal coverage and the types of incisal finish line on the stress distribution in maxillary anterior porcelain laminate veneers under two different loading conditions. Three-dimensional finite element models of a maxillary anterior porcelain veneer with differ-ent amounts of incisal coverage ; 0, 1, 2, and 3mm and different incisal finish lines feathered edge, incisal bevel, reverse bevel and lingual chamfer with various amounts of lingual extension were developed. 300N force was applied at the point 0.5mm cervical of the linguoincisal edge in two loading conditions ; A) 125 degrees, B) 132 degrees. Tensile and compressive stress in ceramic and shear stress in the resin cement layer were analyzed using three-dimensional finite element method. The results were as follows : 1. The types of incisal finish line had more influence on the stress distribution in porcelain laminate veneer than the amounts of incisal coverage. 2. In case of no incisal coverage, incisal beveled laminate exhibited more evenly distributed tensile stress than feathered edged laminate. And in case of incisal coverage, reverse beveled laminate and lingual chamfered laminate with 1mm lingual extension exhibited more evenly distributed tensile stress than lingual chamfered laminates with 2mm and 3mm lingual extension. 3. As long as the lingual chamfer goes, less tensile stress was found at the incisal edge, while much more tensile stress was found at the lingual margin area in proportion to the length of lingual extension. 4. Under 125 degree load, tensile stress in porcelain laminate veneer had increased compared with that under 132 degree load and the difference exhibited by the change of the amount of tooth support was larger. 5. The types of incisal finish line and the distance from the incisal finish line to the loading point had more influence on the shear stress distribution in the resin cement layer than the amounts of incisal coverage. In contrast loading condition had little influence.

  • PDF

유한요소법을 이용한 전부주조관의 교합점 위치와 하중방향이 시멘트층 내 응력에 미치는 영향 (Characterization of the Stresses in the Luting Cement Layer Affected by Location of the Occlusal Points and Loading Direction on a Full Veneer Crown)

  • 이정훈;이규복;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.317-324
    • /
    • 2008
  • 이 논문의 목적은 전부주조관에서 교합점의 위치와 교합력의 방향이 합착용 시멘트층 내의 응력에 미치는 영향에 대해서 알아보는 것이다. 하악 제 1대구치상에서 서로 다른 9 개의 교합점과 3가지 교합력 방향을 가진 27가지 조합의 유한요소 모델을 상정하였다. 금관의 소재는 제 3형 금합금이고, 변연의 형태는 chamfer이다. 합착용 시멘트로는 전 층에서 균일하게 $70{\mu}m$의 두께를 가지는 글라스 아이오노머 시멘트가 사용되었다. 금관에는 100N의 하중을 적용하였다. 협측과 설측 변연의 근접도에 따라서 시멘트층 내 응력은 다른 양상을 나타내었다. 협측은 변연으로부터 약 0.5 mm, 설측은 변연으로부터 약 1 mm 내측에서 최대 응력 값을 가졌다. 하중 방향이 치축에 대해 경사가 클수록, 하중점이 교두첨에 근접해 있을수록 더 큰 응력이 발생하였다.

맞춤형 지대주 제작에 사용되는 수렴 각과 곡률 반경의 값에 따른 가공 정확도 평가 (Evaluation on machining accuracy according to convergence angle and radius of curvature value used for fabricating custom abutments)

  • 홍민호;최성민;권태엽
    • 대한치과재료학회지
    • /
    • 제44권4호
    • /
    • pp.329-336
    • /
    • 2017
  • 본 연구는 맞춤형 지대주 (custom abutment) 설계 시 CAD 프로그램 내에서 선택된 수렴 각 그리고 곡률 반경 값 사용에 따른 가공 정확도를 평가하고자 한다. 치과용 CAD를 기반으로 10개의 맞춤형 지대주를 설계하였다. 제작된 맞춤형 지대주를 정밀 접촉식 스캐너를 이용하여 한 개의 시편을 10회 반복 스캔하였다. 스캔 된 맞춤형 지대주의 데이터는 "Test STL" 파일로 지정하여 저장하였다. Geomagic studio 소프트웨어를 이용하여 각 "Test STL" 파일과 동명 번호로 지정하여 저장된 CAD-reference-model STL 파일 (CRM)과 중첩하였다. 실험 결과에서 A8 군(수렴 각 $8^{\circ}$) 군은 A4 군(수렴 각 $4^{\circ}$) 보다 낮은 오차 수치를 나타났다. 또한, 곡률 반경 값이 높을 수록 맞춤형 지대주의 Top 그리고 chamfer 부위에 오차가 적게 나타냈다(p< 0.05). 전체적으로, 맞춤형 지대주 설계 시 곡률 반경 값은 가공 정확도에 영향을 미치는 것을 알 수 있었다.

제동 시스템에서 고속 저더 개선 평가에 관한 연구 (A Study for High Speed Judder Evaluation on Brake System)

  • 김성환;조성선;이정환
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.485-494
    • /
    • 2013
  • This paper deals with experimental evaluation methods for high speed judder on the brake-caliper system. Firstly, two types of brake caliper systems due to the wheel vibration was evaluated. Secondly, the high-speed judder of the brake was also investigated using the subjective rating evaluation in the high-speed road test. These experimental evaluations were carried out by changing the materials of brake pad and the specifications of the brake-corner module. Based upon the test results, a new specification of the brake pad, $15{\times}5$ vertical chamfer, was proposed. The new brake pad showed 3 points, 60 %, improvement in the subjective-rating evaluation comparing with conventional one. Besides, we need to decide properly with judder characteristic of pad material and have to carefully take into consideration other design parameters; caliper, disc, and the braking performance, durability, squeal noise.

3차원 초음속 터빈의 노즐-로터 상호작용에 관한 수치적 연구 (A Numerical Analysis on the Nozzle-Rotor of a 3-D Supersonic Turbine)

  • 윤원근;신봉근;김귀순;김진한;정은환
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.413-422
    • /
    • 2005
  • 본 연구에서는, 먼저 $Fine^{TM}/Turbo$의 신뢰성을 확보하기 위해 초음속 터빈의 실험 결과와 비교 해석하였다. 그 결과 $Fine^{TM}/Turbo$는 초음속 유동 현상을 비교적 정확하게 해석함을 알 수 있었다. 다음으로 Grid Independency Test를 통하여 3차원 터빈의 적합한 격자계를 선정하여. 3차원 초음속 터빈의 노즐-로터 상호작용에 관해 유동해석을 실시하였다. 터빈의 노즐-로터간의 축방향 간격은 점점 커질수록 높은 추력을 나타냈으며, 로터 블레이드의 Chamfering Angle 또한 Blade-Edge가 날카로워 질수록 추력이 증가하였다.

  • PDF

Influence of Crown Margin Design on the Stress Distribution in Maxillary Canine Restored by All-Ceramic Crown: A Finite Element Analysis

  • Ozer, Zafer;Kurtoglu, Cem;Mamedov, Amirullah M.;Ozbay, Ekmel
    • Journal of Korean Dental Science
    • /
    • 제8권1호
    • /
    • pp.28-35
    • /
    • 2015
  • Purpose: To investigate the influence of crown margin design on the stress distribution and to localize critical sites in maxillary canine under functional loading by using three dimensional finite element analysis. Materials and Methods: The bite force of 100 N, 150 N, and 200 N was applied with an angulation of $45^{\circ}$ to the longitudinal axis of tooth. Six models were restored with IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) with a different margin design. With lingual ledge and various thicknesses, three different core ceramics were designed in each model. Result: In the core ceramic, the maximum tensile stresses were found at the labiocervical region. In the veneering ceramic the maximum tensile stresses were found at the area where the force was applied in all models. Conclusion: Shoulder and chamfer margin types are acceptable for all-ceramic rehabilitations. A ledge on the core ceramic at cervical region may affect the strength of all-ceramic crowns.