• Title/Summary/Keyword: Chamber experiment

Search Result 759, Processing Time 0.032 seconds

DEVELOPMENT OF A METHOD FOR CONTROLLING GAS CONCENTRATION FOR USE IN C.A EXPERIMENTS

  • Yun, H.S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.662-669
    • /
    • 2000
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and low cost system was developed for controlling gas concentration for use in C.A experiments. The gas flow rate through capillary tube had a linear relationship with pressure, $(length)^{-1}$ and $(radius)^4$ of capillary tube, which agreed well with Hagen-Poiseuille's law. The developed system could control the gas concentration in storage chamber within ${\pm}0.3%$ deviation compared to the preset concentration. The required time for producing target gas concentration in storage chamber was exactly predicted by the model used in this study, and it required much longer time than the calculated time which divided the volume of chamber by flow rate. Therefore, for producing target gas concentration as quickly as possible, it needs to supply higher flow rate of gas during the initial stage of experiment when gas concentration in storage chamber has not reached at target value. It appeared that the developed system was very useful for C.A experiments. Because one could decide a desired flow rate by the prediction model, control flow rate freely and easily by changing pressure in the pressure-regulating chamber and the accuracy was high.

  • PDF

Wave Energy Absorption Efficiency of Pneumatic Chamber of OWC Wave Energy Converter (진동수주형 파력발전장치 공기실의 파력에너지 흡수효율)

  • Hong, Key-Yong;Shin, Seung-Ho;Hong, Do-Chun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.173-180
    • /
    • 2007
  • Oscillating wave amplitude in a bottom-mounted OWC chamber designed for wave energy converter is investigated by applying characteristic wave conditions in Korean coastal water. The effects of shape parameters of OWC chamber in a view of wave energy absorbing capability are analyzed. Both experimental and numerical approaches are adopted and their results are compared to optimize the shape parameters which can result in a maximum power production under given wave distribution. The experiment was carried out in a wave flume under 2-D assumption of OWC chamber. The numerical scheme employed a hybrid Green integral equation which adopts the Rankine Green function inside chamber to take account of fluctuating air pressure, while it uses the Kelvin Green function in outer domain. Air duct diameter, chamber width, and submerged depths of front skirt and back wall of chamber changes the magnitude and peak frequency of wave absorption significantly.

  • PDF

An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques (대기중 이산화황 관측 방법들의 실측 비교 연구)

  • 김경렬;이동수;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

Vacuum properties of CFC (carbon fiber composits) (탄소섬유복합재(CFC)의 진공특성)

  • 인상렬;박미영
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.497-506
    • /
    • 1999
  • Carbon has been widely used for the material of plasma facing components in fusion experiment devices like a tokamak, because carbon has good thermal and mechanical properties. However carbon gas a relatively high ougassing rate. Therefore the amount and the surface area of the carbon material used in the vessel will determine the background pressure of the vacuum vessel. In this experiment influences of carbon on the vacuum performance was investigated by measuring chamber pressure, ougassing rater and gas spectrum of carbon fiber composite (CFC) samples in various situations, pumping out, chamber baking, carbon heating (250~$500^{\circ}C$), exposure to atmosphere for maintenance of in-vessel components, etc., occurring routinely during tokamak operations.

  • PDF

Effect of Ignition-Energy Characteristics on the Ignition and the Combustion of a Premixed Gas (점화에너지 특성이 예혼합기의 착화와 연소에 미치는 영향)

  • 이중순;이태원;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 1996
  • In this paper, we study effect of the factors, participating in the combustion as the initial conditions, such as the flow characteristics of the mixture and the initial temperature, pressure and equivalence ratio in the chamber on the ignitability of the mixture, the combustion duration and the maximum combustion-pressure. The experiment was performed in a constant-volume combustion chamber, with turbulent flow inside, equivalent to the actual engine at TDC. The present experiment utilizes three devices which differ from each other in the distribution and the magnitude of discharge energy.

  • PDF

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

An implementation of NDIR type $CO_2$ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics (시간응답특성을 고려한 2광원 1센서 방식의 capnograph 시스템용 NDIR식 $CO_2$ 가스 챔버 설계 및 측정 회로의 구현)

  • Park, I.Y.;Lee, I.K.;Lee, S.K.;Kang, K.M.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.279-285
    • /
    • 2001
  • The capnograph system for determining the partial pressure of carbon dioxide in the blood of a patient was developed based on the NDIR(non-dispersive infrared) absorption technology. NDIR gas analyzing method requires an optical absorption chamber and signal processing hardware. In this paper, we have designed and implemented NDIR type $CO_2$ gas chamber in consideration of the time response characteristics and lamp chopping frequency. And we have implemented signal processing hardware using two infrared sources to reduce the thermal background effect. The implemented gas chamber and signal processing hardware were tested in the temperature variation experiment and human expiratory experiment. The results showed that the system could produce a stable output signal and a good $CO_2$ gas concentration curve like a typical capnogram.

  • PDF

Effect of Transfer Date to a Growth Chamber and Low Temperature on Growth and Flowering of Jeffersonia dubia Benth. (입실시기와 저온처리가 깽깽이풀의 생장과 개화에 미치는 영향)

  • Jeong, Jeong Hag
    • FLOWER RESEARCH JOURNAL
    • /
    • v.17 no.4
    • /
    • pp.266-270
    • /
    • 2009
  • This experiment was conducted to investigate the effect of transfer date to a growth chamber and low temperature on growth and flowering of Jeffersonia dubia for free control of flowering period. According to transfer date, any plant did not sprout when plants were put in a growth chamber from Aug. 20 to Dec. 20. However, all the plants which were put in a growth chamber on Jan. 20 or Feb. 20 sprouted and resulted in flowering. The effect of beginning time and period of low temperature treatment were also observed. At the beginning time of Aug. 20, sprouting and flowering occurred as plant received more than 60 days of low temperature treatment. However, almost of al l the plants sprouted and flowered by only 30 days of low temperature treatment when the low temperature was given after Sep. 20. 60 days of low temperature given again after about three month growing period after dormancy breaking, resulted in resprouting of all plants and 70% of them flowered in this experiment.

A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement (침실 공기질 개선을 위한 강제 환기횟수에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.