• Title/Summary/Keyword: Cervical vertebra

Search Result 114, Processing Time 0.033 seconds

Fractal dimension analysis on CBCT scans for detecting low bone mineral density in postmenopausal women

  • Carvalho, Bruno Fontenele;de Castro, Julia Goncalves Koehne;de Melo, Nilce Santos;Figueiredo, Paulo Tadeu de Souza;Moreira-Mesquita, Carla Ruffeil;de Paula, Ana Patricia;Sindeaux, Rafael;Leite, Andre Ferreira
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.53-60
    • /
    • 2022
  • Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

Development of a Finite Element Human Neck Model for Neck Injury Analysis - Application to Low Speed Rear-End Offset Impacts - (목상해 분석을 위한 상세 유한요소 목모델 개발 - 저속후방 오프셋 충돌에 따른 분석 -)

  • Kim Young Eun;Jo Hui Chang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.913-920
    • /
    • 2005
  • Compared to previous in-vitro test, FE model showed reliable motion patterns. A finite element model of a 50th percentile male neck was developed to study the mechanics of whiplash injury while the rear impacts. The model was consisted of the whole cervical vertebrae including part of occipital, intervertebral discs. which were modeled using linear viscoelastic materials and posterior elements. The sliding interfaces were defined to simulate contact phenomena in facet joints and in odontoid process. All ligaments and atlanto-occipital membrane were modeled as nonlinear bar elements. Only muscle elements were not considered. Motion of each cervical vertebra was obtained from the dynamic simulation with a MADYMO model for 15 km/h $40\%$ rear end offset impacts. Soft tissue neck injury(STNI) was investigated with a developed FE model. In FE model analysis, the high stress was appeared at C3/C4 disc in offset impact. Further research is still needed in order to improve the developed neck FE model for many different crash patterns.

The Formation of Extragraft Bone Bridging after Anterior Cervical Discectomy and Fusion : A Finite Element Analysis

  • Kwon, Shin Won;Kim, Chi Heon;Chung, Chun Kee;Park, Tae Hyun;Woo, Su Heon;Lee, Sung-Jae;Yang, Seung Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.611-619
    • /
    • 2017
  • Objective : In addition to bone bridging inside a cage or graft (intragraft bone bridging, InGBB), extragraft bone bridging (ExGBB) is commonly observed after anterior cervical discectomy and fusion (ACDF) with a stand-alone cage. However, solid bony fusion without the formation of ExGBB might be a desirable condition. We hypothesized that an insufficient contact area for InGBB might be a causative factor for ExGBB. The objective was to determine the minimal area of InGBB by finite element analysis. Methods : A validated 3-dimensional, nonlinear ligamentous cervical segment (C3-7) finite element model was used. This study simulated a single-level ACDF at C5-6 with a cylindroid interbody graft. The variables were the properties of the incorporated interbody graft (cancellous bone [Young's modulus of 100 or 300 MPa] to cortical bone [10000 MPa]) and the contact area between the vertebra and interbody graft (Graft-area, from 10 to $200mm^2$). Interspinous motion between the flexion and extension models of less than 2 mm was considered solid fusion. Results : The minimal Graft-areas for solid fusion were $190mm^2$, $140mm^2$, and $100mm^2$ with graft properties of 100, 300, and 10000 MPa, respectively. The minimal Graft-areas were generally unobtainable with only the formation of InGBB after the use of a commercial stand-alone cage. Conclusion : ExGBB may be formed to compensate for insufficient InGBB. Although various factors may be involved, solid fusion with less formation of ExGBB may be achieved with refinements in biomaterials, such as the use of osteoinductive cage materials; changes in cage design, such as increasing the area of polyetheretherketone or the inside cage area for bone grafts; or surgical techniques, such as the use of plate/screw systems.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • v.25 no.1
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

Acute postoperative myelopathy caused by spontaneous developed cervical disc herniation: Case report & literature review (수술후 자연발생 경추간판탈출에 의한 척수병증: 증례보고 및 문헌고찰)

  • Lee, Jeong-Woo;Lee, Keun Hyeong;Lee, Ju-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.303-308
    • /
    • 2019
  • Non-traumatic acute myelopathy caused by cervical disc herniation is rare. To date, no case has been reported to be caused by extrusion cervical disc herniation, unrelated to patient posture during surgery. Here, we report the case of a 65-year-old male patient with cervical myelopathy who underwent subsequent arthroscopic rotator cuff surgery under general anesthesia; non-cervical spine surgery. Ed. Notes: I am unable to understand the insertion of the highlighted phrase. Please delete if not required, or revise the sentence appropriately. Patient showed acute postoperative tetraplegia in spite of optimal anesthetic management. He showed no limitation of neck movement at pre-operative airway evaluation, and had no history of trauma to the cervical spine. During surgery, there had been no overextension or twisting of the neck, including at the time of anesthetic induction by tracheal intubation. However, cervical disc herniation causing spinal canal cord compression was detected in the postoperative magnetic resonance imaging, which probably resulted in tetraplegia of the patient. Motor and sensory functions were recovered after 21 days of conservative treatment, including steroid pulse intravenous therapy without any surgical intervention. In this report, the disease is described after reviewing other reported cases; furthermore, we also discuss the pathophysiology of the disease. Based on our report, we propose that under general anesthesia, clinicians should pay attention to the possibility of pre-existing cervical disease, even in non-cervical spine surgeries of geriatric patients.

Maturation of cervical vertebrae and Mandibular growth changes (경추골 성숙지표와 하악골 성장)

  • Bae, Jin-Hee;Pank, Hyo-Sang;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.481-492
    • /
    • 1997
  • In order to investigate the possibility of using a cervical vertebral maturation indicator as a mandibular growth indicator, the relationship of cervical vertebral maturation and mandibular & body height growth changes was assessed in biennial serial lateral cephalometric radiographs of eighteen korean male and fourteen korean female while they were 8.5 to 18.5 years old. The following results were obtained. 1. It was a reliable method to evaluate skeletal maturation by using cervical vertebrae. 2. In general, cervical vertebral maturation stages of females were higher than those of males at the same age and there were significant differences in statistics at the age of 10.5, 14.5. 3. The age of a female at the same cervical vertebral maturation stage were earlier than that of a male. 4. In the case of males, significant Ar-Gn increases were found between stage 3 and 4,5; Ar-Go increases between stage 4 and 5. 5. In the case of females, significant S-Gn and Ar-Gn increases were (end between stage 3 and 4. 6. Significant body height increases were found between stage 3 and 4 in both sexes. 7. The peak velocity of body height and mandibular length was observed between cervical vertebral maturation stage 3 and 4 in both sexes. 8. The relationship between mandibular & body height changes and specific maturation stage of cervical vertebra was found, therfore using a cervical vertebral maturation indicator as mandibular growth indicator is quite within realms of possibility.

  • PDF

Clinical Outcome of Modified Cervical Lateral Mass Screw Fixation Technique

  • Kim, Seong-Hwan;Seo, Won-Deog;Kim, Ki-Hong;Yeo, Hyung-Tae;Choi, Gi-Hwan;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.2
    • /
    • pp.114-119
    • /
    • 2012
  • Objective : The purpose of this study was 1) to analyze clinically-executed cervical lateral mass screw fixation by the Kim's technique as suggested in the previous morphometric and cadaveric study and 2) to examine various complications and bicortical purchase that are important for b-one fusion. Methods : A retrospective study was done on the charts, operative records, radiographs, and clinical follow up of thirty-nine patients. One hundred and seventy-eight lateral mass screws were analyzed. The spinal nerve injury, violation of the facet joint, vertebral artery injury, and the bicortical purchases were examined at each lateral mass. Results : All thirty-nine patients received instrumentations with poly axial screws and rod systems, in which one hundred and seventy-eight screws in total. No vertebral artery injury or nerve root injury were observed. Sixteen facet joint violations were observed (9.0%). Bicortical purchases were achieved on one hundred and fifty-six (87.6%). Bone fusion was achieved in all patients. Conclusion : The advantages of the Kim's technique are that it is performed by using given anatomical structures and that the complication rate is as low as those of other known techniques. The Kim's technique can be performed easily and safely without fluoroscopic assistance for the treatment of many cervical diseases.

Comparison of ultrasound-guided stellate ganglion block at 6th and 7th cervical vertebrae using the lateral paracarotid out-of-plane approach for sympathetic blockade in the upper extremity

  • Baek, Jongyoon;Kim, Bum Soo;Yu, Hwarim;Kim, Hyuckgoo;Lim, Chaeseok;Song, Sun Ok
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.199-204
    • /
    • 2018
  • Background: The authors have performed ultrasound-guided stellate ganglion block (SGB) in our clinic using a lateral paracarotid approach at the level of the 6th cervical vertebra (C6). Although SGB at C6 is a convenient and safe method, there are ongoing concerns about the weak effect of sympathetic blockade in the ipsilateral upper extremity. Therefore, ultrasound-guided SGB was attempted using a lateral paracarotid approach at the level of the 7th cervical vertebra (C7). This prospective study aimed to compare changes in skin temperature after SGB was performed at C6 and C7, and to introduce a lateral paracarotid approach for SGB. Methods: Thirty patients underwent SGB twice: once at C6 and once at C7. For every SGB, the skin temperature of the patient's hypothenar area was measured for 15 min at 1-min intervals. Skin temperatures before and after SGB and side effects were compared between C6 and C7 groups. Results: The temperature of the upper extremity increased after SGB was performed at C6 and C7. There were significant differences between mean pre-SGB and the largest increases in post-SGB temperatures ($0.50{\pm}0.38^{\circ}C$ and $1.41{\pm}0.68^{\circ}C$ at C6 and C7, respectively; p<0.05). Significantly increased post-SGB temperatures (difference > $1^{\circ}C$) were found in 5/30 (16.7%) and 24/30 (80%) cases for C6 and C7, respectively (p<0.05). There were no significant differences in side effects between SGB performed at C6 or C7 (p>0.05). Conclusion: The lateral paracarotid approach using out-of-plane needle insertion for ultrasound-guided SGB performed at C7 was feasible and more effective at elevating skin temperature in the upper extremity than SGB at C6.

Tracheal Collapse in a Calf (송아지에 발생한 기관허탈)

  • 이채용;김상기;강문일;정순욱;이정길
    • Journal of Veterinary Clinics
    • /
    • v.15 no.1
    • /
    • pp.188-192
    • /
    • 1998
  • A 3-month old female Holstein calf was presented with about a month history of intermittent dyspnea, exercise intolerance and cough despite antibiotic therapy. Auscultation revealed prominent inspiratory and exploratory crackles and wheezes over the causal cervical trachea which were heard equally over both side of the chest.4 modest amount of forced exercise caused severe respiratory distress with stertorous noise and occasional honkinglike cough. Pasteurella spp. was isolated on the nasal swabs and a hemogram showed mild leucocytosis with a mature neutrophilia and mild monocytosis. Lateral radiographs of the neck and thorax revealed a marked narrowing of the tracheal lumen extending from the level of the fifth cervical to the second thoracic vertebra, and the lung field was judged to be within normal limitsi except very mild peribronchial thickening. The hypertrophic non-union fractures of the first pair of ribs were noted with a well delineatedr redundant callus formations and also the completely healed fractures were found on the next seven pairs of ribs. A diagnosis of tracheal collapse was made, which is thought to be a traumatic origin.4 poor prognosis was given. The calf was euthanatized and necropsied. The tracheal rings from 19th to 41s1 were collapsed dorsoventrally. Histologically, there was no difference between the collapsed and normal areas of the tracheae except the folding mucosal layer in the collapsed area. This report details a case of tracheal collapse in a calli and the literature is reviewed.

  • PDF

A Comparison for Cervical Neural Foraminal Area by 3-dimensional CT in Normal Adults (3차원 컴퓨터단층촬영상을 이용한 정상 성인의 경추 신경공 면적 비교)

  • Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.623-627
    • /
    • 2021
  • Cervical foraminal stenosis is a disease in which the nerves that pass from the spinal canal to the limbs are narrowed and the nerves are compressed or damaged. Due to the lack of an imaging method that provides quantitatively stenosis, this study attempted to evaluate the area of the cervical vertebrae by reconstructing a three-dimensional computed tomography image, and to determine the area of the neural foramen in normal adults to calculate the stenosis rate. Using a three-dimensional image processing program, the surrounding bones including the posterior spinous process, lateral process, and lamellar bones of the cervical vertebra were removed so that the neural foramen could be observed well. A region of interest including the neural foraminal area of the three-dimensional image was set using ImageJ, and the number of pixels in the neural foraminal area was measured. The neural foraminal area was calculated by multiplying the number of measured pixels by the pixel size. To measure the largest neural foraminal area, it was measured between 40~50 degrees in the opposite direction and 15~20 degrees toward the head. The average area of the right C2-3 foramen was 44.32 mm2, C3-4 area was 34.69 mm2, C4-5 area was 36.41 mm2, C5-6 area was 35.22 mm2, C6-7 area was 36.03 mm2. The average area of the left C2-3 foramen was 42.71 mm2, C3-4 area was 32.23 mm2, C5-6 area was 34.56 mm2, and C6-7 area was 31.89 mm2. By creating a reference table based on the neural foramen area of normal adults, the stenosis rate of patients with neural foraminal stenosis could be quantitatively calculated. It is expected that this method can be used as basic data for the diagnosis of cervical vertebral foraminal stenosis.