• 제목/요약/키워드: Cervical plate system

검색결과 14건 처리시간 0.026초

유한요소법을 이용한 척추 삽입형 경추판 시스템에 대한 생체역학적 피로해석 (Biomechanical Fatigue Analysis of Cervical Plate Systems by using a Computer Simulation Based on Finite Element Method)

  • 김성민;양인철;조성윤
    • 한국정밀공학회지
    • /
    • 제25권8호
    • /
    • pp.96-103
    • /
    • 2008
  • In this study, we performed the biomechanical analysis of cervical plate systems by using a computer simulation based on finite element method to derive reliable model by analysis of design variables and fatigue behavior. To simulate the cervical spine movement in-vivo state by surgery, we modeled the cervical plate system which consisted of screws, rings, rivets, and plate and Ultra High Molecular Weight Polyethylene (UHMWPE) Block. The experiment of cervical plate system followed the ASTM F1717 standards that covered the materials and methods for the static and fatigue testing. The result of computer simulation is compared with experimented test. We expected this study is to derive reliable results by analysis of design variables and fatigue behavior for developing a new model.

경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향 (Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation)

  • 김근수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

퇴행성 경추질환에서 전방경유 추간판 절제술 및 골유합술의 결과분석 (Analysis of Noninstrumented Anterior Cervical Discectomy and Interbody Fusion in Degenerative Cervical Disease)

  • 이상원;송근성
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.180-185
    • /
    • 2001
  • Objectives : We retrospectively studied the efficacy of anterior cervical discectomy and interbody fusion without plate fixation in degenerative cervical disease. Methods : Thirty two consecutive patients with degenerative cervical disease treated by decompression and interbody fusion(Smith-Robinson technique) without anterior cervical plating were studied for postoperative complication rate as well as the clinical and radiologic outcomes and were compared the result of ours with other reported series where the anterior cervical plating was used. Results : All cases were reviewed after average period of 13 months for the purpose of this study. There were 4 postoperative complications related to grafting. A solid fusion was obtained in all cases with single-level fusion(n=21) and 81.8 % of the cases with a two-level fusion(n=11). The overall fusion rate was 93.8 % and fusion rate per level fused was 95.3%. The clinical outcome of the patients was comparable with that in the literature, with one patient having a poor result. Comparing the result of this study with others of the anterior cervical plating, clinical outcome and fusion rate were not superior in plate fixation group in single-level fusion, but increased fusion rate and decreased graft-related complication rate were noted in multilevel fusion with plate fixation. However, the clinical outcome was not superior to noninstrumented fusion group of this study. Conclusion : These results demonstrate that anterior cervical discectomy and interbody fusion(Smith-Robinson technique) without instrumentation is safe and reliable method of single-level fusion in degenerative cervical disease. Plate fixation system doesn't seem necessary in single level fusion in degenerative cervical disease.

  • PDF

Anterior Cervical Discectomy and Fusion Using a Double Cylindrical Cage versus an Anterior Cervical Plating System with Iliac Crest Autografts for the Treatment of Cervical Degenerative Disc Disease

  • Kim, Seong Joon;Kim, Sang Don
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권1호
    • /
    • pp.12-17
    • /
    • 2014
  • Objective : Anterior cervical discectomy and fusion (ACDF) is often complicated by subsidence, pseudoarthrosis, kyphosis, and graft donor site morbidities. To decrease the occurrence of these complications, various types of cages have been developed. We designed this retrospective study to analyze and compare the efficacy and outcomes of ACDF using double cylindrical cages (DCC) (BK Medical, Seoul, Korea) versus an anterior cervical plating system with autogenous iliac crest grafts. Methods : Forty-eight patients were treated with autograft and plating (plate group), and 48 with DCC group from October 2007 to October 2011. We analyzed construct length, cervical lordotic curvarture, the thickness of the prevertebral soft tissue, segmental instability, and clinical outcomes. Results : There were no significant differences between the two groups with regard to the decrease in construct length or cervical lodortic curvature at the 3-, 6-, and 12-month follow-ups. The prevertebral soft tissue was thinner in the DCC group than the plate group immediately after surgery and at the 3-, 6-, and 12-month follow-ups. The difference in interspinous distance on flexion-extension was shorter in the plate group than the DCC group at the 3- and 6-month follow-ups. However, there was no significant difference in this distance between the two groups at the 12-month follow-up. Conclusion : A double cylindrical cage is a good alternative for fusion in patients with cervical degenerative diseases; the surgical method is relatively simple, allows good synostosis, has less associated prevertebral soft tissue swelling, and complications associated with autografting can be avoided.

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권4호
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Clinical and Radiological Outcomes of Anterior Cervical Interbody Fusion Using Hydroxyapatite Spacer

  • Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.300-304
    • /
    • 2009
  • Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.

The Management of Bilateral Interfacetal Dislocation with Anterior Fixation in Cervical Spine : Comparison with Combined Antero-Posterior Fixation

  • Kim, Ki-Hong;Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.305-310
    • /
    • 2007
  • Objective : Combined antero-posterior fixation has been a standard method for bilateral interfacetal dislocation in cervical spine. The purpose of this study is to evaluate the efficacy and complication of anterior cervical stabilization in treatment of bilateral interfacetal dislocation. Methods : A total of 65 cases of traumatic bilateral interfacetal dislocation in cervical spine who were managed in our institution, from Mar. 1997 to Feb. 2006, were included in this study. Closed reduction was tried in all cases before operation. If closed reduction was accomplished successfully, only anterior cervical fixation was performed (Group I), and attempted to place screws bicortically as possible with unicortical screws. If failed, posterior open reduction with fixation was first tried, followed by anterior cervical fixation (Group II). All patients were evaluated for neurological outcome and radiological evidence of healing. Results : The Group I included 47 patients and the Group II, 18 patients. The improvement of Frankel grade and increase of mean cervical lordosis angles were not statistically different between two groups. Screw-plate system used did not influence the outcome. On follow up, solid bone fusion was evident and there were no cases of instability in both groups. Conclusion : Our study demonstrated that anterior cervical fixation on BID is safe and effective in comparison with combined antero-posterior cervical fixation.

A Biomechanical Comparison among Three Surgical Methods in Bilateral Subaxial Cervical Facet Dislocation

  • Byun, Jae-Sung;Kim, Sung-Min;Choi, Sun-Kil;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권2호
    • /
    • pp.89-95
    • /
    • 2005
  • Objective: The biomechanical stabilities between the anterior plate fixation after anterior discectomy and fusion (ACDFP) and the posterior transpedicular fixation after ACDF(ACDFTP) have not been compared using human cadaver in bilateral cervical facet dislocation. The purpose of this study is to compare the stability of ACDFP, a posterior wiring procedure after ACDFP(ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation. Methods: Ten human spines (C3-T1) were tested in the following sequence: the intact state, after ACDFP(Group 1), ACDFPW(Group 2), and ACDFTP(Group 3). Intervertebral motions were measured by a video-based motion capture system. The range of motion(ROM) and neutral zone(NZ) were compared for each loading mode to a maximum of 2.0Nm. Results: ROMs for Group 1 were below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation without significances. Group 2 produced additional stability in axial rotation of ROM and in flexion of NZ than Group 1 with significance. Group 3 provided better stability than Group 1 in bending and axial rotation, and better stability than Group 2 in bending of both ROM and NZ. There was no significant difference in extension modes for the three Groups. Conclusion: ACDFTP(Group 3) demonstrates the most effective stabilization followed by ACDFPW(Group 2), and ACDFP(Group 1). ACDFP provides sufficient strength in most loading modes, ACDFP can provide an effective stabilization for bilateral cervical facet dislocation with a brace.

PCB 기구와 이종골을 이용한 경추체간 전방 유합술 (PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion)

  • 박정현;오성훈;이형중;김주헌;김영수;고용;김광명;오석전
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권11호
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF