• Title/Summary/Keyword: Cervical plate

Search Result 72, Processing Time 0.032 seconds

Outcome Analysis of the Patients with and without Anterior Plating in Multi-Level Degenerative Cervical Diseases (다분절 퇴행성 경추질환에서의 전방 금속판 사용 유무에 따른 환자의 예후분석)

  • Kim, Sang Woo;Kim, Sung Min;Shin, Dong Ik;Cho, Yong Jun;Shim, Young Bo;Choi, Sun Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1369-1374
    • /
    • 2001
  • Objectives : The rates of pseudarthrosis for two- and three level fusion have been reported to be 17-63 and 50% without anterior cervical plating. The purpose of this study is to assess the effects of anterior cervical plating in the treatment of multilevel degenerative cervical disease such mostly the additional risks associated with hardware implants and its benefits, fusion rate and radiographic results, and clinical outcomes. Methods : Forty-seven patients who underwent operations between 1993 and 1997 were retrospectively reviewed. The technique for operation was same for both groups(Smith Robinson with autologous iliac bone graft). Group I consisted of 35 consecutive patients treated with anterior cervical decompression and fusion with anterior cervical plate fixation. Group II consisted of 12 consecutive patients treated without plate fixation. We compared clinical outcomes by Prolo score, radiographic results in the rate of fusion, cervical lordosis by Gore angle, disc height by Farfan method, and surgical complications between two groups. Results : The favorable clinical outcomes(excellent and good) by Prolo score were observed with the use of anterior cervical plate fixation(89% vs 75%). The successful fusion rate of multilevel cervical fusion was as seen with anterior cervical plate fixation(97% vs 75%). The overall graft complication rate in multilevel fusions was decreased, with anterior cervical plate fixation, and the hardware related complications were relatively minimal without serious consequences. Conclusion : Anterior cervical plate fixation in the treatment of multilevel cervical disorders is an effective stabilizing method which provides increased bony fusion rate, decreased graft complications, maintained cervical lordosis, early mobilization of the these patients without serious hardware related complications.

  • PDF

New Technical Tip for Anterior Cervical Plating : Make Hole First and Choose the Proper Plate Size Later

  • Park, Jeong-Yoon;Zhang, Ho-Yeol;Oh, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.212-216
    • /
    • 2011
  • Objective : It is well known that plate-to-disc distance (POD) is closely related to adjacent-level ossification following anterior cervical plate placement. The study was undertaken to compare the outcomes of two different anterior cervical plating methods for degenerative cervical condition. Specifically, the new method involves making holes for plate screws first with an air drill and then choosing a plate size. The other method was standard, that is, decide on the plate size first, locate the plate on the anterior vertebral body, and then drilling the screw holes. Our hypothesis was that the new technical tip may increase POD as compared with the standard anterior cervical plating procedure. Methods : We retrospectively reviewed 49 patients who had a solid fusion after anterior cervical arthrodesis with a plate for the treatment of cervical disc degeneration. Twenty-three patients underwent the new anterior cervical plating technique (Group A) and 26 patients underwent the standard technique (Group B). POD and ratios between POD to anterior body heights (ABH) were measured using postoperative lateral radiographs. In addition, operating times and clinical results were reviewed in all cases. Results : The mean durations of follow-up were $16.42{\pm}5.99$ (Group A) and $19.83{\pm}6.71$ (Group B) months, range 12 to 35 months. Of these parameters mentioned above, cephalad POD (5.43 versus 3.46 mm, p=0.005) and cephalad POD/ABH (0.36 versus 0.23, p=0.004) were significantly greater in the Group A, whereas operation time for two segment arthrodesis (141.9 versus 170.6 minutes, p=0.047) was significantly lower in the Group A. There were no significant difference between the two groups in caudal POD (5.92 versus 5.06 mm), caudal POO/ABH (0.37 versus 0.32) and clinical results. Conclusion : The new anterior cervical plating method represents an improvement over the standard method in terms of cephalad plate-to-disc distance and operating time.

Biomechanical Fatigue Analysis of Cervical Plate Systems by using a Computer Simulation Based on Finite Element Method (유한요소법을 이용한 척추 삽입형 경추판 시스템에 대한 생체역학적 피로해석)

  • Kim, Sung-Min;Yang, In-Chul;Cho, Sung-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.96-103
    • /
    • 2008
  • In this study, we performed the biomechanical analysis of cervical plate systems by using a computer simulation based on finite element method to derive reliable model by analysis of design variables and fatigue behavior. To simulate the cervical spine movement in-vivo state by surgery, we modeled the cervical plate system which consisted of screws, rings, rivets, and plate and Ultra High Molecular Weight Polyethylene (UHMWPE) Block. The experiment of cervical plate system followed the ASTM F1717 standards that covered the materials and methods for the static and fatigue testing. The result of computer simulation is compared with experimented test. We expected this study is to derive reliable results by analysis of design variables and fatigue behavior for developing a new model.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Analysis of Noninstrumented Anterior Cervical Discectomy and Interbody Fusion in Degenerative Cervical Disease (퇴행성 경추질환에서 전방경유 추간판 절제술 및 골유합술의 결과분석)

  • Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.180-185
    • /
    • 2001
  • Objectives : We retrospectively studied the efficacy of anterior cervical discectomy and interbody fusion without plate fixation in degenerative cervical disease. Methods : Thirty two consecutive patients with degenerative cervical disease treated by decompression and interbody fusion(Smith-Robinson technique) without anterior cervical plating were studied for postoperative complication rate as well as the clinical and radiologic outcomes and were compared the result of ours with other reported series where the anterior cervical plating was used. Results : All cases were reviewed after average period of 13 months for the purpose of this study. There were 4 postoperative complications related to grafting. A solid fusion was obtained in all cases with single-level fusion(n=21) and 81.8 % of the cases with a two-level fusion(n=11). The overall fusion rate was 93.8 % and fusion rate per level fused was 95.3%. The clinical outcome of the patients was comparable with that in the literature, with one patient having a poor result. Comparing the result of this study with others of the anterior cervical plating, clinical outcome and fusion rate were not superior in plate fixation group in single-level fusion, but increased fusion rate and decreased graft-related complication rate were noted in multilevel fusion with plate fixation. However, the clinical outcome was not superior to noninstrumented fusion group of this study. Conclusion : These results demonstrate that anterior cervical discectomy and interbody fusion(Smith-Robinson technique) without instrumentation is safe and reliable method of single-level fusion in degenerative cervical disease. Plate fixation system doesn't seem necessary in single level fusion in degenerative cervical disease.

  • PDF

Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases : Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation

  • Kim, Min-Ki;Kim, Sung-Min;Jeon, Kwang-Mo;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.135-140
    • /
    • 2012
  • Objective : To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods: The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results: Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion: ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH.

Comparison of Fusion with Cage Alone and Plate Instrumentation in Two-Level Cervical Degenerative Disease

  • Joo, Yong-Hun;Lee, Jong-Won;Kwon, Ki-Young;Rhee, Jong-Joo;Lee, Hyun-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.342-346
    • /
    • 2010
  • Objective : This study assessed the efficacy of anterior cervical discectomy and fusion (ACDF) with cage alone compared with ACDF with plate instrumentation for radiologic and clinical outcomes in two-level cervical degenerative disease. Methods : Patients with cervical degenerative disc disease from September 2004 to December 2009 were assessed retrospectively. A total of 42 patients received all ACDF at two-level cervical lesion. Twenty-two patients who underwent ACDF with cage alone were compared with 20 patients who underwent ACDF with plate fixation in consideration of radiologic and clinical outcomes. Clinical outcomes were assessed using Robinson's criteria and posterior neck pain, arm pain described by a 10 point-visual analog scale. Fusion rate, subsidence, kyphotic angle, instrument failure and the degenerative changes in adjacent segments were examined during each follow-up examination. Results : VAS was checked during each follow-up and Robinson's criteria were compared in both groups. Both groups showed no significant difference. Fusion rates were 90.9% (20/22) in ACDF with the cage alone group, 95% (19/20) in ACDF with the plate fixation group (p = 0.966). Subsidence rates of ACDF with cage alone were 31.81% (7/22) and ACDF with plate fixation were 30% (6/20) (p = 0.928). Local and regional kyphotic angle difference showed no significant difference. At the final follow-up, adjacent level disease developed in 4.54% (1/22) of ACDF with cage alone and 10% (2/20) of ACDF with plate fixation (p= 0.654). Conclusion : In two-level ACDF, ACDF with cage alone would be comparable with ACDF with plate fixation with regard to clinical outcome and radiologic result with no significant difference. We suggest that the routine use of plate and screw in 2-level surgery may not be beneficial.

A Prospective Study with Cage-Only or Cage-with-Plate Fixation in Anterior Cervical Discectomy and Interbody Fusion of One and Two Levels

  • Kim, Sam Yeol;Yoon, Seung Hwan;Kim, Dokeun;Oh, Chang Hyun;Oh, Seyang
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.691-700
    • /
    • 2017
  • Objective : The authors prospectively analyzed the effect of one-level or two-level anterior cervical discectomy and fusion (ACDF), comparing stand-alone cages and cage-with-plate fixation constructs with respect to clinical outcomes and radiologic changes. Methods : A total of 84 patients who underwent one-level (n=52) or two-level ACDF (n=32) for cervical disc disease and who completed 2 years of follow-up were included in this study. The patients were divided by cervical level and grouped into ACDF-Cage-only and ACDF-Cage-with-plate groups. The following parameters were assessed using radiographs : subsidence, C2-C7 lordosis angle, fusion segment angle, adjacent disc space narrowing, and fusion status. Clinical outcomes were assessed using the neck disability index (NDI) and visual analog scale scores for arm pain. Results : In the comparison of one-level ACDF-cage-only and ACDF-cage-with-plate groups, the NDI score was better in the cage-only group at the 3-, 12-, and 24-month follow-ups : however, no significant difference in clinical outcomes was observed. In the comparison of two-level ACDF-cage-only and ACDF-cage-with-plate groups, no difference in any clinical outcome was observed between the two groups. At the 24-month follow-up, subsidence was observed in 45.8% of patients in the one-level cage-only group and 32.1% of patients in the one-level cage-with-plate fixation group. There was no statistically significant difference in the incidence rate between the two groups (p=0.312). Subsidence in the two-level cage-only group (66.6%) was significantly more frequent than in the two-level cage-with-plate fixation group (30%; p=0.049). The fusion rate for patients in the one-level cage-only group was not significantly different from that in the one-level cage-with-plate fixation group (cage-only, 87.5%; cage-with-plate fixation, 92.9%; p=0.425) ; fusion rate in the two-level patients were also similar between groups (cage-only, 83.3%; cage-with-plate fixation, 95%; p=0.31). Conclusion : Our clinical results showed that for single-level cases, plate fixation had no additional benefit versus cage-only; for two-level ACDF cases, the fusion rate and clinical outcomes were similar, although the cage-with-plate fixation group had a lower incidence of cage subsidence than did the cage-only group. We conclude that physicians should be aware of this possible disadvantage associated with using cervical plates in one-level ACDF. However, in two-level ACDF, subsidence is more likely to occur without plate fixation, and thus the addition of plate fixation should be considered.

Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion

  • Cho, Pyung Goo;Ji, Gyu Yeul;Park, Sang Hyuk;Shin, Dong Ah
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1092-1099
    • /
    • 2018
  • Study Design: In-vitro biomechanical investigation. Purpose: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent levels. Overview of Literature: Biodegradable implants have been recently introduced for cervical spine surgery. However, their effectiveness and safety remains unclear. Methods: A linear three-dimensional finite element (FE) model of the lower cervical spine, comprising the C4-C6 vertebrae was developed using computed tomography images of a 46-year-old woman. The model was validated by comparison with previous reports. Four models of ACDF were analyzed and compared: (1) a titanium plate and bone block (Tita), (2) strong biodegradable plate and bone block (PLA-4G) that represents the early state of the biodegradable plate with full strength, (3) weak biodegradable plate and bone block (PLA-1G) that represents the late state of the biodegradable plate with decreased strength, and (4) stand-alone bone block (Bloc). FE analysis was performed to investigate the relative motion and intervertebral disc stress at the surgical (C5-C6 segment) and adjacent (C4-C5 segment) levels. Results: The Tita and PLA-4G models were superior to the other models in terms of higher segment stiffness, smaller relative motion, and lower bone stress at the surgical level. However, the maximal von Mises stress at the intervertebral disc at the adjacent level was significantly higher in the Tita and PLA-4G models than in the other models. The relative motion at the adjacent level was significantly lower in the PLA-1G and Bloc models than in the other models. Conclusions: The use of biodegradable plates will enhance spinal fusion in the initial stronger period and prevent adjacent segment degeneration in the later, weaker period.

Clinical and Computed Tomography Evaluation of Plate and Screw on the Cervical Lateral Mass : A Modified Magerl's Technique

  • Lee, Dong-Chan;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Jong-Oon;Hyun, Dong-Keun;Park, Heon-Seon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.251-255
    • /
    • 2006
  • Objective : To determine the clinical and radiological safety of 15 consecutive patients managed with plate and screw fixation systems applied to the cervical lateral mass. Methods : 15 patients who underwent posterior cervical and T1 arthrodesis were reviewed from Jan 2002 to Dec 2004. Posterior cervical screw and plate fixation was applied on the lateral mass of the cervical spine. The authors have tried lateral mass screw fixation using a modified Magerl's technique [$20^{\circ}$ lateral and $20{\sim}30^{\circ}$ rostral screw trajectory] under preliminary radiological study. The average patient age was $39.73^{\circ}{\pm}11.00\;years$, and the average follow-up period was $9.73^{\circ}{\pm}6.77\;months$. Computed tomography scans taken after surgery were reviewed to confirm the attempted screw trajectory correct and safety. Results : Three of 93 lateral mass screws were malpositioned but clinical damage was not noted. Two of 8 pedicle screws on the T1 vertebrae were not placed on the correct pedicle area. Screw and plate loosening was observed in one case but was not subjected to an additional procedure because of maintained screw position observed during follow-up periods. Conclusion : The results of this study indicate that lateral mass screw fixation using the Modified Magerl's technique on the cervical lateral mass may provide safe and effective application on the patients. In addition, the chance of incorrectly placed screws was higher in T1 pedicle screw fixation than in lateral mass screw fixation of the cervical area.