• Title/Summary/Keyword: Certification grade

Search Result 85, Processing Time 0.021 seconds

An Comparative Analysis of Certification Results for Pre-Certified Office Buildings according to G-SEED Revisions (녹색건축 인증제도 업무용 건축물 개정 전·후 인증결과 비교분석)

  • Yun, Yo-Sun;Chae, Chang-U;Kim, Yu-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.51-58
    • /
    • 2018
  • G-SEED has been introduced with the aim of reducing energy use and resources since 2002, as the system of certificating environmental friendliness of buildings to create comfortable environment. This study analyzed the changes of certification standard of G-SEED since the revision in 2016, comparing certification results of office buildings by grade, category and certification items between G-SEED 2013-2 version and revised version of 2016. Also, this study analyzed the average points and their standard deviation of certification items including both deleted items and newly added items and extracted items needed to be reviewed in the future revision. In the revision, G-SEED has been extended its certification system to involve existing buildings and Innovative Design categories newly introduced with revising the certification items and difficulties. In revised version of G-SEED, the certification grade appeared to change its acquisition ratio decreasing Green2 and increasing Green4, during Green1 and Green3 were similar in proportion. The average scores by categories appeared decrease in Energy and Environmental Pollution category and Materials and Resources category, on the other hand, Maintenance category appeared the highest increase in the average score. Otherwise, Land Use and Transportation, Water Circulation, Ecology, Indoor Environment categories appeared similar average scores both version of G-SEED. In addition, the Innovative Design which was newly introduced category, seems to expect gradual gaining high scores according to technology development in future, although its possession has shown lower scores in revised version.

A study on the biographical records and meritorious certification awarded to Jeong In-Kyung in Koryo Dynasty (고려 후기 정인경의 정책과 공신록권의 분석)

  • 여은영;남권희
    • Journal of Korean Library and Information Science Society
    • /
    • v.21
    • /
    • pp.485-528
    • /
    • 1994
  • The aim of this study is to analyze biographical records and Meritorious Certification of Jeong In-Kyung. The analysis is made in the respects of : 1) Bibliographical analysis of the (SeoSan Jeongshi GaSeung) 2) Biographical study of Jeong In-Kyung 3) Historical and Political background in the period of king ChungYeul The summary of this study is as follows: 1. The

  • PDF

Factors influencing performance confidence in paramedic students by knowledge and experience of respiratory-assistant therapy (응급구조학과 학생들의 호흡보조요법 경험, 지식이 수행자신감에 미치는 영향요인)

  • Uhm, Dong-Choon;Kim, A-Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.2
    • /
    • pp.67-77
    • /
    • 2018
  • Purpose: This study was conducted to identify the factors influencing performance confidence by knowledge and experience of respiratory-assistant therapy in paramedic students. Methods: A descriptive survey study used a convenience sample comprising 387 students from September 15 to October 31, 2016. Data were analyzed using descriptive statistics, t-test, ANOVA, Pearson's correlation coefficient, and regression analysis. Results: Knowledge was statistically significant by college(3-year), acquired certification, and observation experience in respiratory-assistant therapy. Performance confidence was statistically significant by sex, academic grade($3.0{\leq}$), acquired certification, and observation and performance experience in respiratory-assistant therapy. There was a significant correlation between knowledge and acquired certification, clinical practice, and major satisfaction. There was a significant correlation between performance confidence and acquired certification, clinical practice, major satisfaction, and knowledge. Regression analysis revealed that performance confidence accounted for 22.9% of the variance by academic grade(3.0~3.99), acquired certification, and major satisfaction. Conclusion: For paramedic students in clinical practice and in-school classes, it is important to improve performance confidence by combining training instruction with experience and education of respiratory-assistant therapy.

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building (지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향)

  • Geon Ho Moon;Chang Yong Park
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.

A Study on Implementation Plan of Clean Hydrogen Certification System (청정수소 인증제 시행방안 연구)

  • RHEE, HAN WOO;KIM, JIN HO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.301-308
    • /
    • 2022
  • The Hydrogen Economy Promotion and Hydrogen Safety Management Act (hereinafter referred to as the "Hydrogen Economy Act") stipulates matters related to certification and cancellation of clean hydrogen by grade, and requires those who produce, import, or sell clean hydrogen to report to the Minister of Trade, Industry and Energy. In order for this system to operate smoothly, the clean hydrogen Certification system must be designed to meet international standards, and the institution operating the System must have appropriate capabilities and foundations. The clean hydrogen certification system should serve as an opportunity for Korea's domestic energy industry to take a leap forward.

Design and Characteristics Analysis of the 78 kWe Grade Synchronous Generator for Disused Diesel Engines

  • Youn, Jun-Seop;Kim, Hae-Joong;Kim, Youn-Hwan;Moon, Jae-Won
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.122-132
    • /
    • 2017
  • This study dealt with the design process of the 78 kW permanent magnet synchronous generator for engines. After the calculation of the basic dimensions through a theoretical method in the process of initial model design, FEA (finite-element analysis) and a d,q-axis equivalent circuit were used to identify the generator characteristics depending on the number of poles. With the use of the space harmonic analysis method, the back-EMF (electromotive force) and THD were checked, and then the number of slots was determined. In addition, the most optimized generator dimensions were determined through a sizing optimization technique. Based on this, the optimum model with enhanced efficiency, material costs, and temperature characteristics was derived, and the availability of the design method was confirmed through a comparative analysis of the initial and optimum models.

A Study on the Comparison for Energy Consumption Characteristics between G-SEED certified and non-certified Office Buildings in Korea (G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량 특성에 관한 연구 : 업무시설을 대상으로)

  • Kim, Jong-Hyun;Kim, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.33-43
    • /
    • 2019
  • Considerable efforts have been made to reduce greenhouse gas emission around the world to cope with climate change. The government is implementing G-SEED certification to promote energy efficient building design. This study aims to verify the effectiveness of the G-SEED certification system by analyzing the actual energy use of certified and non-certified office buildings. For this purpose, the energy consumption of 135 certified and 142 non-certified office buildings was analyzed according to the seasonal characteristics, building size and number of floors, approval year, and certification grade. The energy saving effects of certified buildings was about 50% higher than that of non-certified buildings. The seasonal energy consumption of buildings is closely related to the heating degree-days. The energy consumption of certified and non-certified buildings decreases with increasing approval year. On the other hand, the energy consumption according to building size and certification grade is not related. This study provides meaningful basic data of G-SEED certification system for future improvement. As the building energy performance standards are strengthened over the years, it is necessary to make the individual score of G-SEED certified projects open to the public to configure the factors of energy efficiency.

The Effect of Eco-friendly Characteristics on the Price of Office Buildings (친환경 특성이 오피스 빌딩 가격에 미치는 영향)

  • So, Soung Kue;Cho, Joo Hyun
    • Korea Real Estate Review
    • /
    • v.28 no.2
    • /
    • pp.49-64
    • /
    • 2018
  • The purpose of this study is to analyze the effect of eco-friendly building certification grade on the price and cost of office in Seoul office building. For this purpose, multiple regression analysis is used to examine the prices of buildings. In order to identify the effect of environmental cost reduction of buildings with high eco-friendly certification, we also performed LCC (Life Cycle Cost) + LCA (Life Cycle Assessment) analysis. Results of our analysis show that office buildings with a higher level of eco-friendly certification are priced significantly higher. Through LCC analysis, it was also found that buildings with high levels of eco-friendly certification cost less than those with lower-level certification. Furthermore, it was confirmed that office buildings with higher-level environmental certification have total lower environmental load costs (TCA = LCC+LCA) than buildings without certification. According to the TCA analysis, buildings with a high level eco-certification generated lower social costs than buildings with lower-level or no certification.

A Study on the Estimation of Additional Cost for the Certification of Zero Energy Apartment Buildings (공동주택 제로에너지빌딩 인증을 위한 적정가산비 산정에 관한 연구)

  • Sa, Yong-gi;Haan, Chan Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.21-30
    • /
    • 2019
  • Environmental and energy issues such as abnormal climate and depletion of fossil fuel due to global warming have emerged as a critical task to threaten human survival. As a result, interest in the Zero Energy Building is increasing as it is an innovative building that can significantly contribute to building energy reduction and greenhouse gas reduction. In the market, however, the added cost of construction is a major stumbling block to the revitalization of the Zero Energy certification. In this study, general private apartment complexes were selected for research, detailed elements for Zero Energy certification were presented based on the construction criteria for eco-friendly houses from the initial design stage, and the cost efficiency analysis of the components for certification were presented. It has been analyzed that only Grade 3 certification can be implemented in apartments due to technical level and physical limitations. Also, after reviewing the cost trend during the lifecycle cost, all expenses can be recovered within 13 years after completion only in the case of grade 5 of the Zero Energy Building. The additional costs proposed in the present study are reflected appropriately in the review of projects for apartments scheduled for order in the future to contribute to the revitalization of the Zero Energy Building certification.