• 제목/요약/키워드: Cerebral angiography

검색결과 291건 처리시간 0.021초

Morphological and Hemodynamic Parameters for Middle Cerebral Artery Bifurcation Aneurysm Rupture Risk Assessment

  • Qin, Hao;Yang, Qixia;Zhuang, Qiang;Long, Jianwu;Yang, Fan;Zhang, Hongqi
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.504-510
    • /
    • 2017
  • Objective : To investigate the morphological and hemodynamic parameters associated with middle cerebral artery (MCA) bifurcation aneurysm rupture. Methods : A retrospective study of 67 consecutive patients was carried out based on 3D digital subtraction angiography data. Morphological and hemodynamic parameters including aneurysm size parameters (dome width, height, and perpendicular height), longest dimension from the aneurysm neck to the dome tip, neck width, aneurysm area, aspect ratio, Longest dimension from the aneurysm neck to the dome tip (Dmax) to dome width, and height-width, Bottleneck factor, as well as wall shear stress (WSS), low WSS area (LSA), percentage of LSA (LSA%) and energy loss (EL) were estimated. Parameters between ruptured and un-ruptured groups were analyzed. Receiver operating characteristics were generated to check prediction performance of all significant variables. Results : Sixty-seven patients with MCA bifurcation aneurysm were included (31 unruptured, 36 ruptured). Dmax (p=0.008) was greater in ruptured group than that in un-ruptured group. D/W (p<0.001) and the percentage of the low WSS area ($0.09{\pm}0.13$ vs. $0.01{\pm}0.03$, p<0.001) were also greater in the ruptured group. Moreover, the EL in ruptured group was higher than that in unruptured group ($6.39{\pm}5.04$ vs. $1.53{\pm}0.86$, p<0.001). Multivariate regression analysis suggested D/W and EL were significant predictors of rupture of MCA bifurcation aneurysms. Correlation analyses revealed the D/W value was positively associated with the EL (R=0.442, p<0.01). Conclusion : D/W and EL might be the most two favorable factors to predict rupture risk of MCA bifurcation aneurysms.

Reducing frame rate and pulse rate for routine diagnostic cerebral angiography: ALARA principles in practice

  • Arvin R. Wali;Sarath Pathuri;Michael G. Brandel;Ryan W. Sindewald;Brian R. Hirshman;Javier A. Bravo;Jeffrey A. Steinberg;Scott E. Olson;Jeffrey S. Pannell;Alexander Khalessi;David Santiago-Dieppa
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권1호
    • /
    • pp.46-50
    • /
    • 2024
  • Objective: Diagnostic cerebral angiograms (DCAs) are widely used in neurosurgery due to their high sensitivity and specificity to diagnose and characterize pathology using ionizing radiation. Eliminating unnecessary radiation is critical to reduce risk to patients, providers, and health care staff. We investigated if reducing pulse and frame rates during routine DCAs would decrease radiation burden without compromising image quality. Methods: We performed a retrospective review of prospectively acquired data after implementing a quality improvement protocol in which pulse rate and frame rate were reduced from 15 p/s to 7.5 p/s and 7.5 f/s to 4.0 f/s respectively. Radiation doses and exposures were calculated. Two endovascular neurosurgeons reviewed randomly selected angiograms of both doses and blindly assessed their quality. Results: A total of 40 consecutive angiograms were retrospectively analyzed, 20 prior to the protocol change and 20 after. After the intervention, radiation dose, radiation per run, total exposure, and exposure per run were all significantly decreased even after adjustment for BMI (all p<0.05). On multivariable analysis, we identified a 46% decrease in total radiation dose and 39% decrease in exposure without compromising image quality or procedure time. Conclusions: We demonstrated that for routine DCAs, pulse rate of 7.5 with a frame rate of 4.0 is sufficient to obtain diagnostic information without compromising image quality or elongating procedure time. In the interest of patient, provider, and health care staff safety, we strongly encourage all interventionalists to be cognizant of radiation usage to avoid unnecessary radiation exposure and consequential health risks.

전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가 (The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography)

  • 이지원;정강교;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.121-126
    • /
    • 2015
  • 다중검출기전산화단층촬영장치(Multi-Detector Computed Tomography; MDCT)를 이용한 뇌혈관 진단을 위해 뇌혈관전산화단층촬영검사(Brain Computed Tomography Angiography; BCTA)검사 시 동일한 조영제 주입 후 관전압 변화에 따라 변화되는 뇌동맥의 CT Number 값을 통해 방사선량과 영상의 질 변화를 알아보고자 하였다. BCTA검사를 받기 위해 내원한 환자 50명을 대상으로 각 25명씩 두 그룹으로 나누어 관전압(A그룹: 80kVp, B그룹: 120kVp)을 제외한 모든 조건을 동일한 조건[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0 mm, Increment 5.0 mm, Delay Time 3.0s, Care Dose 4D(Demension ; D)]으로 하여 검사를 실시하였다. 얻어진 모든 영상에서 좌 대뇌동맥, 우대뇌동맥, 후 대뇌동맥, 뇌 실질조직 등 네 부위에 관심영역(Region of Interest; ROI)을 설정하여 의료영상 저장 전송 시스템(Picture Archiving Communications System; PACS, G3, Infinitt, Korea)에서 CT Number 값을 측정하여 정량적 평가와 정성적 평가, 유효선량을 비교 하였다. BCTA검사에서 얻어진 각각의 영상에서 CT Number를 이용한 영상평가 결과 80kVp로 검사한 영상이 120kVp 검사에 비해 신호 대 잡음비(Signal to Noise Ratio; SNR) 18%, 대조도 대 잡음비(Contrast to Noise Ratio; CNR)가 19%이상 높게 나타났다. 그리고 피폭선량의 경우 관전압 80kVp에서 120kVp를 적용한 영상에 비해 50% 이상 감소됨을 확인할 수 있었다. A그룹(25명)은 관전압 80kVp로 촬영을 하였으며 B그룹(25명)은 관전압 120kVp로 검사를 하여 영상의 화질 및 선량을 비교 평가하였다. 기존의 고관전압과 비교하여 관전압을 낮게 설정하여 검사할 경우 진단에 영향 없이 방사선량을 감소시킬 수 있어 매우 유용하리라 판단된다.

Intracranial Extension of Spinal Subarachnoid Hematoma Causing Severe Cerebral Vasospasm

  • Nam, Kyoung Hyup;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권6호
    • /
    • pp.527-530
    • /
    • 2014
  • Spinal subarachnoid hemorrhages (SAH) can extend into the intracranial subarachnoid space, but, severe cerebral vasospasm is rare complication of the extension of intracranial SAH from a spinal subarachnoid hematoma. A 67-year-old woman started anticoagulant therapy for unstable angina. The next day, she developed severe back pain and paraplegia. MRI showed intradural and extramedullar low signal intensity at the T2-3, consistent with intradural hematoma. High signal intensity was also noted in the spinal cord from C5 to T4. We removed subarachnoid hematoma compressing the spinal cord. The following day, the patient complained of severe headache. Brain CT revealed SAH around both parietal lobes. Three days later, her consciousness decreased and left hemiplegia also developed. Brain MRI demonstrated multiple cerebral infarctions, mainly in the right posterior cerebral artery territory, left parietal lobe and right watershed area. Conventional cerebral angiography confirmed diffuse severe vasospasm of the cerebral arteries. After intensive care for a month, the patient was transferred to the rehabilitation department. After 6 months, neurologic deterioration improved partially. We speculate that surgeons should anticipate possible delayed neurological complications due to cerebral vasospasm if intracranial SAH is detected after spinal subarachnoid hematoma.

Painless Dissecting Aneurysm of the Aorta Presenting as Simultaneous Cerebral and Spinal Cord Infarctions

  • Kwon, Jae-Yoel;Sung, Jae-Hoon;Kim, Il-Sup;Son, Byung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.252-255
    • /
    • 2011
  • Authors report a case of a painless acute dissecting aneurysm of the descending aorta in a patient who presented with unexplained hypotension followed by simultaneous paraplegia and right arm monoparesis. To our knowledge, case like this has not been reported previously. Magnetic resonance imaging of the brain and spine revealed hemodynamic cerebral infarction and extensive cord ischemia, respectively. Computerized tomography angiography confirmed a dissecting aneurysm of the descending aorta. The cause of the brain infarction may not have been embolic, but hemodynamic one. Dissection-induced hypotension may have elicited cerebral perfusion insufficiency. The cause of cord ischemia may be embolic or hemodynamic. The dissected aorta was successfully replaced into an artificial patch graft. The arm monoparesis was improved, but the paraplegia was not improved. In rare cases of brain and/or spinal cord infarction caused by painless acute dissecting aneurysm of the aorta, accurate diagnosis is critical because careless thrombolytic therapy can result in life-threatening bleeding.

Hemorrhagic Moyamoya Disease : A Recent Update

  • Fujimura, Miki;Tominaga, Teiji
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권2호
    • /
    • pp.136-143
    • /
    • 2019
  • Moyamoya disease (MMD) is a progressive cerebrovascular disease with unknown etiology, characterized by bilateral steno-occlusive changes at the terminal portion of the internal carotid artery and an abnormal vascular network formation at the base of the brain. MMD has an intrinsic nature to convert the vascular supply for the brain from internal carotid (IC) system to the external carotid (EC) system, as indicated by Suzuki's angiographic staging. Insufficiency of this 'IC-EC conversion system' could result not only in cerebral ischemia, but also in intracranial hemorrhage from inadequate collateral anastomosis, both of which represent the clinical manifestation of MMD. Surgical revascularization prevents cerebral ischemic attack by improving cerebral blood flow, and recent evidence further suggests that extracranial-intracranial bypass could powerfully reduce the risk of re-bleeding in MMD patients with posterior hemorrhage, who were known to have extremely high re-bleeding risk. Although the exact mechanism underlying the hemorrhagic presentation in MMD is undetermined, most recent angiographic analysis revealed the characteristic angio-architecture related to high re-bleeding risk, such as the extension and dilatation of choroidal collaterals and posterior cerebral artery involvement. We sought to update the current management strategy for hemorrhagic MMD, including the outcome of surgical revascularization for hemorrhagic MMD in our institute. Further investigations will clarify the optimal surgical strategy to prevent hemorrhagic manifestation in patients with MMD.

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

In-Stent Stenosis of Stent Assisted Endovascular Treatment on Intracranial Complex Aneurysms

  • Yoon, Kyeong-Wook;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권6호
    • /
    • pp.485-489
    • /
    • 2010
  • Objective : To introduce the frequency and segment analysis of in-stent stenosis for intracranial stent assisted endovascular treatment on complex aneurysms. Methods : A retrospective study was performed in 158 patients who had intracranial complex aneurysms and were treated by endovascular stent application with or without coil embolization. Of these, 102 patients were evaluated with catheter based angiography after 6, 12, and 18 months. Aneurysm location, using stent, time to stenosis, stenosis rate and narrowing segment were analyzed. Results : Among follow-up cerebral angiography done in 102 patients, 8 patients (7.8%) were shown an in-stent stenosis. Two patients have unruptured aneurysm and six patients have ruptured one. Number of Neuroform stents were 7 cases (7.5%) and Enterprise stent in 1 case (11.1%). Six patients demonstrated in-stent stenosis at 6 months after stent application and remaining two patients were shown at 12 months, 18 months, respectively. Conclusion : In-stent stenosis can be confronted after intracranial stent deployment. In our study, no patient showed symptomatic stenosis and there were no patients who required to further treatment except continuing antiplatets medication. In-stent stenosis has been known to be very few when they are placed into the non-pathologic parent artery during the complex aneurysm treatment, but the authors found that it was apt to happen on follow up angiography. Although the related symptom was not seen in our cases, the luminal narrowing at the stented area may result the untoward hemodynamic event in the specific condition.

Bilateral Vertebral Artery Dissecting Aneurysms : A Long Term Follow-up Results of Microsurgical Trapping and Proximal Occlusion

  • Kim, Young-June;Lee, Sang-Youl;Rhee, Woo-Tack;Jang, Yeon-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.318-322
    • /
    • 2007
  • Regarding the bilateral vertebral artery [VA] dissecting aneurysms, treatment strategy remains controversial because there have not been enough cases to reach a conclusion on the best treatment. We present a patient underwent staged microsurgical trapping and endovascular coiling for each dissecting aneurysm of bilateral VA presenting subarachnoid hemorrhage [SAH]. The ruptured side was managed by VA trapping procedure without any neurological deficit. Postoperative cerebral angiography revealed patent right PICA without filling of previous right dissecting aneurysm and spontaneous occlusion of the left dissecting aneurysm one month after trapping procedure. However, follow-up angiography revealed recanalization and growing of the left VA dissecting aneurysm one year after the operation. The patient underwent endovascular embolization using GDC for the proximal occlusion of the left VA and postoperative course was uneventful.

Giant Arachnoid Granulation Misdiagnosed as Transverse Sinus Thrombosis

  • Choi, Hyuk-Jin;Cho, Chang-Won;Kim, Yoon-Suk;Cha, Jae-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권1호
    • /
    • pp.48-50
    • /
    • 2008
  • We experienced a case of giant arachnoid granulation misdiagnosed as dural sinus thrombosis. A 66-year-old woman presented with a one month history of progressive occipital headache. Computed tomography angiography and cerebral angiography showed a round filling defect at the transverse sinus which was speculated as a transverse sinus thrombosis. Anticoagulation therapy was performed to prevent worsening of thrombosis for 2 weeks and then a Gadolinium-enhanced magnetic resonance imaging scan was performed. The filling defect lesion at the transverse sinus revealed a non-enhancing granule with central linear enhancement, which was compatible with giant arachnoid granulation. We checked the intrasinus pressure difference across the lesion the through the dural sinus in order to exclude the lesion as the cause of headache. Normal venous pressure with no significant differential pressure across the lesion was noted. Headache was treated with medical therapy.