• Title/Summary/Keyword: Cercon crown

Search Result 4, Processing Time 0.017 seconds

IN VITRO MARGINAL FIT OF THE COMPUTERAIDED MILLED CERCON CROWNS

  • Chang, Jae-Yoon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.306-313
    • /
    • 2005
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of sample size, measurement number, measuring , instruments, etc. And there have been few studies about the marginal fit of Computer-aided Cercon crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made using computer-aided milled Cercon crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and methods. The in vitro marginal discrepancies of computer-aided milled Cercon crowns and control groups (metal ceramic crowns) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared by milling machine. 30 crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. The means and standard deviations of the marginal fit were 85$\pm$22$\mu$m for the control group and 91$\pm$15$\mu$m for the Cercon crowns. The t-test of the marginal discrepancies between Cercon crowns and metal-ceramic crowns were performed. Significant differences were not found between groups (P=0.230>.05). Based on the criterion of 120$\mu$m as the limit of clinical acceptability, the mean marginal fits of Cercon crowns and metal-ceramic crowns were acceptable. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were 85$\pm$22$\mu$m for the control (metal-ceramic crowns), 91$\pm$15$\mu$m for Cercon crowns. 2. The Cercon crowns showed slightly larger marginal gap discrepancy than the control but marginal gap between Computer-aided milled Cercon crowns and metal ceramic crowns did not showed significant difference (P>.05). 3. The Cercon crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

In vitro study of fracture strength of provisional crown materials

  • Karaokutan, Isil;Sayin, Gulsum;Kara, Ozlem
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.27-31
    • /
    • 2015
  • PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at $37^{\circ}C$ for 24 hours, and then they were thermocycled (TC, $5000{\times}$, $5-55^{\circ}C$) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (${\alpha}$=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique.

A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System (CAD/CAM을 이용하여 제작한 전부도재관의 지르코니아 코핑 디자인에 따른 파절강도에 관한 연구)

  • Bulgan, L.;Cho, In-Ho;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.111-123
    • /
    • 2006
  • A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System L. Bulgan, In-Ho Cho, Soo-Yeon Shin Department of Prosthodontics, Graduate School, Dankook University The fracture strength of prosthesis is important, because it affects the function, and long term success of prosthesis and teeth. The purpose of this study was to compare the fracture strength of zirconia coping designs. Experimental test group were classified into three designs according to coping design, Modified design: Zirconia coping margin was located at 1mm above the axiogingival line angle. Collarless design: The coping margin terminated at the axiogingival line angle Butt design: The coping margin was extended to the finishing line of prepared margin. A $Cercon^{(R)}$(Degussa, Germany) CAD/CAM system was used to make the zirconia coping. Fracture strength was measured using loading machine at a cross head speed of 1mm/min. The results were statistically analyzed using the one-way ANOVA and multiple comparison test. Statistical significance was set in advance at the probability level of less than 0.05. The result : I. Collarless($738N{\pm}155N$) and Modified($755N{\pm}185N$) groups showed significantly a lower fracture strength than Butt($1057N{\pm}262N$) group(p<0.05). II. There were no statistical differences of the fracture strength between Modified($755N{\pm}185N$) and Collarless($738N{\pm}155N$) groups. III. When comparing the fractured surface, all the group showed porcelain fracture, which were fractured at the labial surface of baked porcelain The butt design of the zirconia coping has higher fracture strength than modified and collarless design.