• Title/Summary/Keyword: Ceramic restoration

Search Result 206, Processing Time 0.024 seconds

Study on the Demand Characteristics of Epoxy Resins Applied to the Restoration of Ceramics (도자기 복원에 사용되는 에폭시계 고분자수지의 요구 특성 연구)

  • Nam, Byeongjik;Jeong, Seri;Jang, Sungyoon
    • Journal of Adhesion and Interface
    • /
    • v.13 no.4
    • /
    • pp.171-181
    • /
    • 2012
  • The demand characteristics of the conventional 12 kinds of epoxy resins which have been used for restoration of the ceramic relics were investigated to provide standards of the effective materials in this study. The result of durability analysis showed that a liquid type is more effective in ceramic relics (low damage, high strength), and a paste type is more effective in earthenware relics (high damage, low strength). The result of workability analysis appears that the liquid type is higher than the paste type, and a slow curing type is higher than a fast curing type in surface hardness. Therefore, in the case of the liquid type which is hard to reprocess due to high surface hardness, it is necessary to conduct a study on improving physical properties by adding filler. The result of the gloss analysis on epoxy resins showed that the liquid type (colorless) has higher gloss than the paste type, and the slow curing type has higher gloss than the fast curing type in liquid types. CDK-520A/520B and Araldite SV 427-2/HV 427-1 showed the most similar gloss to $700^{\circ}C$ earthenware, Devcon 5 minute, EPO-TEK 301-2, and Quik Wood showed the most similar gloss to celadon and whiteware, Quik Wood, EPO-TEK 301-2, and Devcon 5 minute showed the most similar gloss to buncheongware. It is necessary for conservator to decide the range of the restoration surface by predicting the increase and decrease of the restoration surface because most of the epoxy resins caused the volume change in curing process.

Porcelain Fracture in Metal Ceramic, All ceramic and Zirconia restoration (금속도재, 전장도재, 지르코니아 수복물에서의 도재 파절)

  • Cheolyeon Kim
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.46-53
    • /
    • 2023
  • Porcelain fractures associated with metal ceramic(MC), all ceramic (AC), and zirconia restorations are common complications. Several factors of fracture are suggested; Property of materials, Design of the coping for metal ceramic, fabrication techniques, supporting structure, occlusal force, parafunctional habit are being considered. In this article, these factors are discussed in detail.

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

FINITE ELEMENT STRESS ANALYSIS OF A TOOTH RESTORED WITH CAD/CAM CERAMIC INLAY (CAD/CAM 세라믹 인레이로 수복한 치아의 응력분포에 관한 유한요소법적 연구)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.464-484
    • /
    • 2001
  • When restoring a tooth, the dentist tries to choose the ideal material for existing situation. One criterion that is considered is its suitability for restoring coronal strength. As more tooth structure is removed, the cusps are weakened and susceptible to fracture. Further, this increased deformation may cause the formation of intermittent gaps at the margin between the hard tissue and the restoration, facilitating marginal leakage. The improvements in ceramic materials now make it possible for alternatives to amalgams, composites, and cast metal to be of offered for posterior teeth. Of the materials used, ceramics most closely approximates the properties of enamel. The introduction of computer-aided design/computer-aided manufacture(CAD/CAM) systems to restorative dentistry represents a major technological breakthrough. It is possible to design and fabricate ceramic restorations at a single appointment. Additionally, CAD/CAM systems eliminate certain errors and inaccuracies that are inherent to the indirect method and provide an esthetic restoration. The aim of this investigation was to study the loading characteristics of CAD/CAM ceramic inlay and to compare the stress distribution and displacement associated with different designs of cavity(the isthmus width and cavity depth). A human maxillary left first premolar was prepared with standard mesio-occlusal cavity preparation, as recommended by the manufacturer Ceramic inlay was fabricated with CEREC 2 CAD/CIM equipment and cemented into the prepared cavity. Three dimensional model was made by the serial photographic method. The cavity width was varied $\frac{1}{3}$, $\frac{1}{2}$ and $\frac{2}{3}$ of intercuspal distance between buccal and lingual cusp tip. The cavity depth was varied 1.5mm and 2.3mm. So six models were constructed to simulate six conditions. A point load of 500N was applied vertically onto the first node of the lingual slope from the buccal cusp tip. The stress distribution and displacement were solved using ANSYS finite element program(Swanson Analysis System). (omitted)

  • PDF

The Effect of Veneering Techniques on the Color Parameters of Y-TZP Based All Ceramic Restoration of Varying Ceramic Core Thickness (지르코니아 코어 두께에 따른 전부도재관의 상부도재 축성방법이 보철물 색조에 미치는 영향)

  • Huh, Sung-Yoon;Son, Ho-Jung;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • The aim of study was to compare the color parameters and mean color difference of porcelain specimens by different veneering technique in order to examine the effect of veneering technique on esthetics of yttria-stabilized tetragonal zirconia polycrystalline(Y-TZP) all ceramic restoration. Three groups of square-shaped core ceramic specimens(14mm in diameter and 0.3, 0.5, 0.7 mm) and two groups of veneering ceramic specimen were prepared for analysis. Color parameter($L^*,a^*,b^*$) and color difference of zirconia core squares and core-veneer specimens were measured with ShadeEye $NCC^{(R)}$ spectrophotometer, respectively. Mean color difference(${\Delta}E^*$)were calculated using color difference formula. Two-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}=0.05$). ${\Delta}E^*$ values were not significantly affected by core thickness and veneering porcelain(p=0.083). The color differences(${\Delta}E^*$) of core-veneer specimens with 0.5, 0.7 mm-A1,A2,A3.5 shade were mostly below 3.7 which was within the clinically acceptable range, while color differences between 0.3 mm-A1,A2 showed more than 3.7. All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Clinical performance of esthetic ceramic partial-coverage restorations with supra-gingival margin using minimally invasive tooth preparation method according to the concept of adhesive dentistry (접착치의학 개념에 따른 최소 침습적 치아 삭제법을 적용한 심미적인 치은 연상 변연 도재 부분피개관 수복 증례)

  • Hong, Myung-Sik;Choi, Yu-Sung;Lee, Jong-Hyuk;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.319-332
    • /
    • 2021
  • With the rapid development of aesthetic ceramic materials and resin adhesives, the transition from metal ceramic crown to all-ceramic restoration is being actively carried out. When making porcelain restorations, the advantages can be maximized only when appropriate forms and techniques are used. Recently, an esthetic partial-coverage restoration method with supra-gingival margins was introduced by applying a minimally invasive tooth removal method that preserves enamel as much as possible and enhances adhesion efficiency. Through this, various advantages such as minimization of tooth structure removal and ease of excess cement removal can be obtained. In addition, since this manufacturing method does not require cord packing, it is possible to save time for impression taking and reduce patient discomfort. Furthermore, the margins can be clearly obtained without the intervention of gingival fluid or blood, making it possible to manufacture more accurate restorations. In the following cases of patients with partial tooth defects, esthetic ceramic partial-coverage restorations with supra-gingival margin was applied using minimally invasive tooth preparation method according to the concept of adhesive dentistry. Therefore, unnecessary tooth abutment preparation was prevented and residual tooth structure could be preserved as much as possible. After delivery of the ceramic partial-coverage restorations, favorable outcome was obtained.

Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

  • Seo, Jae-Min;Ahn, Seung-Geun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.241-244
    • /
    • 2014
  • Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

CAD/CAM Zirconia All Ceramic Restoration and Red-White Esthetics

  • Jo, Jong-Man
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • For the prosthodontic results which are compatible with esthetics to be fulfilled, the first prerequisite would be periodontal intervention and stability, the second one may be functional competency and the ultimate goal should be ascribed to esthetic considerations. Other words, esthetic dentistry is a whole entity which encompasses the biological stability of the periodontium, physical accuracy of the prosthodontic structure and finally, the beauty which can be found in natural dentition. It also implies the harmonized lip line which reveals the well-balanced tooth morphology and health gum profiles (Red-White Esthetics). Largely, there lie some differences in the input system of the 3-dimentional data from the prepared abutments between respective computer-assisted systems available now. But the manufacturing systems (CAM) are very similar between them, to say, comprise numeric control systems with whole 3-dimensional milling units according to the restorations to be made. Now the author is going to present CAD/CAM Zirconia All Ceramic Restoration on the topics for the Red-White Esthetics, periodontal control and maintenance, treatment for the discolored teeth, post & core build-up works for the devitalized teeth, characteristics of the Zirconium oxide All Ceramics, fabrication procedures, clinical considerations and its application to diverse clinical situations.

  • PDF

Laminate production by manufacturing ceramic casting body and laminating using IPS Empress: a pressure casting method (가압주조방식인 IPS Empress로 세라믹 주조체를 제작 후 적층 형 성한 라미네이트 제작 증례)

  • Wook Tae Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.3
    • /
    • pp.81-86
    • /
    • 2023
  • Purpose: This study aimed to observe the effect of laminate veneer on patient's teeth based on the manufacturing of laminate veneer restorations, which are produced by fabricating a ceramic cast body using IPS Empress, a pressure casting method and then forming the veneer by layering. Subsequently, we assessed the potential of its clinical application. Methods: This study discusses and preserves various treatment plans, such as diagnostic wax-up and treatment room diagnosis, for patients who visit the hospital to improve the appearance of teeth due to diastema of maxillary teeth, inexperienced resin filling, lack of esthetics, and external teeth. A ceramic cast body is constructed using IPS Empress, which is an effective and aesthetic restoration pressure casting method to restore the veneer with a laminate made by layering. Results: Compared with the preoperative state, the frontal view of the patient after the final restoration showed the formation of a natural smile line; the space between the central and lateral incisors was filled in synchronously with the adjacent teeth. In addition, the emergence profile is maintained by reducing the over-contour as much as possible. Conclusion: The patient's quality of life is improved by providing them with a satisfactory natural smile.

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.