• 제목/요약/키워드: Ceramic crown

검색결과 229건 처리시간 0.02초

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

Retrospective clinical and radiographic evaluation of restored endodontically treated teeth

  • Paula Pontes Garcia ;Aline Cappoani ;Ricardo Susin Schelbauer ;Gisele Maria Correr ;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.49.1-49.11
    • /
    • 2020
  • Objectives: The aim of this study was to perform a clinical and radiographic analysis of endodontically treated teeth (ETT) restored with cast metal posts (CMPs) or prefabricated glass fiber posts (GFPs) and crowns. Materials and Methods: Fifty ETT were restored with 25 CMPs and 25 GFPs at a private dental clinic between 2001 and 2016. The restorations consisted of 12 all-ceramic crowns, 31 metal-ceramic crowns, and 7 composite resin crowns. Demographic data, type of teeth, type of post-and-core system, time of placement, crown restorations, the number of proximal contacts, the type of antagonist, and reports of any complications after post-and-core placement were recorded for each patient. Assessments were performed at baseline (radiographic) and follow-up (radiographic and clinical). Data were analyzed by the McNemar test, the Pearson χ2 test, and Kaplan-Meier survival curves (α = 0.05). The mean follow-up was 67.6 months. Results: No significant difference was observed for any of the radiographic parameters when the baseline and final radiographs were compared. In the clinical evaluation, anatomical form (p = 0.009) and occlusion (p = 0.001) showed significant differences according to the type of crown restoration; specifically, metal-ceramic and all-ceramic crowns outperformed composite resin crowns. Conclusions: CMPs and GFPs showed favorable results for restoring ETT after 6 years of follow-up. All-ceramic and metal-ceramic crowns showed higher survival rates and better clinical outcomes.

치과 도재용착 주조관용 비귀금속 합금의 반복주조가 기계적 특성 및 미세조직에 미치는 영향 (A Study on How Cyclic Casting of Base Metal Alloy for Dental Ceramic Crown May Effects upon Its Mechanical Properties and Microstructure)

  • 최운재;신무학;정희선;고명원
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.9-20
    • /
    • 2003
  • Using a nickel-chrome casting alloy called 'Rexillium V' which is also available as base metal alloy for dental ceramic crown, 4 types of mixtures(A, B, C, D) with old and new metal were prepared for cyclic casting. The results of cyclic casting can be outlined as follows: 1. For Vickers hardness after casting, specimen A and D tended to have lower hardness in the course of cyclic casting, while specimen B and C tended to higher hardness. 2. The results of X-ray diffraction analysis showed that major crystal phase contained nickelchrome compounds and carbide. 3. The observation results of SEM photographs after cyclic casting show that there was a significant tendency to have similar structures among experimental groups. 4. The results of EDX analysis after cyclic casting showed that there were little differences in chemical composition between parent metal and base metal alloy. Although industrial nickel-chrome cast alloy did not show any significant change in material properties even through cyclic casting over several times, it is recommended that more there be more in-depth studies on how to detect any potential corrosion, discoloration and toxication of dental ceramic crown implanted in patient's oral cavity.

  • PDF

지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향 (The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown)

  • 이서연;정인성;전병욱
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.111-117
    • /
    • 2016
  • Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.

출력 지지대 두께가 선택적 레이저 용융법으로 제작된 금속 하부구 조물 적합도에 미치는 영향 (Effect of support thickness on the adaptation of Co-Cr alloy copings fabricated using selective laser melting)

  • 김재홍;김세연
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.67-73
    • /
    • 2023
  • Purpose: This in vitro study aimed to evaluate the clinical acceptability of precision of fit of the support thickness of Co-Cr alloy copings fabricated using selective laser melting (SLM). Methods: Thirty dental stone models of maxillary left molar abutments were manufactured, images were taken using a scanner, and a computer-aided design program was used to design the form of a conventional metal ceramic crown coping. Overall, 30 single copings were made from Co-Cr alloy using SLM and divided into three support radius groups (0.1, 0.25, and 0.35 mm) of 10 for each. Digitized data were superimposed with three-dimensional inspection software to quantitatively obtain the machinability of a ceramic crown coping, and visual differences were confirmed using a color map. The root mean square values of the ceramic crown coping group were statistically analyzed using one-way analysis of variance (α=0.05). Results: The precision of fit was superior with 0.25 mm compared with 0.1 mm and 0.35 mm, and the results exhibited significant differences (p<0.05). All specimens showed that various support thicknesses did not exceed the clinically permitted value of 120 ㎛, which mean that more than 0.1 mm and 0.35 mm of support radius for SLM was adequate. Conclusion: The support thickness of Co-Cr alloy restoration fabricated using SLM is shown to affect the adaptation.

PVP 결합제를 이용한 수계용 세라믹테이프의 제조 (Fabrication of Water-based Ceramic Tapes Using PVP As Binder)

  • 박일석;조유정;이명현;최세영;이득용;김대준
    • 한국세라믹학회지
    • /
    • 제38권11호
    • /
    • pp.1060-1066
    • /
    • 2001
  • 세라믹 인공치관으로 응용을 위해 생체친화적이며 용매에 용해가 잘되고 연소 후 잔류물이 남지 않는 결합제인 PVP로 수계용 알루미나 테이프를 제조하였다. 알루미나 테이프의 인장강도는 결합제(b)와 가소제(p)의 비(b/b+p))에 의해, 그리고 소결체 수축과 밀도는 알루미나(a)와 유기물(o)의 비 (a/(a+o))에 의해 영향을 받았다. 소결된 가공성 알루미나 테이프에 유리를 침투시켜 강화된 세라믹 인공치관용 복합체의 강도는 소결밀도가 증가할수록 높은 값을 보였다.

  • PDF

저한성 외배엽 이형성증을 가진 소아 환자에서 의치 유지력 향상을 위한 보철 치료 전략: 두 가지 증례 보고 (Prosthetic Treatment Strategies for Improving Denture Retention in Pediatric Patients with Hypohidrotic Ectodermal Dysplasia: a Report of Two Cases)

  • 전홍주;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.483-494
    • /
    • 2023
  • 이 논문은 저한성 외배엽 이형성증(Hypohidrotic Ectodermal Dysplasia, HED)으로 인한 부분무치증을 가진 소아 환자에게 의치의 유지력 증가 방법에 관한 두 가지 증례를 보고한다. 두 환자 모두 다수의 치아 결손 및 원추형의 견치와 치조골 위축, 골격적 III급 경향이 나타났다. 첫 번째 증례에서는, 변형된 형태의 Conical-Crown Retained Denture (CCRD)를 이용해 견치를 피개하였다. 이 방법은 치아를 삭제하거나 코핑 없이 진행되었다. 두 번째 증례에서는, 심한 치조제 흡수와 함께 하악 좌측 견치가 원심으로 경사지어 맹출한 상황에서, 하이브리드 세라믹 크라운을 사용하여 견치를 수복한 후, 흡착성 원리를 이용한 클라스프 유지 가철식 의치로 변경하였다. 두 환자는 현재 보철물 유지 관리 및 성장양상을 평가하기 위해 주기적으로 치료를 받고 있다. 이 증례는 HED로 인하여 의치의 유지력이 부족한 소아 환자에게 적용된 창의적인 보철 치료 방법을 제시하였다.

Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구 (MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY)

  • 정희찬;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료 (Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion)

  • 이소진;김유진;박영범;조규성;정문규
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.204-209
    • /
    • 2012
  • 치은연 하방에 치아 우식증이나 치아 파절이 발생했을 때, 치아를 탈구시켜 즉시 정출시키는 외과적 정출술을 이용한 치관 연장술은 자연치를 보존하고 추가적인 치주적 수술 없이 단기간에 심미적인 보철 치료를 가능하게 한다. 본 환자는 16세 남환으로 본원 보존과로부터 상악 좌측 중절치의 심미 수복을 위해 본원 보철과로 의뢰되었다. 상악 좌측 중절치는 근관치료가 되어 있었으며 치관-치근 파절로 인해 협측 치관 길이는 4mm였으며 구개측 판막을 열었을 때 근심 구개측 치경부 파절 범위는 치은 하방 3-4mm에 위치하였다. 외과적 정출술을 통한 치관연장술을 시행하였으며 경과 관찰 및 임시 치아의 단계를 거쳐 3개월 후에 전부 도재관으로 수복하여 만족할 만한 임상결과를 얻을 수 있었다.