• 제목/요약/키워드: Cephalometric measurement

검색결과 92건 처리시간 0.021초

계수 영상화된 측모 두부방사선 규격사진의 계측오차 (ERRORS IN DIGITIZED LATERAL CEPHALOMETRIC RADIOGRAPHY)

  • 전선두;조봉혜;나경수
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.105-116
    • /
    • 1997
  • The purpose of this study is to evaluate the cephalometric reproducibility in digitized cephalometric radiography by comparing the measurement errors between the remeasured and retaken conventional and digitized lateral cephalometric radiography. The mean of the differences and error percentage of each cephalometric measurement were obtained using 96 lateral cephalometric radiography from 48 patients between the age of 11 and 13. The results were as follows; 1. The repeated measurement group of conventional radiography showed least amount of mean differences while those of the retaken measurement group of digitized image showed largest amount of mean differences in every measurement. 2. The measurements which showed statistically significant difference between the conventional radiography and digitized image were S-Go, Ar-Go, S-Ar-Go and S-sN-sNT in repeated measurement group. 3. The measurements which showed statistically significant difference between the repeated and retaken measurement groups were N-S-Ar, MP-Ll and S-sN-sPog in conventional radiography and S-N, Go-Me and N-A in digitized Image. 4. Large amount of error percentage was shown at A-N-B and N-A in retaken measurement group of conventional radiography and N-S-Ba and A-N-B in retaken measurement group of digitized image. 5. The amount of error percentage at Ar-Go and N-S- Ar in retaken measurement group of conventional radiography and S-N, N-A, S-N-B and N-S-Ba in retaken measurement group of digitized image was more than double than those from remeasured groups.

  • PDF

3-Dimensional analysis for class III malocclusion patients with facial asymmetry

  • Kim, Eun-Ja;Ki, Eun-Jung;Cheon, Hae-Myung;Choi, Eun-Joo;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.168-174
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the correlation between 2-dimensional (2D) cephalometric measurement and 3-dimensional (3D) cone beam computed tomography (CBCT) measurement, and to evaluate the availability of 3D analysis for asymmetry patients. Materials and Methods: A total of Twenty-seven patients were evaluated for facial asymmetry by photograph and cephalometric radiograph, and CBCT. The 14 measurements values were evaluated and those for 2D and 3D were compared. The patients were classified into two groups. Patients in group 1 were evaluated for symmetry in the middle 1/3 of the face and asymmetry in the lower 1/3 of the face, and those in group 2 for asymmetry of both the middle and lower 1/3 of the face. Results: In group 1, significant differences were observed in nine values out of 14 values. Values included three from anteroposterior cephalometric radiograph measurement values (cant and both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). In group 2, comparison between 2D and 3D showed significant difference in 10 factors. Values included four from anteroposterior cephalometric radiograph measurement values (both maxillary height, both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). Conclusion: Information from 2D analysis was inaccurate in several measurements. Therefore, in asymmetry patients, 3D analysis is useful in diagnosis of asymmetry.

디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교 (The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph)

  • 김미자;허경회;이원진;허민석;이삼선;이진구;안병근;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권1호
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

안와 경사의 분석을 위한 정모 두부규격방사선사진, 3D-CT의 유용성 평가 (VALIDITY OF POSTERIOR ANTERIOR CEPHALOMETRIC AND 3D-CT FOR ORBITAL CANTING ANALYSIS)

  • 김진욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권6호
    • /
    • pp.546-553
    • /
    • 2008
  • Purpose: The purpose of this study was to estimate validity of posterior anterior cephalometric and 3D-CT for orbital canting analysis. Materials and methods: Three trained observers classified two patients group using standardized frontal photographs of facial asymmetry patients. Group A consisted of patients with facial asymmetry and orbital canting(n=19), and group B consisted of patients with only facial asymmetry(n=43). Orbital canting was measured with line of bilateral inferior orbitale. Orbital canting measurement was done with posterior anterior cephalometric and 3D-CT. Each horizontal reference line was established by bilateral GWSO(cephalometric), FZS(3D-CT). Maxillary canting and mandibular deviation angle were also measured and analyzed with orbital canting. Results: The mean orbital canting was $3.03{\pm}1.00^{\circ}$ in Group A and $1.11{\pm}0.76^{\circ}$ in Group B in frontal photograph. The mean orbital canting was $1.20{\pm}0.74^{\circ}$ in group A and $1.22{\pm}0.65^{\circ}$ in group B by cephalometric analysis(p>0.05). In 3D-CT, orbital canting was almost paralleled with horizontal reference line. The orbital canting, maxillay canting and mandibular deviation between two groups showed no significant differences except madibular deviation in 3D-CT. Conclusion: Common analysis of posterior anterior cephalometric and 3D-CT is not valide method to evaluate orbital canting for facial asymmetry patients with orbital canting.

디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과 (Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position)

  • 김미자;최보람;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

Analysis of Measurement Accuracy for Craniovertebral Junction Pathology : Most Reliable Method for Cephalometric Analysis

  • Lee, Ho Jin;Hong, Jae Taek;Kim, Il Sup;Kwon, Jae Yeol;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권4호
    • /
    • pp.275-279
    • /
    • 2013
  • Objective : This study was designed to determine the most reliable cephalometric measurement technique in the normal population and patients with basilar invagination (BI). Methods : Twenty-two lateral radiographs of BI patients and 25 lateral cervical radiographs of the age, sex-matched normal population were selected and measured on two separate occasions by three spine surgeons using six different measurements. Statistical analysis including intraclass correlation coefficient (ICC) was carried out using the SPSS software (V. 12.0). Results : Redlund-Johnell and Modified (M)-Ranawat had a highest ICC score in both the normal and BI groups in the inter-observer study. The M-Ranawat method (0.83) had a highest ICC score in the normal group, and the Redlund-Johenll method (0.80) had a highest ICC score in the BI group in the intra-observer test. The McGregor line had a lowest ICC score and a poor ICC grade in both groups in the intra-observer study. Generally, the measurement method using the odontoid process did not produce consistent results due to inter and intra-observer differences in determining the position of the odontoid tip. Opisthion and caudal point of the occipital midline curve are somewhat ambiguous landmarks, which induce variable ICC scores. Conclusion : On the contrary to other studies, Ranawat method had a lower ICC score in the inter-observer study. C2 end-plate and C1 arch can be the most reliable anatomical landmarks.

두부자세에 따른 근활성과 측모두부방사선계측치의 변화에 관한 연구 (Changes of Muscle Activity and Cephalometric Variables Related to Head Posture)

  • 김병욱;한경수
    • Journal of Oral Medicine and Pain
    • /
    • 제24권2호
    • /
    • pp.189-206
    • /
    • 1999
  • This study was performed to investigate the factors affecting muscle activity and cephalometric variables according to change of head postures. For this study, 150 patients with temporomandibular disorders and 80 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the normal group, respectively. Head position to body-midline in frontal plane and upper quarter posture to body plumb line in sagittal plane were observed clinically and electromyographic(EMG) activity of anterior temporalis, masseter, sternocleidomastoideus, and trapezius on clenching were recorded with $BioEMG^{(R)}$ in four head postures, which were natural head posture(NHP), forward head posture(FHP), $20^{\circ}$ upward head posture(UHP), and $20^{\circ}$ downward head posture(DHP). Cephaloradiographs were also taken in the same head postures as in EMG taking, but that was taken only in NHP for the patient group. Cephalometric variables measured were SN angle, CVT angle, atlas inclination angle, occlusal plane angle, Me-C2 angle, pharyngeal width, occiput~axis distance, area of pharyngeal space, and cervical curvature. The data were analyzed by SAS statistical program. The results of this study were as follows : 1. Between the patient and the normal group, there were significant difference in distance from plumb line to acromion, eye-tragus angle, electromyographic activity of the four muscles, and cephalometric variables of linear measurement. 2. There was no consistent pattern of correlation between upper quarter posture, EMG activity and cephalometric variables in any case without relation to cervical curvature and head position in frontal plane. 3. Sternocleidomastoid muscle only showed variation of electromyographic activty with changes of head postures, but all the muscles did show correlation with head postures. 4. All the cephalometric variables measured in this study showed difference of mean value by head posture, and CVT angle, pharyngeal width, occiput-atlas distance, and area of pharyngeal space showed correlation between these variables with change from NHP to FHP, and from NHP to UHP.

  • PDF

하악전돌증 환자에서 내측 익돌근 근력측정 및 분석 (MEASUREMENT AND ANALYSIS OF THE RESISTANT MUSCLE FORCE OF MEDIAL PTERYGOID MUSCLE IN THE MANDIBULAR PROGNATHIC PATIENTS)

  • 홍종락;강나라;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권2호
    • /
    • pp.131-135
    • /
    • 2004
  • The purpose of this study was to evaluate the resistant force of medial pterygoid muscles against the mandibular advancement and distraction to anterior, and inquire into the relationship between medial pterygoid muscles and cephalometric variables. Sixty six patients with class III malocclusion underwent bilateral sagittal splitting of ramus with intraoralvertico-sagittal ramus osteotomy for mandibular set-back. The spring scale was used to measure the resistance of medial pterygoid muscles after splitting of ramus. Skeletaldental cephalometric analysis was made and statistic package was used for correlation between resistance and cephalometric variables. The resistant force of the right medial pterygoid muscle was greater than the left one in Koreans with class III malocclusion, and the force had a linear regression relationship with facial depth. The results suggested that facial depth has significant correlation with the resistance of medial pterygoid muscle, which can be acquired from patient's cephalometric analysis.

Validation of three-dimensional digital model superimpositions based on palatal structures in patients with maximum anterior tooth retraction following premolar extraction

  • Liu, Jing;Koh, Kyong-Min;Choi, Sung-Hwan;Kim, Ji-Hoi;Cha, Jung-Yul
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.258-267
    • /
    • 2022
  • Objective: This study aimed to evaluate the superimposition accuracy of digital modes for measuring tooth movement in patients requiring anterior retraction after premolar extraction based on the proposed reference regions. Methods: Forty patients treated with bilateral maxillary first premolar extraction were divided into two groups: moderate retraction (< 7.0 mm) and maximum retraction (≥ 7.0 mm). Central incisor displacement was measured using cephalometric superimpositions and three-dimensional (3D) digital superimpositions with the 3rd or 4th ruga as the reference point. The Wilcoxon signed-rank test and linear regression analyses were performed to test the significance of the differences and relationships between the two measurement techniques. Results: In the moderate retraction group, the central incisor anteroposterior displacement values did not differ significantly between 3D digital and cephalometric superimpositions. However, in the maximum-retraction group, significant differences were observed between the anteroposterior displacement evaluated by the 3rd ruga superimposition and cephalometric methods (p < 0.05). Conclusions: This study demonstrated that 3D digital superimpositions were clinically as reliable as cephalometric superimpositions in assessing tooth movements in patients requiring moderate retraction. However, the reference point should be carefully examined in patients who require maximum retraction.

McNamara법에 의한 한국인 악안면골의 성장 변화에 관한 연구 (ROENTGENOCEPHALOMETRIC STUDY OF CRANIOFACIAL GROWTH BY MCNAMARA ANALYSIS ON TEEN AGE WITH NORMAL OCCLUSION)

  • 권배근;유영규
    • 대한치과교정학회지
    • /
    • 제15권2호
    • /
    • pp.327-340
    • /
    • 1985
  • This study was performed to establish the Cephalometric standards and growths change of Korean Teen aged group by McNamara's Analysis. The data from Cephalometric films of 161 male and 205 female subject aged from 10 to 18 years of Normal Korean were used for this study. The following results were obtained: 1. Means, standard deviation from measured values in each age group and sexual values were obtained. 2. Greater measurement stowed in male than female in Condylion to point A, Condylion to Gnathion, MaxilloMandible differential and ANS to mouton in linear measurement of 18 age group. 3. Condylion to point A, Condylion to gnathion, MaxilloMandible differential and ANS to Menton are increased as the age increased. 4. Facial axis angle and Mandible plane angle of 15 and 18 aged group showed less value than that of 10,11,12 age group. 5. There was no significant value changes of Lower incisor to A-Po, SNA angle and Lower pharynx by the increasing of age.

  • PDF