• 제목/요약/키워드: Centrifugal

검색결과 1,669건 처리시간 0.032초

외상성 대동맥 파열: 4례 보고 (Traumatic Aortic Rupture - Report of 4 Case -)

  • 윤태진
    • Journal of Chest Surgery
    • /
    • 제24권7호
    • /
    • pp.725-731
    • /
    • 1991
  • Four patients with traumatic rupture of aorta underwent operative repair at Seoul national university hospital. All cases were confirmed by preoperative aortography. Rupture site was aortic isthmus or just distal to it. Operations were somewhat delayed due to the low degree of suspicion and difficulties in diagnosis: ranging from 5 hours to 8 days. Operation was performed as same manners in all cases: resection of the ruptured portion and tubular woven dacron graft interposition in conjunction with shunt or bypass procedures, TDMAC-Heparin shunt between ascending and descending aorta was used in 3 cases, and LA-femoral centrifugal pump was used in one case. There were no intraoperative or postoperative mortality. Hoarseness was developed in all patients but paraplegia or other significant complications were not found in any of patients. We concluded that 1] high degree of suspicion is essential in the early diagnosis and treatment of traumatic aortic rupture and 2] any kind of shunt or bypass procedure is necessary in operative repair of traumatic aortic rupture and use of centrifugal pump without systemic heparinization is easier and safer procedure than others for the maintenance of adequate distal flow.

  • PDF

흡입저항이 높은 원심홴 소음특성에 관한 연구 (Study on the Noise Characteristic of Centrifugal Fan operating at High Pressure Region)

  • 정윤영;박진원;전완호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1011-1014
    • /
    • 2006
  • Turbo blower generates high peaks when it operates at high pressure region. The fan of the air-cleaner system, operates especially high pressure region due to several filters, generates high noise level. In this case, the tonal sound of BPF makes people annoyance. The blower of air-cleaner has several high resistance filters in its inlet area and rotates above 900rpm Moreover, for the compact design, the size of the blower should be reduced 10%. The reduced diameter of blower makes low flow rate and high noise level. In order to reduce the noise, new blade shape was suggested and optimized

  • PDF

상부유입식 전기 Cyclone-Bag Filter의 특성 (Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet)

  • 여석준
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF

Redesign and Evaluation of a Chickpea Harvester

  • Golpira, H.
    • Journal of Biosystems Engineering
    • /
    • 제40권2호
    • /
    • pp.102-109
    • /
    • 2015
  • Purpose: Slow manual harvesting of rain-fed chickpeas cultivated in fallow fields in developing countries have encouraged the design of a mechanical harvester. Methods: A tractor-pulled harvester was built, in which a modified stripper header detached pods from an anchored plant and a chain conveyor transferred material. The stripper harvester was redesigned to use: 1) the maneuverability of tractor-mounted frames, 2) the adaptability of floating headers, and 3) the flexibility of pneumatic conveyors. Results: A mobile vacuum conveyor, which was an innovator open system, was designed for the dilute phase transferring mode for both grain and material other than grain. A centrifugal fan transferred harvested material to a cyclone separator that settled harvested material in a grain tank 1 m high. The machine at the spot work rate of $0.42ha{\cdot}h^{-1}$ harvested chickpea pods equal to the output of 16.6 farm laborers. Conclusion: The low cost and reasonable projected purchase price are the advantages of the concept. Additionally, the shattering loss reduction confirms the feasibility of the prototype chickpea harvester for commercialization.

보강재 침하를 허용하는 연결시스템을 적용한 보강토옹벽의 거동 (Behavior of Reinforced Earth Retaining Wall for Connector System Driving the Settlement of Reinforcement)

  • 오종근;정종기;이송
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.156-161
    • /
    • 2006
  • Recently, construction of soil-reinforced segmental retaining walls which used geosynthetics are being increased day by day due to its construction efficiency, economic efficiency, and its aesthetic view. The conventional reinforced earth retaining wall has the connector system to fix the reinforcement and block However, this system may cause the crack of block and the rupture of reinforcement due to the stress concentration near the face of reinforced earth retaining wall In this study, the new connector system, which is able to allow the settlement of reinforcement, was applied to analyze the effect of connector system of reinforced earth retaining wall The connection strength tests and centrifugal tests for both the conventional reinforced earth retaining wall and the settlement reinforced earth retaining wall were performed to compare the results

  • PDF

직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법 (Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach)

  • 박태건;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

틸팅전동차용 추진 및 제어시스템 설계에 관한 연구 (The Study of Main Circuit and Control System Design for EMU Tilting Vechile)

  • 한성호;이수길;송용수;이은규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1112-1114
    • /
    • 2006
  • Tilting train has been developed to increase the operational speed of the trains on conventional lines which have many curves. This train are tilted at curves to compensate for unbalanced carbody centrifugal acceleration to a greater extent than compensation produced by the track cant, so that passengers do not feel centrifugal acceleration and thus trains can run at higher speed at curves. This paper show that results of normal capacity calculations of the electrical equipments such as Main transformer, PWM converter, VVVF inverter, traction motor in TTX(tilting train express) with maximum operation speed 180km/h

  • PDF

도장부스 수조 내 슬러지 처리 시스템의 개발 (Development of the Sludge Treatment System in Water Bath of Painting Booth)

  • 이찬;차상원;유영돈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.259-266
    • /
    • 2004
  • Developed is a sludge treatment system for introducing the waste water mixture with paint sludge from the water bath of paint booth and for recycling cleaned water to paint booth after sludge separation. Floated sludge is introduced from the water surface in the bath by using floating skimmer, and is conveyed by pump to the centrifugal separator where sludge and cleaned water are separated. From the operation results of the present sludge treatment systems applied in actual paint booths, paint sludge can be separated automatically and effectively from water bath with its water content of $60-70\%$, and sludge-free clean water is returned to paint booth.

  • PDF

복합 열원 공조시스템의 최적 제어 알고리즘 (Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

유선곡률법에 의한 원심압축기 회전차 내부유동의 수치해석 (Numerical Calculation of Flows through Impeller of Centrifugal Compressors by Streamline Curvature Method)

  • 강신형;신영섭
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.87-96
    • /
    • 1989
  • Flows through impellers of centrifugal compressors are calculated by a streamline curvature method. A method for the exit boundary condition is suggested in the present paper. Flow angles are assumed to be deviated from the blade angle parabolically. The maximum deviation is adjusted for the whole angular momentum to balance with the empirically estimated value by using Stanitz' slip-factor. The present method is verified to reasonably simulate flows through the impeller, when the 3-dimensionality of the flow is not strong. It is also shown that the method can be applied for the design of the splitter in the impeller.

  • PDF