• Title/Summary/Keyword: Central venous

Search Result 197, Processing Time 0.027 seconds

Analysis of neonatal sepsis in one neonatal intensive care unit for 6 years (최근 6년간 단일 신생아중환자실에서 발생한 패혈증 환자의 분석)

  • Chun, Peter;Kong, Seom-Gim;Byun, Shin-Yun;Park, Su-Eun;Lee, Hyung-Du
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.495-502
    • /
    • 2010
  • Purpose : Sepsis is a significant cause of morbidity and mortality in the newborn, particularly in preterm. The objective of this study was to analyze the incidence rate, causative pathogens and clinical features of neonatal sepsis in one neonatal intensive care unit (NICU) for 6 years. Methods : This study was retrospectively performed to review the clinical and laboratory characteristics including sex, gestational age, birth weight, Apgar score, length of hospitalization, length of total parenteral nutrition, presence of central venous catheter, underlying diseases, laboratory findings, microorganisms isolated from blood culture, complications and mortality in 175 patients between January 2003 and December 2008. Results : 1) Sepsis was present in 175 of 3,747 infants for 6 years. There were more gram-positive organisms. 2) The gram-negatives were more prevalent in preterm. There were no significant differences of other clinical features between two groups. 3) Underlying diseases were found in 73.7%, and the most common disease was cardiovascular disease. The most common organisms of gram-positives and gram-negatives were methicillin resistant Staphylococcus aureus (MRSA) and Serratia marcescens. 4) There was statistically significant difference on platelet counts between two groups (P<0.05). 5) Complications were found in 18.3% and septic shock was the most common. MRSA was the most common pathogen in sepsis with complication. 6) The mortality rate was 7.4%. 7) There were differences in monthly blood stream infection/1,000 patient-days. Conclusion : The studies about the factors that can influence neonatal sepsis will contribute to decrease the infection rates in NICUs.

Improvement of Fontan Circulatory Failure after Conversion to Total Cavopulmonary Connection (완전 대정맥-폐동맥 연결수술로 전환 후의 폰탄순환장애 개선)

  • Han Ki Park;Gijong Yi;Suk Won Song;Sak Lee;Bum Koo Cho;Young hwan Park
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.559-565
    • /
    • 2003
  • By improving the flow pattern in Fontan circuit, total cavopulmonary connection (TCPC) could result in a better outcome than atriopulmonary connection Fontan operation. For the patients with impaired hemodynamics after atriopulmonary Fontan connection, conversion to TCPC can be expected to bring hemodynamic and functional improvement. We studied the results of the revision of the previous Fontan connection to TCPC in patients with failed Fontan circulation. Material and method: From October1979 to June 2002, eight patients who had failed Fontan circulation, underwent revision of previous Fontan operation to TCPC at Yonsei University Hospital. Intracardiac anomalies of the patients were tricuspid atresia (n=4) and other functional single ventricles (n=4). Mean age at TCPC conversion was 14.0$\pm$7.0 years (range, 4.6~26.2 years) and median interval between initial Fontan operation and TCPC was 7.5 years (range, 2.4~14.3 years). All patients had various degree of symptoms and signs of right heart failure. NYHA functional class was 111 or IV in six patients. Paroxysmal atrial fibrillation (n:f), cyanosis (n=2), intraatrial thrombi (n=2), and protein losing enteropathy (PLE) (n=3) were also combined. The previous Fontan operation was revised to extracardiac conduit placement (n=7) and intraatrial lateral tunnel (n=1). Result: There was no operative death. Major morbidities included deep sternal infection (n=1), prolonged pleural effusion over two weeks (n=1), and temporary junctional lachyarrhythrnia (n=1). Postoperative central venous Pressure was lower than the preoperative value (17.9$\pm$3.5 vs. 14.9$\pm$1.0, p=0.049). Follow-up was complete in all patients and extended to 50,1 months (mean, 30.3$\pm$ 12.8 months). There was no late death. All patients were in NYHA class 1 or 11. Paroxysmal supraventricular tachycardia developed in a patient who underwent conversion to intraatrial lateral tunnel procedure, PLE was recurred in two patients among three patients who had had PLE before the convertsion. There was no newly developed PLE. Conclusion: Hemodynamic and functional improvement could be expected for the patients with Fontan circulatory failure after atriopulmonary connection by revision of their previous circulation to TCPC. The conversion could be performed with low risk of morbidity and mortality.

A Retrospective Analysis of Characteristics of Probiotics Associated with Invasive Bacterial Infections in Children (소아청소년에서 발생한 유산균 제제에 포함된 균주에 의한 침습성 감염증의 후향적 분석)

  • Koh, June Young;Seo, Euri;Lee, Jina
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.3
    • /
    • pp.168-177
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the clinical features and risk factors of invasive infections caused by Lactobacillus spp. and Saccharomyces spp., components of commercially available probiotics. Methods: We analyzed demographic and clinical data from children ${\leq}18$ years of age with an invasive infection caused by Lactobacillus spp. or Saccharomyces spp. at the Asan Medical Center Children's Hospital from January 1998 to June 2016. Probiotic consumption data were also analyzed. Results: During the study period, a total of 24 episodes of invasive infections were caused by Lactobacillus spp. (n=16) and Saccharomyces cerevisiae (n=8). Along with the increase of probiotic use (755,594 [days/1,000 patient-admission days] in 2001 to 2005, 1,444,066 in 2006 to 2010, and 6,904,736 in 2011 to 2016), the incidence of probiotic-associated invasive infection increased ($R^2=0.70$). The median age of the patients was 1.8 years (range, 2 months to 17 years), and most of them had underlying medical conditions. The 30-day mortality rate was 20.8% (5/24), and 11 (45.8%) of these patients resulted from a severe invasive infection. We determined the risk factors for invasive infection to be: previous intensive care unit stay (odds ratio [OR], 3.0; 95% confidence interval [CI], 1.5 to 6.1] and the presence of a central venous catheter (OR, 2.2; 95% CI, 1.2 to 4.3). Conclusions: Although the probiotic-associated invasive infections rarely occurred in children, the incidence has increased along with probiotic pressure. Judicious use of probiotics is mandatory, especially in young children with underlying medical conditions and continuous surveillance will be needed to minimize the safety concerns.

Systemic Candida Infection in Very Low Birth Weight Infants : Epidemiological Features Over 5 Years (극소 저체중 출생아에서 전신성 칸디다 감염 : 5년간의 역학적 특성)

  • Lee, Seung-Woo;Lee, Jeong-Eun;Lee, Ju-Young;Lee, Hyun-Seung;Lee, Jung-Hyun;Sung, In-Kyung
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.190-196
    • /
    • 2009
  • Purpose: Candida infection has increased in neonatal intensive care units (NICU). However, recent reports on systemic candida infections in preterm newborns are rare in Korea. The aim of this study was to examine the epidemiological features of systemic candida infection in very low birth weight infants (VLBW) over the past five years. Methods: We retrospectively reviewed the medical records of 19 patients with systemic candida infections in VLBW that were admitted to the neonatal intensive care units of three hospitals affiliated with the College of Medicine, The Catholic University of Korea from January 2004 to December 2008. We analyzed the birth weight, gestational age, age at diagnosis, risk factors, co-morbidity, antifungal treatment, and mortality rates among the 19 patients. Results: Systemic candida infections occurred in 19 cases (4.7%) among the VLBW infants. The mean birth weight and gestational age were 959.0$\pm$255.9 g and 26.7$\pm$2.1 weeks. The isolated Candida species were C. albicans (4), C. parapsilosis (9), C. glabrata (2), C. famata (2), and unkown subspecies (2). Most patients had various associated risk factors, including a central venous catheter, broad spectrum antibiotics, parenteral nutrition, intravenous lipid emulsion, endotracheal intubation and $H_2$ blocker therapy. There was no significant difference in the risk factors between newborns that survived and those that died with regard to the systemic candida infection, except for gestational age. Nine (47.4%) out of 19 patients with a candida infection died and four cases (21.2%) were directly related to the candida infection. Conclusion: The prevalence of systemic candida infection is increasing in VLBW infants. The majority of Candida species has shifted to C. non-albicans, especially C. parapsilosis. Because of the high mortality associated with candida infection in the NICU, prophylaxis and early treatment based on epidemiological features is necessary.

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

Effects of Modified Ultrafiltration in Pediatric Open Heart Surgery (소아 개심술에 있어서 변형초여과법의 효과)

  • 전태국;박표원
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.591-597
    • /
    • 1997
  • Cardiopulmonary bypass in children is associated with capillary leak which results in an increase in total body water after open heart surgery The purpose of these studies was to assess the cardiopulmonary effects of modified ultrafiltration after pediatric open heart surgery Study h: Twenty-six consecutive children aged 0.1 ~ 10 years(median 7 months) underwent cardiac operation inc rporating modified ultrafiltration. After completion of cardiopulmonary bypass, modified ultrafiltration was commenced at the flow rate of 100~ 15011min for 3 ~ 14 min. After modified ultrafiltration, elevation of hematocrit(28.3% $\pm$ 3.6% vs. 33.8olo $\pm$ 4.Ooloi p < 0.001), increased systolic 1)loots Pressure(66.7 $\pm$ 11.2mmHg vs. 76.2$\pm$ 11.BmmHg, p < 0.02), and decreased central venous pressure(7.8 $\pm$ 3.7mmHg vs. 6.9$\pm$ 2.gmmHg, p<0.001) were observed. Study B: Twenty-six children who underwent cardiac operation with the diagnosis of VSD under 2 years were assigned to control(n= 14) or modified ultrafiltration(n= 12). Peak inspiratory pressure checked immediately after operation was significantly lower in modified ultrafiltration group than in control group(20.0$\pm$ 2.4 cmH20 vs.22.4$\pm$ 2.3cmH20, p < 0.03). Modified ultrafiltration after cardiopillmonary bypass in children improves early homodynamics and pulmonary mechanics, and represents an excellent option for perioperative managemen of accumulation of fluid in the tissues. We will continually employ the modified ultrafiltration technique in pediatric cardiac operations.

  • PDF

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.