• 제목/요약/키워드: Central supply

검색결과 430건 처리시간 0.031초

중앙냉방시스템의 실시간 준최적제어 적용에 따른 실험적 연구 (Real Time Near Optimal Control Application Strategy of Central Cooling System)

  • 안병천;송재엽;주영덕;김진
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.470-477
    • /
    • 2008
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling control system.

실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구 (A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

Effect of Limited Oxygen Supply on Coenzyme $Q_{10}$ Production and Its Relation to Limited Electron Transfer and Oxidative Stress in Rhizobium radiobacter T6102

  • Seo, Myung-Ji;Kim, Soon-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권2호
    • /
    • pp.346-349
    • /
    • 2010
  • Coenzyme $Q_{10}$ ($CoQ_{10}$) production from Rhizobium radiobacter T6102 was monitored under various oxygen supply conditions by controlling the agitation speeds, aeration rates, and dissolved oxygen levels. As the results, the $CoQ_{10}$ production was enhanced by limited oxygen supply. To investigate whether the $CoQ_{10}$ production is associated with its physiological functions of electron carrier and antioxidant, the effects of sodium azide and hydrogen peroxide on the $CoQ_{10}$ production were studied, showing that the $CoQ_{10}$ contents were slightly enhanced with increasing sodium azide (up to 0.4 mM) and hydrogen peroxide (up to $10\;{\mu}M$) concentrations. These results suggest the plausible mechanism where the limited electron transfer stimulating the environments of limited oxygen supply and oxidative stress could accumulate the $CoQ_{10}$, providing the relationship between the $CoQ_{10}$ physiological functions and its regulation system.

모니터 기능을 갖는 통신기기용 전원 시스템 (Power supply system of the telecommunication equipment with monitoring function)

  • 이중기;김영태;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF

디젤발전기 엔진 상태 진단 기술의 발전소 적용 연구 (A Study on the Power Plant Application of Engine Condition Diagnosis Technology for Diesel Generator)

  • 최광희;이상국
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel generator of nuclear power plant has a role for supply of emergency electric power to protect reactor core system in event of loss of off-site power supply. Therefore diesel generator should be tested periodically to verify the function that can supply specified frequency and voltage at design power level within limited time. For this purpose, appropriate maintenances in case that abnormal conditions were found are required in allowed time. In this paper, results of development of engine condition diagnosis technology and study on power plant of its technology for diesel generator are described.

임대아파트 난방방식별 에너지소비와 만족도 조사에 관한 연구 (A Study on the Energy Consumption and the Degree of Satisfaction by Heating System in Rental Apartment)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of homeless housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the energy policy for low-income dwellers, this study investigated the energy consumption and the degree of heating satisfaction by heating system through questionaries in permanent rental apartment and 50 year period rental apartment complexes. The results of this study were as follows; The annual energy consumption of heating and hot water supply is 267.2 Mca1/$\textrm{m}^2$ㆍyr in central heating system, is 163.9 Mca1/$\textrm{m}^2$ㆍyr in unit heating system. But from the view of annual energy cost and the degree of heating satisfaction, central heating system were better than unit heating system in rental apartment.

냉방시스템의 운전조건에 따른 에너지 소비특성 연구 (The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System)

  • 박기태;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

열원 및 공조설비 통합 최적제어기법 구현에 관한 연구 (Real Time Near Optimal Control Application Strategy for Heat Source and HVAC System)

  • 송재엽;안병천;주영덕;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.60-65
    • /
    • 2008
  • The near-optimal control algorithm for central cooling and heating system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled or hot water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling and heating control system.

  • PDF

외장형 MDEC을 이용한 CMS 개발 (The Development of the CMS using External MDEC)

  • 정현철;김태군;강동원;장덕형;유재영;진호;김홍삼;박명철
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2016년도 제53차 동계학술대회논문집 24권1호
    • /
    • pp.335-336
    • /
    • 2016
  • 본 논문에서는 다중 의료장비의 신호를 전송할 수 있는 MDEC과 연동성이 있는 CMS를 개발한다. 주요장비는 환자 감시를 위한 M20과 진단용 심전계 장비인 E40이 대상이 된다. 본 도구는 MDEC의 실효성을 입증하고 환자의 상태를 중앙 집중식으로 모니터링하기 위한 목적으로 개발한다. 먼저, CMS의 기능 구성을 정의하고 MDEC과의 연동성을 위한 프로토콜 정의를 통하여 실제 모니터링 도구를 개발하였다. 향후, 개발된 도구는 CMCIS(Central Monitoring and Cardiology Information System) 기반의 통합 시스템에 적용할 계획이다.

  • PDF

멸균품의 유효기간에 관한 연구 - 포장재와 보관환경 중심으로 - (A Study for Safe Storage Time for In-house Sterilized Products in a Korean Hospital)

  • 윤계숙;김정희;양신해;채지연;이영미;조경숙
    • 한국의료질향상학회지
    • /
    • 제5권2호
    • /
    • pp.258-276
    • /
    • 1998
  • This study was conducted to justify the "prescribed shelf life" currently used in Samsung Medical Center and give recommendations based on scientific data to adopt for safe and cost-effective storage times for sterile goods Since the early 1970's, predetermined expiration dating policy has been used in Korea on all in-house sterilized products like any other countries; six months for the supplies wrapped in polyethylene peel pouches and two weeks for the rest. Recently, however, the studies suggest that current standards for preserving the sterility can be changing. It looks like we unnecessarily have too-short expiration date of sterilized supplies, that is far from being cost effective. Certainly, this research is an exciting project, especially in Korea, and will be leading and contributing to the paradigm shift of the conservative concept of shelf life for sterile supplies in Korean healthcare facilities. The major goal of this study was placed on the measurement of the recontamination time in packs wrapped in all kinds of wrapping materials used in S.M.C and stored in various conditions for periods ranging from three months to six months, and then develop a practical standard of "shelf life" based on the analyzed data. Objectives: To measure and compare the recontamination time of sterile packs among wrapppers and storage conditions, and develop a practical standard for the shelf life and storage conditions of sterile products. Samples and Method: The sterile integrity was investigated of the total 1,440 sterile sample packs containing gauze strip($1.5cm{\times}0.5cm$) we prepared and wrapped in nine wrapping materials (randomized reprocessed linens, linens reprocessed 99 times, linens reprocessed 120 times, new kraft paper, used kraft paper, new nonwoven fabrics, 6-time reprocessed nonwoven fabrics, new polyethylene peel pouches, used polyethylene peel pouches), and stored in four locations(closed cabinet of one of the typical wards, open shelf of one of ICUs, open shelf of separate storage room in ER, open shelf in OR), for three to six months, respectively in 1998. Each type of packs were opened weekly and the gauze strips inoculated into Brewer's thioglycollate broth at $35^{\circ}C$ for seven days. Results: There was no growth found for any types of the pack and storage conditions studied. Discussion: This study was conducted in an attempt to identify the possibility of extending the current shelf life for sterile goods we use in a sense of cost effectiveness. The findings suggest that we could extend our expiration dates, that means we can save a lot of materials and personnel time meeded for resterilizing, outdating, recleaning, wrapping, and reshelving. Then it will initiate a great reform in the field of healthcare in Korea, and now we are looking forward to this valuable revolution. We are going to continue this study and take all steps need to apply this new concept to our practice, and then trying to extend to other hospitals.

  • PDF