• Title/Summary/Keyword: Central pressure

Search Result 931, Processing Time 0.027 seconds

Analytical solution for steady seepage and groundwater inflow into an underwater tunnel

  • Zou, Jin-feng;Wei, An;Liang, Li
    • Geomechanics and Engineering
    • /
    • v.20 no.3
    • /
    • pp.267-273
    • /
    • 2020
  • Solutions of the water pressure and groundwater inflow distribution along the tunnel perimeter in a half-infinite aquifer were investigated considering the conditions of the constant head and constant water pressure. It is assumed that the circular tunnel is buried in a fully saturated, homogeneous, isotropic and half-infinite space. Coordinate transformation technique was adopted, the problem of solving the control equations of water pressure in the Cartesian coordinate was transformed to that in the bipolar coordinate system, which can significantly simplify the derivation procedure of the water pressure and inflow distribution. The validation results show the accuracy and advantage of the proposed approach.

Hemodynamic effects of induced overtransfusion of blood in dogs (과량수혈이 혈역학에 미치는 영향)

  • 기노석
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

The Role of Corporate Social Responsibility on the Relationship of Competitive Pressure and Business Performance of Batik Industry in Central Java, Indonesia

  • SOEWARNO, Noorlailie;TJAHJADI, Bambang;FITRIYAH, Mawar
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.863-871
    • /
    • 2021
  • This study aims to document empirically the mediating role of corporate social responsibility (CSR) on the influence of competitive pressure toward business performance on the batik industry in Central Java, Indonesia. This study also examined the effect of competitive pressure and CSR on business performance of small- and medium-sized enterprises (SMEs) in the batik industry in Central Java. This study used an explanatory quantitative approach. Samples of 254 MSEs in the batik industry have been successfully collected. Hypothesis testing uses SEM-PLS. The results of this study indicate that competitive pressure has a positive and significant effect on the batik MSEs business performance in Central Java. Competitive pressure also has positive direct effect on corporate social responsibility, and CSR has a significant and positive direct effect on business performance. The results of this study have successfully documented empirically that CSR has a mediating role on the relationship of competitive pressure toward business performance in the batik MSEs in Central Java, Indonesia. This study provides a comprehensive understanding of the owners of the batik MSMEs in coping with competitive pressure by using CSR as a strategy to create uniqueness that is difficult to imitate and can create an organizational reputation that eventually can increase business performance.

Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea (한국인 20세부터 24세까지 각막 두께와 안압의 분석)

  • Douk Hoon Kim;Kishor Sapkota
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

An improved model of compaction grouting considering three-dimensional shearing failure and its engineering application

  • Li, Liang;Xiang, Zhou-Chen;Zou, Jin-Feng;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.19 no.3
    • /
    • pp.217-227
    • /
    • 2019
  • This study focuses on an improved prediction model to determine the limiting grouting pressure of compaction grouting considering the ground surface upheaval, which is caused by the three-dimensional conical shearing failure. The 2D-dimensional failure curve in Zou and Xia (2016) was improved to a three-dimensional conical shearing failure for compaction grouting through coordinate rotation. The process of compaction grouting was considered as the cavity expansion in infinite Mohr-Coulomb (M-C) soil mass. The prediction model of limiting grouting pressure of compaction grouting was proposed with limit equilibrium principle, which was validated by comparing the results in El-Kelesh et al. (2001) and numerical method. Furthermore, using the proposed prediction model, the vertical and horizontal grouting tube techniques were adopted to deal with the subgrade settlement in Shao-huai highway at Hunan Provence of China. The engineering applicability and effectiveness of the proposed model were verified by the field test. The research on the prediction model for the limiting grouting pressure of compaction grouting provides practical example to the rapid treatment technology of subgrade settlement.

Analysis of Cavity Pressure and Dimension of Molded Part According to V/P Switchover Position in Injection Molding

  • Cho, Jung Hwan;Kwon, Soon Yong;Roh, Hyung Jin;Cho, Sung Hwan;Kim, Su Yeon;Lyu, Min-Young
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.309-316
    • /
    • 2017
  • In injection molding, the quality of an injection molded product varies greatly depending on the molding conditions. Many researche studies have been conducted on the quality analysis of molded parts according to the molding conditions such as injection pressure, injection temperature, and packing pressure. However, there have not been many studies on the V/P switchover timing. It is known that when a large pressure is applied to a cavity in the packing phase, the cavity pressure is most affected by the packing pressure. In addition, depending on the position (timing) of the packing pressure, it can have a direct influence on quality based on the shrinkage and dimensions of the molded parts. In this study, the change in pressure profile in the cavity according to the V/P switchover position is confirmed. A CAE analysis program (Moldflow) was used to simulate and analyze two models using the PC and PBT materials. In order to compare these results with the actual injection molding results, injection molding was performed for each V/P switchover position, and the correlation between simulation and experiment, especially for the shrinkage of molded parts, was evaluated.

CFD based simulations of flutter characteristics of ideal thin plates with and without central slot

  • Zhu, Zhi-Wen;Chen, Zheng-Qing;Gu, Ming
    • Wind and Structures
    • /
    • v.12 no.1
    • /
    • pp.1-19
    • /
    • 2009
  • In this paper, the airflow around an ideal thin plate (hereafter referred to as ITP) with various ratios of central slot is simulated by using the finite-difference-method (FDM)-based Arbitrary-Lagrangian-Eulerian descriptions for the rigid oscillating body. The numerical procedure employs the second-order projection scheme to decouple the governing equations, and the multigrid algorithm with three levels to improve the computational efficiency in evaluating of the pressure equation. The present CFD method is validated through comparing the computed flutter derivatives of the ITP without slot to Theodorsen analytical solutions. Then, the unsteady aerodynamics of the ITP with and without central slot is investigated. It is found that even a smaller ratio of central slot of the ITP has notable effects on pressure distributions of the downstream section, and the pressure distributions on the downstream section will further be significantly affected by the slot ratio and the reduced wind speeds. Continuous increase of $A_2^*$ with the increase of central slot may be the key feature of the slotted ITP. Finally, flutter analyses based on the flutter derivatives of the slotted ITP are performed, and moreover, flutter instabilities of a scaled sectional model of a twin-deck bridge with various ratios of deck slot are investigated. The results confirm that the central slot is effective to improve bridge flutter stabilities, and that the flutter critical wind speeds increase with the increase of slot ratio.

The characteristics of subgrade mud pumping under various water level conditions

  • Ding, Yu;Jia, Yu;Wang, Xuan;Zhang, Jiasheng;Luo, Hao;Zhang, Yu;Chen, Xiaobin
    • Geomechanics and Engineering
    • /
    • v.30 no.2
    • /
    • pp.201-210
    • /
    • 2022
  • This paper presents a study regarding the influence of various water levels on the characteristics of subgrade mud pumping through a self-developed test instrument. The characteristics of mud pumping are primarily reflected by axial strain, excess pore water pressure, and fine particle migration. The results show that the axial strain increases nonlinearly with an increase in cycles number; however, the increasing rate gradually decreases, thus, an empirical model for calculating the axial strain of the samples is presented. The excess pore water pressure increases rapidly first and then decreases slowly with an increase in cycles number. Furthermore, the dynamic stress within the soil first rapidly decreases and then eventually slows. The results indicate that the axial strain, excess pore water pressure, and the height and weight of the migrated fine particles decrease significantly with a low water level. In this study, when the water level is 50 mm lower than the subgrade soil surface, the issue of subgrade mud pumping no longer exist.

Various Factors Influencing Thoracic Duct Lymph Flow in the Dogs (임파유통에 영향을 주는 인자에 관한 실험적 연구)

  • Kim, Ki-Whan;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 1975
  • Various factors influencing the lymph flow from thoracic duct were investigated in an attempt to evaluate their contributing degree and the mechanisms. Sixteen mongrel dogs weighing between 10 and 16 kg were anesthetized and polyethylene catheters were inserted into the thoracic duct and femoral veins. Arterial blood pressure, heart rate, central venous pressure, lymph pressure and lymph flow were measured under various conditions. Electrical stimulation of left sciatic nerve, stepwise increase of central venous pressure, manual application of rhythmical depressions onto abdomen, injection of hypertonic saline solution and histamine infusion were employed. Measurement of cental venous pressure was performed through the recording catheter inserted into abdominal inferior vena cava. Changes in central venous pressure were made by an air-ballooning catheter located higher than the tip of the recording catheter in the inferior vena cava. Lymph flow from thoracic duct was measured directly with a graduated centrifuge tube allowing the lymph to flow freely outward through the inserted cannula. The average side pressure of thoracic lymph was $1.1\;cmH_2O$ and lymph flow was 0.40 ml/min or 1.9 ml/kg-hr. Hemodynamic parameters including lymph flow were measure immediately before and after (or during) applying a condition. Stimulation of left sciatic nerve with a square wave (5/sec, 2 msec, 10V) caused the lymph flow to increase 1.4 times. The pattern of lymph flow from thoracic duct was not continuous throughout the respiratory cycle, but was continuous only during Inspiration. Slow and deep respiration appeared to increase the lymph flow than a rapid and shallow respiration. Relationship between central venous pressure and the lymph flow revealed a relatively direct proportionality; Regression equation was Lymph Flow (ml/kg-hr)=0.09 CVP$(cmH_2O)$+0.55, r=0.67. Manual depressions onto the abdomen in accordance with the respiratory cycle caused the lymph flow to increase most remarkably, e.g,. 5.5 times. The application of manual depressions showed a fluctuation of central venous pressure superimposed on the respiratory fluctuation. Hypertonic saline solution (2% NaCl) administered Intravenously by the amount of 10 m1/kg increased the lymph flow 4.6 times. The injection also increased arterial blood pressure, especially systolic Pressure, and the central venous pressure. Slow intravenous infusion of histamine with a rate of 14-32 ${\mu}g/min$ resulted in a remarkable increase in the lymph flow (4.7 times), in spite of much decrease in the blood pressure and a slight decrease in the central venous pressure.

  • PDF

Acute Cardiac Tamponade, Report of 6 Cases (각종 원인에 의한 급성 Cardiac Tamponade: 6례 보고)

  • 조장환;이명진;홍승록
    • Journal of Chest Surgery
    • /
    • v.5 no.2
    • /
    • pp.97-106
    • /
    • 1972
  • We will report 6 cases of cardiac tamponade treated surgically at Severance Hospital during the past 9 years from 1964 to 1972 and reviewed literatures on cardiac tamponade. The age of patients was from 13 years to 45 years old. The male was 4 cases and the female 2 cases. The sites of injury were right atrium; 1 case, right ventricle; 2 cases, right ventricle and coronary artery; 1 case, left atrium; 1 case, and left ventricle; 1 case. 2 cases of cardiac tamponade developed following chest injury, 2 cases following pericardiocentesis,1 case due to continuous bleeding from sutured cardiotomy wound of left atrium following open mitral commissurotomy using cardiopulmonary bypass machine, and 1 case due to traumatic penetration of polyethylene catheter through right ventricle to pericardial sac, introduced via right jugular vein in order to monitor the central venous pressure. Central venous pressure was checked preoperatlvely in 5 cases. In all cases, central venous pressure was rised [the range of central venous pressure was 240 to 330 mmHg]. Immediately after operation,central venous pressure lowered to normal [the range was 80-100 mmHg]. Recently serial gas analysis of arterial blood were checked pre- and post-operatively for the evaluation of hemodynamic change of cardiac tamponade, but our data was not enough for evaluation. It should be studied further.

  • PDF