• 제목/요약/키워드: Central heating system

검색결과 100건 처리시간 0.025초

기획특집 - 초고층 설비설계사례 (HVAC System For Highriser Residential Bilding)

  • 노석남
    • 기술사
    • /
    • 제42권5호
    • /
    • pp.32-36
    • /
    • 2009
  • This project located in IFEZ(Incheon Free Economic Zone) is the first central heating and cooling type for high-rise residential building in korea. The design was performed as the joint venture between Cosentini from U.S.A and wooowon, and our design concept was to save energy. LEED application from USGBC is going on in progress for the first residential building in korea. Careful attention was paid from schematic design for not a durability of structural and architectural, but also durability and safety of M.E.P.

  • PDF

Y 스트레이너형 자동 정유량 조절 밸브의 개발 (Development of Y Strainer Type Automatic Flow Rate Regulating Valve)

  • 윤준용;권우철
    • 한국유체기계학회 논문집
    • /
    • 제10권1호
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구 (A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems)

  • 강희정;이현수;장명훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2018
  • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.

변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가 (Ventilation and energy performance evaluation of the office building with variable air volume system)

  • 권용일;권순석
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF

Fuzzy-Neuro Controller for Control of Air-Conditioning System

  • Lee, Sang-Bae
    • 한국지능시스템학회논문지
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 1995
  • A practical application of a fuzzy-neuro controller is described for an air-conditioning system. Air-handing units are being widely used for improving the performance of central air-conditioning systems. The fuzzy-neuro control system has two controlled variables, temperature and humidity and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical contorl, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy-neuro control system is described for controlling air-conditioning systems efficiently and economically. Simulation results confirmed that the fuzzy neuro control system is effective for this multivariable system.

  • PDF

에어콘의 효과적인 퍼지 제어 시스템의 설계 (The Design of Efficient Fuzzy Logic Control System for Air-Conditioner)

  • 김일;이상배;이철영
    • 한국항해학회지
    • /
    • 제18권4호
    • /
    • pp.147-154
    • /
    • 1994
  • A practical application of a fuzzy control system is described for an air-conditioning system. Air-hadling units are being widely used for improving the performance of central air-conditioning systems. The fuzzy control system has two controlled variables, temperature and humidity, and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical control, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy control system was described for controlling air-conditioning systems efficiently and economically.

  • PDF

부산지역 대형병원 냉방장비의 용량설정 실태조사 (Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

가스 다이내믹 점화기의 온도상승 지배인자에 관한 수치적 연구 (Numerical Investigation about the Dominating Factors of Heat Increasing in a Gas-Dynamic igniter)

  • 이재원;최효상;임대홍;서성현;강상훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.734-738
    • /
    • 2017
  • 본 연구에서는 가스다이내믹 공진 점화시스템 (Gas-dynamic Ignition System)의 온도상승 지배인자를 파악하고, 공진관으로의 질량유입 패턴의 영향에 대해 연구하였다. OpenFOAM 프로그램을 이용하여 세 가지 Case에 대한 전산해석을 수행하였으며, RhoCentralFoam을 적용하였다. 해석결과로, 작동유체의 가열이 공기열역학적 현상에 의한 것임을 밝히고, 공진관으로의 원활한 질량유입이 온도 상승에 중요한 지배인자임을 확인하였다.

  • PDF

건축물 냉.난방 시스템에 따른 에너지 소비 특성 -서울 소재 A 대학교 건축물을 중심으로- (The Energy Consumption Characteristics of Building Accordance with Air-Conditioning and Heating System)

  • 박강현;차정훈;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.333-337
    • /
    • 2011
  • Central control air-conditioning systems are being replaced with individually controlled air-conditioning system in the university. The amount of growth of electricity consumption is due to the increasing demand of electric heat pump. In winter and summer, the energy consumption showed a tendency to increase. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because electric heat pump, gas driven heat pump and the absorption chiller-heater are used at the same time in some of the buildings.

  • PDF