• Title/Summary/Keyword: Central control system

Search Result 996, Processing Time 0.033 seconds

An Innovative Expert System for the Maintenance of On-site Wastewater Treatment Process for Small-scale Residential and Commercial Sites (마을단위 소규모 하·폐수처리 공정의 효율적 유지관리를 위한 전문가 시스템에 관한 연구)

  • Kim, Seung-jun;Choi, Yong-su;Hong, Seok-won;Kwon, Gi-han;Chung, Ik-jae
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.132-140
    • /
    • 2005
  • The pilot test of a new alternative for small wastewater treatment system has been conducted for two years. It consists of a hybrid bioreactor and the expert system including the process control logic, PLC system, and HMI for the process automation. In order to monitor and remote control its status, the real-time data was transferred from the on-site control center to the central station via a wireless local area network. More efficient and stable performances were observed at automatic operating mode compared with the manual. On an average, COD, SS, T-N and T-P concentrations in the effluent from the hybrid bioreactor were less than 14, 7, 12 and 0.9 mg/L, respectively. According to the result from pilot tests, the quality of treated wastewater with sand filtration was enough to be utilized again.

A Study on Smart Road Stud System with RF Wireless Control (RF 방식의 무선 제어 기능을 내장한 스마트 도로 표지병 시스템에 대한 연구)

  • Kim, Hyung-Sik;Jeon, Joon-Hyeok;Kim, Hee-Jun;Ahn, Joon-Seon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.282-289
    • /
    • 2019
  • Reflective and solar LED road studs are being used as a way of securing visibility for road environments. Road markers have various advantages and disadvantages in terms of versatility, efficiency, simplicity and visibility as individual products of reflective type and solar LED. However, in addition to the above, it is possible to prevent secondary accident after accident, It has a common drawback that it is difficult to have. In this paper, we propose a road stud system incorporating a wireless control function using RF - based communication with existing solar LED road studs and a system for controlling them. The proposed system is called the smart road stud system and it can control the equipment through the central control unit and the relay unit connected to the central control room by incorporating the RF communication function in the existing solar LED road stud. In addition, since it is possible to control the lighting method, color, etc. according to the road condition, it is possible to provide the driver with the state of the road to perform the function for preventing the second accident after the accident. It also adds features that minimize the ongoing power consumption of LED and RF communications. In order to verify the validity of the proposed system, prototypes were produced and it was confirmed that it is possible to act as a university for prevention of accident after accident by linking with other traffic system besides accident prevention function by securing existing visibility.

A study on real-time communication of remote station in the distributed control system (분산 제어 시스템에서 원격 제어국의 실시간 통신에 관한 연구)

  • 김내진;김진태;박인갑
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.21-30
    • /
    • 1994
  • We discussed the Distributed Control System's design on preface and analyzed time of the real-time communication by using designed system. The DCS proposed in this thesis was implemented to network file system having recovery advantage and shared memory method to access file system of a Remote Station with ease. Also, this system minimized the network delay-time by using the real-time VME147 board. In implemented DCS, the performance analysis of real-time process of a Remote Station was done to get the total time for reak-tune communication from a Remote Station to the Central Station after terminating of process. For the analysis of system performance, we experiented by three steps. Firstly, we measuredthe processing the of LOOP function that real-time CPU convertes to-2,500~10.000 values from the input data of the Analog Interface Card. Secondly, we measured the processing time of the LOGIC function and the LOOP function. Lastly, we measured total processing time for communication from a Remote Station to the Centrol Station.

  • PDF

A Study on Improvement of Local Government Disaster Management System in Korea - Focused on Strengthening the Disaster Management Capacity of Local Government - (지방자치단체 재난관리체계 개선에 관한 연구 - 지방자치단체의 재난관리 역할 강화를 중심으로 -)

  • Hong, Ji-Wan
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.21-30
    • /
    • 2018
  • This study aims for improving the system in Disaster Management of Local Government. In addition, the overall disaster management system was compared to the effectiveness of the disaster prevention system and reliability, and problems and improvement points were derived. The disaster management system in Korea has a structure that promptly investigates and restores damage by a simple procedure. Korea disaster management system manages information on top-down structural disasters through the flow of prevention, preparation, response, and recovery. The process from disaster response to recovery under the leadership of the central disaster safety headquarters is simplified. Disaster management tasks are dispersed among departments, making it difficult to respond promptly. Under the control of the central government, disaster management, such as disaster prevention, investigation, and recovery, are carried out. The disaster management improvement direction of the local government should establish the disaster response system focusing on the local government. Therefore, it is necessary to have budget to operate the organization - centered disaster management budget and the disaster management organization. The disaster response manual should be prepared considering the disaster environment and disaster prevention plan. In order to utilize disaster information, it is necessary to reorganize information system such as integrate and streamline of the private resource database and NDMS.

Influence of Joint Mobilization on Formalin Induced Pain Prevention of Rats (관절가동술이 흰쥐의 포르말린 유도 통증 예방에 미치는 영향)

  • Kang, Jong-Ho;Kim, Eun-Kyung;Ro, Hyo-Lyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.2
    • /
    • pp.207-213
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the preventive effect of joint mobilization on biphasic pain response induced formalin test. Methods: Sprague-dawley rats(n=30) were ramdomly divided into the control group without intervention, sham control group with application of hand contact without mobilization, joint mobilization group with application of hand contact with mobilization. Joint mobilization of knee procedure involved an grade III extension mobilization basically with anterior-posterior gliding of the tibia on the femur. Formalin injection caused biphasic pain response which is lated for 60 minute. The first phase result from primary afferent sensory fiber, wheareas the second phase has been proposed to central sensitization in the central nervous system. Behavioral analysis was performed by digital camera after 5% formalin subcutaneous injection into the dorsal foot. Results: Pain response of joint mobilization group show significant lower than control gorup and sham control group. Conclusion: This result suggest that pre-application of joint mobilization may be effective intervention to prevent the formalin induced pain.

Fault Tolerant Control of Sensor Fault of EPB System (EPB 시스템의 센서 고장 허용 제어 기법)

  • Lee, Won-Goo;Lee, Young-Ok;Jang, Min-Seok;Lee, Choong-Woo;Chung, Chung-Choo;Chung, Han-Byul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.8-17
    • /
    • 2010
  • In this paper, a fault tolerant control against sensor faults of electric parking brake (EPB) is proposed. Fault tolerant control method of EPB system is strongly demanded since sensor faults can endanger a driver's safety. In this paper, a clamp force estimation method is presented using motor's armature current and angular velocity. Clamp force estimation method is applied for fault detection method with parity equations. The goal of the detection method is to detect and identify faults in encoder, current sensor, force sensor, and parking cable. And a switching logic for fault tolerant control against the three sensor faults is suggested. Experimental results show that the proposed force estimation method satisfies the specifications of EPB system. The effectiveness of the fault detection method is validated with experimental results. Although a single sensor fault happens, EPB system with the proposed fault detection method does not develop into a failure on subsystem or system level.

Accounting Information System, Internal Control System, Human Resource Competency and Quality of Local Government Financial Statements in Indonesia

  • SUMARYATI, Anna;PRAPTIKA NOVITASARI, Eka;MACHMUDDAH, Zaky
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.795-802
    • /
    • 2020
  • This study seeks to determine the effect of the application of accounting information system (AIS), internal control system, and human resource (HR) competency on the quality of local government financial statements (FS). This study uses agency theory and compliance theory. Agency theory is used to explain that there is a link between the society as the principal and the government as the agent. Compliance theory is a theory, which states that every agency is obliged to comply with regulations because the law-drafting authority has the right to dictate behavior. The population in this study were employees of the financial division of local government organizations in one of the districts in Central Java, Indonesia. The total samples in this study was 106 respondents. The data used are primary data taken from distributing questionnaires to respondents. The method of analysis used to test the hypothesis was multiple linear regression analysis. The results of hypothesis testing indicate that HR competency has an effect on the quality of FS; however, the application of AIS and internal control system has no effect on the quality of FS. The implication of this research underlines the importance of HR competency to improve the quality of local government FS.

Methods for an application of real-time network control on distributed storage facilities (분산형 저류시설의 실시간 네트워크 제어기술 적용시 고려 사항)

  • Beak, Hyunwook;Ryu, Jaena;Oh, Jeill;Kim, Tae-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.711-721
    • /
    • 2013
  • Optimal operation of a combined sewer network with distributed storage facilities aims to use the whole retention capacity of all reservoirs efficiently before overflows take place somewhere in the considered network system. An efficient real-time network control (RTNC) strategy has been emerging as an attractive approach for reducing substantially the overflows from a sewer network compared to the conventional fixed or manually adjusted gate setting method, but the related concrete framework for RTC development has not been throughly introduced so far. The main goal of this study is to give a detailed description of the RTNC systems via reviewing several guidelines published abroad, and finally to suggest methods for the proper application of RTNC on distributed storage facilities. Especially, this study is focused on emphasizing the importance of hierarchical structure of RTNC system that consists of three control layers (management, global control and local control). Further, with regard to the global control layer which is responsible for the central overall network control, the wide-ranging details of two components (adaption and optimization layers) are also presented. This study can provide the valuable basis for the RTNC implementation in the particular sewer network with distributed multiple storage facilities.

Robust control of Nonlinear System Using Multilayer Neural Network (다층 신경회로망을 이용한 비선형 시스템의 견실한 제어)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.4
    • /
    • pp.243-248
    • /
    • 2013
  • In this thesis, we have designed the indirect adaptive controller using Dynamic Neural Units(DNU) for unknown nonlinear systems. Proposed indirect adaptive controller using Dynamic Neural Unit based upon the topology of a reverberating circuit in a neuronal pool of the central nervous system. In this thesis, we present a genetic DNU-control scheme for unknown nonlinear systems. Our method is different from those using supervised learning algorithms, such as the backpropagation (BP) algorithm, that needs training information in each step. The contributions of this thesis are the new approach to constructing neural network architecture and its training.