• 제목/요약/키워드: Central air conditioning system

검색결과 62건 처리시간 0.023초

태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

퍼지 LMS 알고리즘을 이용한 공조덕트에서의 능동소음제어 (Active Control of Noise in HVAC Ducts Using Fuzzy LMS Algorithms)

  • 남현도;안동준;박용식
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.265-272
    • /
    • 1999
  • A LMS algorithms has been widely used for an adaptive filter algorithm in active noise control systems. But this algorithm has poor convergence and it is very difficult to select optimal convergence parameters in this algorithm. In this paper, a fuzzy LMS algorithm where the convergence parameters are computed using a fuzzy logic controller was proposed. A proposed algorithm was applied to active noise control system in HVAC(central Heating Ventilation and Air Conditioning) ducts. The experimental ducts and experimental apparatus were designed and manufactured for experiments, and the modelling of the experimental ducts was also performed for computer simulations. Computer simulations and experiments were performed to show the effectiveness of a proposed algorithm.

  • PDF

공동주택에서의 지역에 따른 건물에너지 효율등급 평가 연구 (A Study on the Evaluation of Building Energy Rating considering the Region of Apartment Houses)

  • 안병립;김치훈;김지연;장철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

  • PDF

중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구 (A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • 제17권3호
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.

Variation of Energy Consumption in Barracks through Simulation by Year of Completion

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong;Yoo, Jeong-Seong
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze & suggest the variation of energy consumption consequent on thermal insulation performance strengthening from early 2000s when modernization of barracks began until the present targeting a large barracks. Method: To carry out this research, this study surveyed the standard of thermal insulation by year, which is being applied to a barracks by conducting literature search, and selected the standard model for a barracks. Also, this study analyzed energy consumption by year & region by performing simulation(ECO2)of the selected standard model. Result: As a result, it was analyzed that in case of a building which was completed in 2015, the energy consumption for air-conditioning & heating, lighting, and hot water supply over the year 2000 reduced by 11% on the average in central district, 10% on the average in southern district, and 17% on the average in Jeju, respectively.

EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가 (Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus)

  • 서정기;위승환;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.655-663
    • /
    • 2016
  • 최근, 전 세계적으로 온실 가스 증가에 따른 기후 변화에 대한 문제가 논의되고 있다. 그중, 건축물에서의 에너지 소비량은 전체 에너지 소비량의 40%까지 증가할 것으로 예상된다. 따라서 건축물에서의 에너지 소비량 절감에 대한 노력이 필요한 실정이다. 본 연구에서는, 건물에너지 절감에 효과적으로 기여하는 재료 중 하나인 목재를 이용하여, 목질 제품 구성에 따른 중부지방과 남부지방의 난방에너지 요구량에 대하여 시뮬레이션을 통해 분석하였다. 시뮬레이션 도구는 미국 에너지부(Department of Energy)가 BLAST와 DOE-2의 장점을 결합해 만든 동적 에너지 해석 엔진인 EnergyPlus를 이용하였다. EnergyPlus는 다양한 건물 및 HVAC 시스템 구성요소(Object)에 대한 입력항목(Field)을 가지고 있으며, 특히 건물, 공조시스템, 열원기기 사이의 피드백을 통해 통합된 동시계산을 수행하며, ASHRAE Standard 140-2007 표준에 따라 상용 프로그램 간의 비교를 통해 검증된 프로그램이다. 시뮬레이션을 위한 기상데이터는 EnergyPlus에서 제공하는 IWEC 인천 지역과 광주 지역의 epw 형식 기상데이터를 이용하였다. 대상 모델은 한국농어촌공사에서 제시한 2012년 농 어촌주택 표준설계도면 중 '농림-12-26-가' 유형을 이용하였으며 총 10개의 실로 구성되어 있다. 시뮬레이션 분석 결과, 중부지방과 남부지방 별 목질 제품의 적용 범위를 실내마감재, 실외마감재, 창호, 목구조로 단계적으로 변경해 지역에 따라 각각 16 Case의 시뮬레이션을 수행한 결과 실내외의 마감재로 목재를 사용한 것만으로도 에너지 성능이 향상된 것을 확인할 수 있었다.

유리섬유 및 알루미늄 금속 혼합물 유리조성 개발 (Development on Glass Formulation for Aluminum Metal and Glass Fiber)

  • 조현제;김천우
    • 방사성폐기물학회지
    • /
    • 제10권4호
    • /
    • pp.247-254
    • /
    • 2012
  • 원전에서 발생되는 방사성폐기물에 대한 고화처리 방법 중 하나인 유리화기술이 일부 가연성폐기물에 대해 적용되고 있다. 국내외적으로 중저준위 방사성폐기물의 효과적인 감용과 안정적인 처분을 위해 다양한 폐기물에 대한 유리화기술 적용방안이 확대 연구되고 있으며, 최근에는 가연성폐기물 뿐만 아니라 알루미늄 금속과 같은 비가연성폐기물에도 유리화 연구가 활발하게 진행되고 있다. 공기조화계통 (HVAC)에는 주로 필터가 이용되고 있으며, 사용 후 필터는 여과재 (유리섬유 및 알루미늄)를 이용하여 배기체를 흡착하기 때문에 방사성폐기물로 처리가 되어야 한다. 본 연구는 필터에 대한 처리기술 연구를 위해 유도가열식 저온용융로 (Cold Crucible Induction Melter: CCIM)를 이용한 유리화 타당성 연구를 수행하였다. 사용후 필터에 대한 유리화 (Vitrification)는 먼저 유리섬유 및 알루미늄 함량을 고려한 최적의 유리조성을 개발 하였으며, 개발된 유리 조성을 이용하여 최적의 폐기물 저감을 위한 용융변수와 최종 생성된 유리고화체의 특성을 분석하였다. 사용후 필터 유리화용 조성유리는 주로 $SiO_2$$B_2O_3$로 구성되어 있다. 전기로를 이용한 용융물 특성시험에서는 폐기물 투입률 및 최종 생성물인 유리고화체의 특성이 검토되었다. 본 연구에서는 알루미늄 금속과 유리섬유로 구성된 필터에 대한 유리조성 개발과 이를 통해 생성된 유리고화체의 물리화학적 특성을 검토하고 유리화 타당성을 확인하였다.

치과위생사의 직무스트레스에 관한 분석요인 (A Factor Analysis on Job Stress Level in Dental Hygienists)

  • 김지화;오나래;정미애
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.1220-1228
    • /
    • 2012
  • 본 연구는 치과위생사가 경험하는 직무 스트레스 정도와 직무만족도 및 상관관계를 파악 하여 치과위생사 직무만족도를 높여 양질의 의료서비스를 제공하고, 치과위생사 개인의 발전과 건강 증진에 필요한 기초자료를 마련하고자 본 연구를 시행하였다. 2011년 8월 1일부터 12일까지 전국(서울, 경기, 대구, 포항)의 종합병원, 치과병원, 치과의원의 치과위생사 210명을 대상으로 자기기입식 설문지 조사를 시행한 후 205명에 대해서 분석 하였다. 수집된 자료는 SPSS WIN 15.0 프로그램을 이용하여 분석하였다. 그 결과 직무스트레스 중에는 평균이 '직무요구'가 2.71로 가장 높게 나타났다. 치과위생사의 빌딩관련 건강자각도와 직무스트레스의 영역별 관계에 대해 살펴본 결과는 중추신경계 증상은 물리환경(r=.281, p<.001)과 직무요구(r=.281, p<.001), 관계갈등(r=.163, p<.05), 조직체계(r=.166, p<.05), 보상 부적절(r=.267, p<.001), 그리고 직무스트레스(r=.311, p<.001)와 통계적으로 유의미한 정적 상관관계를 보였다. 전체적으로 빌딩관련 건강자각도는 물리환경(r=.259, p<.001)과 직무요구(r=.311, p<.001), 관계갈등(r=.172, p<.05), 조직체계(r=.158, p<.05), 보상 부적절(r=.197, p<.01), 그리고 직무스트레스(r=.275, p<.001)와 통계적으로 유의한 상관관계를 보였다. 치과위생사에 대한 근무환경 중 실내공기오염저감 및 스트레스를 예방할 수 있는 근무환경 개선의 기초자료로 활용함으로써 치과위생사의 정신건강 및 삶의 질 향상으로 양질의 의료서비스 제공에 기여할 수 있을 것으로 판단된다.

Model of Water, Energy and Waste Management for Development of Eco-Innovation Park ; A Case Study of Center for Research of Science and Technology "PUSPIPTEK," South Tangerang City, Indonesia

  • Setiawati, Sri;Alikodra, Hadi;Pramudya, Bambang;Dharmawan, Arya Hadi
    • World Technopolis Review
    • /
    • 제3권2호
    • /
    • pp.89-96
    • /
    • 2014
  • Center for Research of Science and Technology ("PUSPIPTEK") has 460 hectares land area, still maintained as a green area with more than 30% green space. There are 47 centers for research and testing technology, technology-based industries, and as well as public supporting facilities in PUSPIPTEK area. Based on the concepts developed to make this area as an ecological region, PUSPIPTEK can be seen as a model of eco-innovation. The purpose of this research is to develop a model of water, energy and waste management with eco-innovation concept. As a new approach in addressing environmental degradation and maintaining the sustainability of ecosystem, studies related to eco-innovation policy that combines the management of water, energy and waste in the region has not been done. In order to achieve the objectives of the research, a series of techniques for collecting data on PUSPIPTEK existing conditions will be carried out, which includes utilities data (water, electricity, sewage) and master plan of this area. The savings over the implementation of the concept of eco-innovation in water, energy, and waste management were calculated and analyzed using quatitative methods. The amount of cost savings and feasibility were then calculated. Eco innovation in water management among other innovations include the provision of alternative sources of water, overflow of rain water and water environments utilization, and use of gravity to replace the pumping function. Eco-innovation in energy management innovations include the use of LED and solar cell for air conditioning. Eco-innovation in waste management includes methods of composting for organic waste management. The research results: (1) The savings that can be achieved with the implementation of eco innovation in the water management is Rp. 3,032,640 daily, or Rp.1,106,913,600 annually; (2) The savings derived from the implementation of eco innovation through replacement of central AC to AC LiBr Solar Powered will be saved Rp.1,933,992,990 annually and the use of LED lights in the Public street lighting PUSPIPTEK saved Rp.163,454,433 annually; (3) Application of eco innovation in waste management will be able to raise awareness of the environment by sorting organic, inorganic and plastic waste. Composting and plastic waste obtained from the sale revenue of Rp. 44,016,000 per year; (4) Overall, implementation of the eco-innovation system in PUSPIPTEK area can saves Rp. 3,248,377,023 per year, compared to the existing system; and (5)The savings are obtained with implementation of eco-innovation is considered as income. Analysis of the feasibility of the implementation of eco-innovation in water, energy, and waste management in PUSPIPTEK give NPV at a 15% discount factor in Rp. 3,895,228,761; 23.20% of IRR and 4.48 years of PBP. Thus the model of eco-innovation in the area PUSPIPTEK is feasible to implement.