• 제목/요약/키워드: Centering ability

검색결과 67건 처리시간 0.025초

Comparison of shaping ability of the Reciproc Blue and One Curve with or without glide path in simulated S-shaped root canals

  • Vincenzo Biasillo;Raffaella Castagnola;Mauro Colangeli;Claudia Panzetta;Irene Minciacchi;Gianluca Plotino;Simone Staffoli;Luca Marigo;Nicola Maria Grande
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.3.1-3.9
    • /
    • 2022
  • Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and Methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

Study of a self-centering beam-column joint with installed tapered steel plate links

  • Liusheng He;Yangchao Ru;Haifeng Bu;Ming Li
    • Structural Engineering and Mechanics
    • /
    • 제87권4호
    • /
    • pp.391-403
    • /
    • 2023
  • In this study, a new type of self-centering beam-column joint with tapered steel plate links is proposed. Firstly, mechanical property of the basic joint (with the prestressed steel strands only, to provide the self-centering ability) and the combined joint (with both the prestressed steel strands and tapered steel plate links, to provide self-centering and energy dissipation simultaneously) is theoretically analyzed. Then, three joints with different dimensions and combinations of tapered plate links are designed and tested through a series of quasi-static cyclic loading tests. Test results show that a nearly bilinear elastic moment-rotation relationship for the basic joint is obtained. With the addition of tapered steel plate links, typical flag-shape hysteretic curves are obtained, which indicates good self-centering and energy dissipating ability of the combined joint. By installing multiple tapered plate links, stiffness and bearing capacity of the beam-column joint can be enhanced. The theoretical moment-rotation relationships agree well with the test results. A simplified macro model of the proposed joint is developed using OpenSees, which simulates reasonably well its hysteretic behavior.

모조 레진블락 근관에서 LightSpeed, ProTaper 및 Hybrid technique의 성형 효율 비교 (Comparison of shaping ability using LightSpeed, ProTaper and Hybrid technique in simulated root canals)

  • 강순일;곽상원;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제47권7호
    • /
    • pp.444-454
    • /
    • 2009
  • The purpose of this study was to compare the shaping abilities of LightSpeed, ProTaper-Universal, and hybrid technique using S-series of ProTaper-Universal and LigthSpeed. The 72 simulated root canals of J-shape were used and classified as flowing 3 groups according to the instrumentation methods; Group P of 24 canal blocks were prepared with ProTaper-Universal, Group L was prepared with LightSpeed, and Group H was prepared with hybrid technique (initial shaping with ProTaper-Universal SI and S2 and apical shaping with LightSpeed from #25 to #50). A second-year resident of Endodontic department prepared the resin block canals to apical size #50 (F5 in Group P). The time lapses for instrumentation and the reduction of root canal curvature after shaping were measured. The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the increased canal width and apical centering ratio. The results were as followings: Group Land H showed significant less instrumentation time than Group P (p < 0.05). The ProTaper system showed greater reduction of root canal curvature and working length diminishment than other methods (p < 0.05). LightSpeed system showed best canal curvature preserving characteristics. The Group P had greater instrumented widths at all levels examined (p < 0.05). Group L and Group H showed lower centering ratio (ability to preserve the canal center; the lower ratio means the better canal center preservation) than Group P (p < 0.05). Group H had the lowest centering ratio at the 1 mm level.

  • PDF

Application of self-centering wall panel with replaceable energy dissipation devices in steel frames

  • Chao, Sisi;Wu, Hanheng;Zhou, Tianhua;Guo, Tao;Wang, Chenglong
    • Steel and Composite Structures
    • /
    • 제32권2호
    • /
    • pp.265-279
    • /
    • 2019
  • The self-centering capacity and energy dissipation performance have been recognized critically for increasing the seismic performance of structures. This paper presents an innovative steel moment frame with self-centering steel reinforced concrete (SRC) wall panel incorporating replaceable energy dissipation devices (SF-SCWD). The self-centering mechanism and energy dissipation mechanism of the structure were validated by cyclic tests. The earthquake resilience of wall panel has the ability to limit structural damage and residual drift, while the energy dissipation devices located at wall toes are used to dissipate energy and reduce the seismic response. The oriented post-tensioned strands provide additional overturning force resistance and help to reduce residual drift. The main parameters were studied by numerical analysis to understand the complex structural behavior of this new system, such as initial stress of post-tensioning strands, yield strength of damper plates and height-width ratio of the wall panel. The static push-over analysis was conducted to investigate the failure process of the SF-SCWD. Moreover, nonlinear time history analysis of the 6-story frame was carried out, which confirmed the availability of the proposed structures in permanent drift mitigation.

Comparison of the centering ability of Wave.One and Reciproc nickel-titanium instruments in simulated curved canals

  • Lim, Young-Jun;Park, Su-Jung;Kim, Hyeon-Cheol;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • 제38권1호
    • /
    • pp.21-25
    • /
    • 2013
  • Objectives: The aim of this study was to evaluate the shaping ability of newly marketed single-file instruments, Wave One (Dentsply-Maillefer) and Reciproc (VDW GmbH), in terms of maintaining the original root canal configuration and curvature, with or without a glide-path. Materials and Methods: According to the instruments used, the blocks were divided into 4 groups (n = 10): Group 1, no glide-path / Wave One; Group 2, no glide-path / Reciproc; Group 3, #15 K-file / Wave One; Group 4, #15 K-file / Reciproc. Pre- and post-instrumented images were scanned and the canal deviation was assessed. The cyclic fatigue stress was loaded to examine the cross-sectional shape of the fractured surface. The broken fragments were evaluated under the scanning electron microscope (SEM) for topographic features of the cross-section. Statistically analysis of the data was performed using one-way analysis of variance followed by Tukey's test (${\alpha}$ = 0.05). Results: The ability of instruments to remain centered in prepared canals at 1 and 2 mm levels was significantly lower in Group 1 (p < 0.05). The centering ratio at 3, 5, and 7 mm level were not significantly different. Conclusions: The Wave One file should be used following establishment of a glide-path larger than #15.

엔진구동형 NiTi 파일의 근관성형효과 비교 (A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS)

  • 김보혜;최경규;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.88-95
    • /
    • 2010
  • 이 연구의 목적은 4가지 엔진구동형 NiTi 기구의 근관성형력을 비교하는 것이다. 32개의 투명레진모형을 사용하여 파일의 단면도가 S자 형태이고 "single length"방법으로 근관성형을 시행하는 Mtwo와 crown-down 방법으로 근관성형을 하는 Profile, ProTaper Universal 및 K3로 근관성형을 하였다 (n = 8). 모든 근관은 한사람의 술자가 근단공 크기가 #30이 될 때까지 성형하였다. 기구 사용 전과 후 근관 모양을 디지털 영상을 기록하였고, 컴퓨터 영상 분석 프로그램(Expression Scanner와 Adobe Photoshop CS)으로 평가하였다. 다음과 같은 결론을 얻었다. 근첨으로부터 1, 2, 3, 4, 5, 6, 7 mm 떨어진 부위의 내측과 외측으로 삭제된 레진 양을 측정하였고, 자료는 SPSS법으로 비교 분석하였다. 1. 근관형성 시간은 Mtwo가 84.50초로 가장 짧았으며, 총 작업시간은 K3가 269.37초로 가장 길었다(p < 0.05). 2. 기구의 변형과 파절은 모든 구동형 NiTi 파일에서 발생하지 않았다. 3. 근관 내측 폭경의 변화는 Profile이 1, 2 mm 부위를 제외한 다른 부위에서 가장 적었으며, ProTaper Universal은 모든 부위에서 가장 많았다(p < 0.05). 4. 근관 외측 폭경의 변화는 Mtwo이 1 mm 부위를 제외한 모든 부위에서 가장 적었으며, Profile은 3, 4 mm 부위에서 가장 많았다(p < 0.05). ProTaper Universal와 K3는 1, 2, 6, 7 mm 부위에서 가장 많았다(p < 0.05). 5. 근관중심변위율(centering ratio)은 Profile이 1, 4, 5, 6 mm 부위에서 가장 적었다(p < 0.05). 이상의 결과, 구동성 NiTi 파일을 이용한 만곡 근관의 근관형성은 치경부는 ProTaper와 같은 삭제력이 높은 파일을 사용하는 것이 근관 입구를 효과적으로 넓히고 더 나은 taper를 형성하며, 근단부는 Profile과 같은 근관 중심 변위가 적은 파일을 사용하는 것이 근관형성 시간을 단축하고 근단부의 근관 변형(transportation)을 줄일 수 있다고 판단된다.

만곡된 레진 모형 근관에서 4종의 엔진 구동형 니켈-티타늄 기구의 근관 중심율 유지 능력 (The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals)

  • 구재훈;장훈상;장석우;조환희;배지명;민경산
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.113-118
    • /
    • 2006
  • 본 연구의 목적은 새로 시판된 NRT 기구의 근관 형태 유지 능력을 기존의 3종의 기구와 비교하는 것이다. 만곡된 레진 모형 근관을 ProFile, K3, ProTaper, NRT 기구를 이용하여 형성하였고 형성 전, 후의 상을 스캔한 후 중첩시켜 이미지 분석 프로그램을 이용하여 근관 만곡도의 변화와 근관 중심축에 대한 근관의 변이 정도를 근관 중심율의 변화로 계산하여 분석하였다. 근관 변이의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며 각 기구간의 유의성 검정은 Duncan's test로 사후 분석하였다. 근첨에서 1, 2 mm 상방 위치에서의 근관 중심율은 ProFile 군이 다른 군에 비해 우수한 것으로 나타났다. (p < 0.05). NRT기구의 근관 중심율 변화를 측정한 결과 근첨으로부터 5 mm 상방에서는 Profile에 비해서만 큰 것으로 나타났고 6, 7 mm 상방에서는 다른 모든 군들에 비해 큰 것으로 나타났다 (p < 0.05). 비록 NRT기구가 근첨 부위에서는 ProFile을 제외한 다른 기구에 비해 유의차 없는 중심률 유지 능력을 보였으나 근관 입구 및 중간부위의 형성에 사용되는 스테인레스-스틸 파일로 인해 coronal flaring시 다른 기구들에 비해 더 많은 중심률의 변화를 보이는 것으로 사료된다.

학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교 (COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES)

  • 강문성;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 연구의 목적은 학생들이 사용한 세 가지 Ni-Ti파일의 성형효율을 비교하고, 각 파일의 사용 경험 유무에 따른 차이를 비교하여 치과대학생을 위한 교육에 적합한 종류를 선택하는데 도움을 얻고자하는 것이다. Ni-Ti파일 사용 경험이 없는 학생 50명과 Ni-Ti파일을 사용한 근관치료 경력이 2년 이상인 경험자 10명이 세 종류의 Ni-Ti file - $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$ -을 사용하여 180개의 근관 모형을 성형하였다. 근관성형 시간 및 기구 변형, 근관 이형성을 조사하고 성형 전후 상을 중첩하여 근관 삭제폭, 근관변위량과 중심변위율을 1, 3. 5 mm에서 분석하였다. 1. 근관 성형시간은 HS군이 가장 빨랐으며, 총 삭제 량은 모든 지점에서 K3군이 다른 군보다 컸다 (P<0.05) . 2. 세 군 모두 1, 3 mm에서 외측 변이를 보였고, 1 mm지점에서 PF군이 가장 안정적이었다 (P<0.05). 3. 중심변위율은 1, 3 mm에서 HS, PF군이 K3군보다 작았다. 5 mm지점에서는 PF군이 가장 작았고, PF군 3 mm에서 학생은 경험자보다 유의하게 작았다 (P<0.05).

치과용 단층촬영을 이용한 Stainless-Steel File과 MFile-System® 전동식 기구의 근관 성형 능력에 대한 비교 연구 (A Comparison of Stainless-Steel File and MFile-System® Ni-Ti Rotary Instrument in Canal Preparation using Dental Computed Tomography)

  • 서동진;윤미란;이린;유미경
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.173-180
    • /
    • 2006
  • Objectives The aim of this study is to compare the quality of root canal preparation completed using MFile-$System^{(R)}$ instrument ( Komet, Gebr.Brsaseler, Germany) and conventional stainless steel file in the canals of Maxillary molar teeth that had a canal curvature between $25^{\circ}$ or more Materials & Methods Buccal canals of 24 first and second maxillary molar teeth, extracted for periodontal and prosthetic reasons were used. Tissue fragments and calcified debris were removed from teeth by scaling and the teeth were stored in 10% formalin solution for 24 hour. Then, teeth were stored in saline until used. To be included the roots had to have completed formed apices and angle of curvature ranging between $25^{\circ}$ or more according to the criteria described by Schneider(1971). Palatal and Second mesiobuccal canals were not included. Teeth were embedded into transparent acrylic. The teeth were randomly divided into two experimental groups. All teeth were scanned by Dental CT (PSR9000N, Asahi, Japan) to determine the root canal shape before instrumentation. Image slices were prepared from the apical end point to the pulp chamber. The first two sections were 2 mm from the apical end of root and 2 mm below the orifice. Further section was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. 12 teeth were instrumented using stainless steel fileand another 12 teeth were instrumented using MFile-$System^{(R)}$. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross sectional images taken prior to canal preparation. Amount of transportation and centering ability was assessed. Student's t-test was used for statistical analysis. Result Less transportation occurred with MFile-$System^{(R)}$ rotary instrumentation than stainless steel instrument. MFile-$System^{(R)}$ had better centering ability than stainless steel instrument. Conclusion MFile-$System^{(R)}$ rotary instrumentation transported canals less and had good centering ability.

엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향 (THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS)

  • 노형미;허복;김현철;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.486-492
    • /
    • 2005
  • 이 연구의 목적은 니켈-니타늄 파일의 삭제 성향과 엔진의 토크 조절 능력이 근관 성형에 미치는 영향을 평가하는 것이다 레진 모형 40개를 사용하였으며, Hero Shaper(R)와 Endo-Mate2을 이용한 HE군, Hero Shaper(R)와 Tecnika(R)를 이용한 HT군, Profile(R)과 Endo-Mate2(R)를 이용한 PE군, Profile(R)과 Tecnika(R)를 이용한 PT군으로 구분하여 근관성형 하였다. 각 군별 근관 성형 시간을 기록하였다. 근단공으로부터의 수직 이동 거리 1, 3 그리고 5mm 위치에서의 근관 삭제량, 중심이 동률을 산출하여 다음의 결론을 얻었다. 1. 근관 성형 시간은 HT군이 가장 빨랐다 (p<0.05). 2. 삭제량은 1mm지점에서 HE군이 PT군보다 컸고 (p<0.05), 3mm지점에서는 PT군이 다른 군들보다 작았다 (p<0.05). 5mm에서는 PE군이 PT군보다 컸다 (p<0.05). 3. 중심 이동률은 1mm 지점에서 HE군이 다른 군들보다 컸으며 (p<0.05), 5mm에서는 HT군이 PE군과 PT군보다 컸다 (p<0.05). 따라서 토크 조절이 되는 엔진을 사용하는 것이 근관의 변위를 적게 유발하고 과도한 삭제 량을 예방 할 수 있으며 근관 성형시간도 단축 할 수 있는 것으로 보이며 따라서 양호한 근관 성형 결과에 영향을 준다고 볼 수 있다.