• Title/Summary/Keyword: Center-of-mass

Search Result 4,964, Processing Time 0.04 seconds

Natural frequencies and response amplitude operators of scale model of spar-type floating offshore wind turbine

  • Hong, Sin-Pyo;Cho, Jin-Rae
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.785-794
    • /
    • 2017
  • This paper is concerned with the comparative numerical and experimental study on the natural behavior and the motion responses of a 1/75 moored scale model of a 2.5 MW spar-type floating offshore wind turbine subject to 1-D regular wave. Heave, pitch and surge motions and the mooring tensions are investigated and compared by numerical and experimental methods. The upper part of wind turbine which is composed of three rotor blades, hub and nacelle is modeled as a lumped mass and three mooring lines are pre-tensioned by means of linear springs. The numerical simulations are carried out by a coupled FEM-cable dynamics code, while the experiments are performed in a wave tank equipped with the specially-designed vision and data acquisition system. Using the both methods, the natural behavior and the motion responses in RAOs are compared and parametrically investigated to the fairlead position, the spring constant and the location of mass center of platform. It is confirmed, from the comparison, that both methods show a good agreement for all the test cases. And, it is observed that the mooring tension is influenced by all three parameters but the platform motion is dominated by the location of mass center. In addition, from the sensitivity analysis of RAOs, the coupling characteristic of platform motions and the sensitivities to the mooring parameters are investigated.

On Estimation of Indication, Property and Processing of Rhus Verniciflua Stokes (옻의 주치(主治).효능(效能).수치법(修治法)에 관(關) 소고(小考);11종 한약서를 중심으로)

  • Eom, Seok-Ki;Kim, Kyung-Suk
    • Journal of Korean Medical classics
    • /
    • v.21 no.2
    • /
    • pp.29-37
    • /
    • 2008
  • Based on 11 Classics of Materia Medica designated by Ministry of health and welfare bulletin 1995-15 as legal basis in scope and preparation of herbal prescription, we reviewed indication, property and processing of Rhus Verniciflua Stokes which appear extensively in literature since earlier Joseon Dynasty. Following is the conclusion of this review after comparing with 'Korean Pharmacopoeia: commentary on herbal product standard'. 1. The properties of Rhus Verniciflua Stokes in 'Korean Pharmacopoeia :commentary on herbal product standard' should be changed as 'Tonifying the middle, restoring the muscle, fulfilling marrow, breaking old static blood, tonifying and activating after removing mass, unblocking the meridian, killing worms' and indication should be changed as 'Old static blood, deep rooted mass, wind-cold-dampness arthralgia, cough, 9 types of chest pain, abdominal or flank accumulation of stagnated qi[氣], amenorrhea, hernia mass, small bowel or bladder colic pain, abdominal pain due to worm accumulation'. 2. The processing of Rhus Verniciflua Stokes in 'Korean Pharmacopoeia: commentary on herbal product standard' should include 'natural drying or steaming drying followed by grinding and stir-baking until ripened or smoking appears'.

  • PDF

Identification of IY81149 and Its Metabolites in the Rat Plasma Using the On-Line HPLC/ESI Mass Spectrometry

  • Myung, Seung-Woon;Min, Hye-Ki;Jin, Chang-Bae;Kim, Myung-Soo;Lee, Seung-Mok;Chung, Gi-Ju;Park, Seong-Jun;Kim, Dong-Yeon;Cho, Hyun-Woo
    • Archives of Pharmacal Research
    • /
    • v.22 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Reversed-phase high-performance liquid chromatography/mass spectrometry (HPLC/MS) with an eletcrospray ionization (ESI) interface was applied to the identification of metabolites of IY81149 in the rat plasma. Fragments obtained using collision-induced dissociation (CID) in both positive and negative modes were utilized to elucidate the structure of metabolites. The eluent from the conventional HPLC column was split and directly introduced into an ESI-mass spectrometer for the identification of the structures. the CID technique allowed the sensitive identification of sulfonyl-IY81149 and hydroxy-IY81149 from the rat plasma.

  • PDF

Currarino Triad

  • Lee, Ho-Jin;Kong, Min-Ho;Kim, Dong-Seok;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.1
    • /
    • pp.63-66
    • /
    • 2005
  • The authors report a case of Currarino triad which had a congenital anorectal stenosis associated with a sacral defect and a presacral mass. A 1-year-old female presented with constipation since birth. Neurological deficits were not found on admission. She had had a diverting colostomy due to anorectal stenosis at another hospital before admission. Lumbar X-ray films showed bony defect caudal to the third sacral vertebra. Magnetic resonance image demonstrated a round cystic pelvic mass which was connected with a dural sac via anterior sacral defect. Posterior approach with Intradural removal of the presacral cystic mass was performed and followed by anoplasty by a pediatric surgeon. The cystic mass was verified histologically as mature teratoma with cystic change. Postoperatively, the urinary function and bowel movement remained intact. Currarino triad should be suspected and evaluated physically and radiographically in a case of congenital anorectal stenosis. Prompt recognition and close cooperation between pediatric surgeons and neurosurgeons is advisable to ensure adequate surgical treatment.

Recent Progress on Microfluidic Electrophoresis Device Application in Mass Spectrometry

  • Roy, Swapan Kumar;Kim, Seongnyeon;Yoon, Jung H.;Yoon, Yong-Kyu;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2018
  • Microfluidic technologies hold high promise and emerge as a potential molecular tool to facilitate the progress of fundamental and applied biomedical researches by enabling miniaturization and upgrading current biological research tools. In this review, we summarize the state of the art of existing microfluidic technologies and its' application for characterizing biophysical properties of individual cells. Microfluidic devices offer significant advantages and ability to handle in integrating sample processes, minimizing sample and reagent volumes, and increased analysis speed. Therefore, we first present the basic concepts and summarize several achievements in new coupling between microfluidic devices and mass spectrometers. Secondly, we discuss the recent applications of microfluidic chips in various biological research field including cellular and molecular level. Finally, we present the current challenge of microfluidic technologies and future perspective in this study field.

A primo vessel-like structure in a dog with inflammatory pseudotumor

  • Cho, Sung-Jin;Hong, Sun-Hwa;Han, Sang-Jun;Kim, Ok-Jin
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.1
    • /
    • pp.77-82
    • /
    • 2012
  • Inflammatory pseudotumor (IPT) is a term defining a mass characterized microscopically by a proliferation of bland mesenchymal spindle cells infiltrated by diffuse mixed inflammatory cells with a predominance of plasma cells and lymphocytes. Here, we show the primo vessel-like structure of the primo-vascular system (PVS) in a dog with IPT. A 6-years old male Mongrel dog was diagnosed with an abnormal mass (diameter 5.5 cm, weight 22 g) near left preputial area. The dog was submitted to the surgical detectomy of the mass. During the surgical operation, we observed primo vessel-like material. After fixations, the masses appeared macroscopically as lipoid-like, firm, white to grey masses, measuring $5{\times}8cm$. Histologically, cellular infiltration into the muscular layers was frequently seen. The mesenchymal proliferation remained the main component of the mass and was composed of myofibroblastic-like spindle cells characterized by globular, irregular nuclei containing open chromatin and a prominent nucleolus. On the basis of the histopathologic lesions, the subcutaneous mass was diagnosed as IPT. Also, we detected a primo vessel-like structures in some areas of the IPT tissues. These were observed as novel thread-like structures and bundle of tubular structures. To our knowledge, this report is the first case of primo vessel-like structure in a dog with IPT.

Real-Time CoM/ZMP Trajectory Transformation Method for Humanoid Robots Considering Structure Characteristics (구조 특성을 반영한 인간형 로봇을 위한 실시간 CoM/ZMP 궤적 변환 방법)

  • Hong, Seok-Min
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.132-137
    • /
    • 2017
  • This paper proposes a transformation method of the zero moment point (ZMP) and the center of mass (CoM) from one walking pattern to other patterns by considering the structure of a robot or walking situations in real time. In general, a humanoid robot has own structure characteristics like height and mass. The structure characteristics make the given CoM/ZMP walking pattern of one human or one humanoid robot to be difficult to apply to other robot directly. For this purpose, we analyze the characteristics of walking patterns according to the step length, duration of walking support phase and the CoM height by using the cart-table model as the simple humanoid robot model. A transformation equation is derived from the analyzation and it is verified with simulation.

A Case of Primary Large B-cell Lymphoma of Larynx Presenting as Supraglottic Mass (성문상부 종물 양상의 일차성 후두 Large B세포 림프종 1예)

  • Choi, Jeon Ha;Kim, Choon Dong;Kim, Yoon Jung;Kim, Seung Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.31-33
    • /
    • 2015
  • The extranodal non-Hodgkin lymphoma is uncommonly occurred in larynx, accounting for less than 1% of all laryngeal neoplasm. In general, the laryngeal lymphoma is appeared as submucosal mass without mucosal ulceration and is most commonly found in supraglottis. The primary laryngeal lymphoma constitute a diagnostic challenge because they are characterized by absence of clinical and gross differential criteria, compared with squamous cell carcinoma (SCC). We encountered a 74-year-old man with hoarseness and lump sensation in the throat. On direct laryngoscope, multiple ulcerative and exudative mass in glottis and supraglottic areas were observed. The patient was finally diagnosed as large B-cell lymphoma through the laryngeal microsurgery. He received radiation therapy and there is no evidence of recurrence. Although the laryngeal mass has superficial mucosal change, primary laryngeal lymphoma must be included in the differential diagnosis.

  • PDF

Sll0396 regulates transcription of the phycocyanin genes in Synechocystis sp. PCC 6803

  • Oh, In-Hye;Kim, Ho-San;Chung, Young-Ho;Kim, Young-Hye;Park, Young-Mok
    • Plant Biotechnology Reports
    • /
    • v.4 no.3
    • /
    • pp.193-199
    • /
    • 2010
  • An olive-green mutant was generated in Synechocystis sp. strain PCC 6803 by inactivation of the sll0396 gene. Whole-cell absorption spectra of the mutant revealed the missing of phycocyanin peak. An investigation of the low-temperature fluorescence emission spectra revealed that the $sll0396{\Omega}$ mutant has a reduced amount of phycocyanin. Western blot analysis showed that the mutant contained less phycocyanin ${\beta}$- and ${\alpha}$-subunits and lacked the 30- and 32-kDa linker polypeptides, and northern blot analysis revealed that the transcription of the 1.4-kb cpcBA gene encoding the phycocyanin ${\beta}$- and ${\alpha}$-subunits was lower in the mutant. The Sll0396 protein has a DNA-binding motif and shares homology with known response regulators. Our results indicate that Sll0396 plays a regulatory role in the transcription of the phycocyanin genes during phycobilisome synthesis.

A High-Lateral Resolution MALDI Microprobe Imaging Mass Spectrometer Utilizing an Aspherical Singlet Lens

  • Han, Sang Yun;Kim, Hwan Jin;Ha, Tae Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.207-210
    • /
    • 2013
  • We report the construction of a MALDI imaging mass spectrometer equipped with a specially designed laser focusing lens, a compact aspherical singlet lens, that obtains a high-lateral imaging resolution in the microprobe mode. The lens is specially designed to focus the ionization laser (${\lambda}$ = 355 nm) down to a $1{\mu}m$ diameter with a long working distance of 34.5 mm. With the lens being perpendicular to the sample surface and sharing the optical axis with the ion path, the imaging mass spectrometer achieved an imaging resolution of as good as $5{\mu}m$ along with a high detection sensitivity of 100 fmol for peptides. The mass resolution was about 900 (m/${\Delta}m$) in the linear TOF mode. The high-resolution capability of this instrument will provide a new research opportunity for label-free imaging studies of various samples including tissues and biochips, even for the study at a single cell level in the future.