• 제목/요약/키워드: Center of Pressure (CoP)

검색결과 133건 처리시간 0.029초

Transient effects of jumping lunge on sand on balance ability in healthy adults: a preliminary study

  • Choi, Min-hyeok;Shin, Ho-jin;Hahm, Suk-Chan;Lee, Min-Goo;Cho, Hwi-young
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.172-178
    • /
    • 2018
  • Objective: The purpose of this study was to show the temporary effects of performing jumping lunges on a sand surface on static balance and dynamic balance. Design: Randomized controlled trial. Methods: Twenty healthy subjects volunteered in the study and was randomly assigned into either the sand group (n=10) or the control group (n=10). The subjects in the sand group performed jumping lunges on a sand surface and the subjects in the control group performed jumping lunges on a firm surface. The intervention was performed for 3 sets of 8 repetitions by both groups. To measure static balance, the force plate was employed to measure the center of pressure (CoP) area, and the CoP velocity during one-legged standing. Anterior, postero-medial, postero-lateral movements was assessed using the Star Excursion Balance Test (SEBT) to measure dynamic balance. Results: After the intervention, the sand group showed statistically significant improvements on all variables (CoP area, CoP velocity) in static balance (p<0.05). There were statistically significant changes in CoP area and CoP velocities between the two groups (p<0.05). In the sand group, there were significant improvements in the postero-medial and postero-lateral directions (p<0.05) except for anterior direction on dynamic balance. In the control group, there was a significant improvement in the postero-lateral and anterior directions (p<0.05). In comparison of the two groups, there was no statistically significant improvement in all variables. Conclusions: This study demonstrated that performing jumping lunges on a sand surface was effective in improving static and dynamic balance temporarily.

토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구 (Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung)

  • 안창혁;고영민;박정웅;서지영;고원중;임성용;김철홍;안영미;정만표;김호중;권오정
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권1호
    • /
    • pp.14-23
    • /
    • 2002
  • 배 경 : 부분액체환기 (partial liquid ventilation; PLV) 시 최적의 기계환기의 설정에 대해서는 아직 논란이 많은 상태이다. 이에 정상 폐의 PLV 시 가스교환에 영향을 주는 인자들을 관찰함으로써, PLV 시 최적의 기계환기 설정을 확립하는 데에 이용하고자 본 연구를 시행하였다. 방 법 : New Zealand 산 백색 토끼 7 마리를 기계환기를 시행하였다. 기계환기는 압력 조절 양식으로 일회호흡량 ($V_T$) 8 mL/kg, PEEP 4 $cmH_2O$, 흡기대호기비 (I: E ratio) 1:2, 흡입산소분율 ($F_IO_2$) 0.75로 설정하였고, 호흡수(RR)는 $PaCO_2$가 35~45 mmHg 사이에 유지되도록 조절하였다. 이후 30분마다 기계환기기의 설정을 protocol에 따라 변화시키면서 가스환기(gas ventilation; GV)를 시행하였는데 ; (1) 기저 설정 단계, (2) 역비환기 (inverse I: E ratio) 단계로 I:E ratio 2:1, (3) 고 PEEP 단계로 2단계와 같은 평균흡기압 (MIP)을 유지하는 정도의 PEEP 증가, (4) 고 $V_T$ 단계로 $V_T$ 15 mL/kg, (5) 고RR 단계로 4단계와 같은 분당환기량 (MV)을 유지하는 정도로 RR을 증가시켰다. 그 후 perfluorodecalin 18 mL/kg 주입 후 상기 protocol과 동일하게 PLV를 하였다. 각각에서 동맥혈가스검사와 폐역학 및 혈역학적 지표를 측정하였다. 결 과 : (1) GV 시 $PaO_2$는 다섯 단계를 거치는 동안 의미 있는 변화를 보이지 않았다. $PaCO_2$는 고 $V_T$단계와 고 RR 단계에서 의미 있게 감소하였다(p<0.05). GV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다. (2) PLV 군의 기저 $PaO_2$$312{\pm}113$ mmHg로 GV군의 $504{\pm}81$ mmHg 에 비해 의미 있게 낮았다(p=0.001). PLV 시 역비환기 단계나 고 RR 단계에서는 기저설정 단계와 비교하여 $PaO_2$의 의미 있는 차이가 관찰되지 않았으나, 고 PEEP 단계 ($452{\pm}38$ mmHg)와 고 $V_T$($461{\pm}53$ mmHg) 단계에서는 기저설정 단계보다 유의한 상승이 관찰되었다. (3) $PaCO_2$는 GV군과 PLV군 모두에서 고 $V_T$ 단계와 고 RR 단계에서 기저설정 단계보다 의미 있게 낮았다. PLV군의 기저설정 단계와 고 RR 단계의 $PaCO_2$는 GV 군보다 의미 있게 증가하였다(p<0.05). (4) PLV 시 폐역학 및 혈역학적 지표의 의미 있는 변화는 보이지 않았다 결 론 : 정상 폐에서 PLV 시 최적의 가스교환을 위해서는 적절한 PEEP과 $V_T$이 중용할 것으로 사료된다.

An Analytical Study on the Performance Analysis of a Unit-In-jector System of a Diesel Engine

  • Kim, Chul-Ho;Lee, Jong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.146-156
    • /
    • 2003
  • A numerical algorithm is developed to analyze the performance of a Unit-injector (UI) System for a diesel engine. The fundamental theory of the algorithm is based on the continuity equation of fluid dynamics. The loss factors that should be seriously regarded on the continuity equation are the compressibility effect of liquid fuel, the wall friction loss in high-pressure fuel lines of the system, the kinetic energy loss of fuel in the system, and the leakage of fuel out of the control volume. For an evaluation of the developed simulation algorithm, the calculation results are compared with the experimental outputs provided by the Technical Research Center of Doowon Precision Industry Co. (DPICO) ; the maximum pressure in the plunger chamber (P$\_$p/) and total amount of fuel injected into a cylinder per cycle (Q$\_$f/) at each operational condition. The result shows that the average error rate (%) of P$\_$p/ and Q$\_$f/ are 2.90% and 4.87%, respectively, in the specified operational conditions. Hence, it can be concluded that the analytical simulation algorithm developed in this study can be reasonably applied to the performance prediction of newly designed UI system.

THE MAGNETIC PROPERTIES OF Co-Ni-Fe-N SOFT MAGNETIC THIN FILMS

  • Kim, Y. M.;Park, D.;Kim, K. H.;Kim, J.;S. H. Han;Kim, H. J.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.492-499
    • /
    • 2000
  • Co-Ni-Fe-N thin films were fabricated by a N$\sub$2/ reactive rf magnetron sputtering method. The nitrogen partial pressure (P$\sub$N2/) was varied in the range of 0∼10%. As P$\sub$N2/ increases in this range, the saturation magnetization (B$\sub$s/) linearly decreases from 19.8 kG to 14 kG and the electrical resistivity ($\rho$) increased from 27 to 155 ${\mu}$$\Omega$cm. The coercivity (H$\sub$c/) exhibits the minimum value at 4% of P$\sub$N2/. The magnetic anisotropy (H$\sub$k/) are in the range of 20∼50 Oe. High frequency characteristics of (Co$\sub$22.2/Ni$\sub$27.6/Fe$\sub$50.2/)$\sub$100-x/N$\sub$x/ films are excellent in the range of 3∼5% of P$\sub$N2/. Especially the effective permeability of the film fabricated at 4% of P$\sub$N2/ is 800, which is maintained up to 600 MHz. This film also shows Bs of 17.5 kG, H$\sub$c/ of 1.4 Oe, resistivity of 98 $\Omega$cm and H$\sub$k/ of about 25 Oe. Also, the corrosion resistance of (Co$\sub$22.2/Ni$\sub$27.6/Fe$\sub$50.2/)$\sub$100-x/N$\sub$x/ were improved with the increase in N concentration.

  • PDF

The Magnetic Properties of Co-Ni-Fe-N Soft Magnetic Thin Films

  • Kim, Y. M.;Park, D.;Kim, K. H.;Kim, J.;S. H. Han;Kim, H. J.
    • Journal of Magnetics
    • /
    • 제5권4호
    • /
    • pp.120-123
    • /
    • 2000
  • Co-Ni-Fe-N thin films were fabricated by a $N_2$ reactive rf magnetron sputtering method. The nitrogen partial pressure ($P_{N2}$) was varied in the range 0~10% . As$P_{N2}$ increases in this range, the saturation magnetization $B_s$ linearly decreases from 19.8 kG to 14 kG and the electrical resistivity ($\rho$) increases from 27 to 155 $\mu\Omegacm$. The coercivity $H_c$ exhibits the minimum value at 4% $P_{N2}$. The magnetic anisotropy fields ($H_k$) are in the range of 20$\sim$50 Oe. High frequency characteristics of $(Co_{22.2}Ni_{27.6}Fe_{50.2})_{100-x}N_x$ films are excellent in the range of 3$\sim$5% of $P_{N2}$. In particular, the effective permeability of the film fabricated at 4% $P_{N2}$ is 800, which is maintained up to 600 MHz. This film also shows Bs of 17.5 kG, $H_c$/ of 1.4 Oe, resistivity of 98$\mu\Omegacm$ and $H_k$ of about 25 Oe. Also, the corrosion resistance of $(Co_{22.2}Ni_{27.6}Fe_{50.2})_{100-x}N_x$ films was imp roved with increasing N concentration.

  • PDF

PF 열교환기가 적용된 슬림형 중계기 냉각기 (Slim Electronic Panel Cooler with Parallel Flow Condenser)

  • 조진표;김내현;이재훈;이진용;목인균;임원경;임석선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.483-488
    • /
    • 2006
  • In this study, newly-developed slim electronic panel cooler with aluminum PF condenser and evaporator was tested and the results are compared with imported panel cooler with fin-tube heat exchangers. The PF heat exchangers significantly (approximately 45%) reduced the refrigerant charge. The air-side pressure drop was also reduced, which resulted in the reduction of the sound level of the panel cooler. The effect of the condenser size was also investigated.

  • PDF

중증 뇌손상 환자에서 고농도 산소치료법 (The High Concentration Oxygen Therapy in Severe Head Injury Patients)

  • 박성호;박한준;윤승환;조준;문창택;장상근
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup1호
    • /
    • pp.37-43
    • /
    • 2001
  • Object : The rapid and early oxygen delivery to brain tissue was a common therapeutic method in the treatment of severe head injury patients. The purpose of this study was to investigate the effect of increased fraction of inspired oxygen in early stage of severe head injury. Methods : The parameters of research were CSF(cerebral spinal fluid) oxygen pressure($PcsfO_2$), lactate, pH, temperature, and CSF carbon dioxide pressure($PcsfCO_2$). We selected 28 patients with head trauma whose the Glasgow Coma Scale(GCS) score was less than 8 point at admission. All patients were mechanically ventilated and monitored with the commercial ICP monitoring device. Each of parameters was compared as increased fraction of inspired oxygen. In experimental cohort of 14 patients, the mean $PcsfO_2$ level was increased to $314.93{\pm}259.15mmHg$ by raising the $FiO_2$ from 40% to 100% for nine hours(p<0.05). And the mean CSF lactate level was decreased to $2.96{\pm}1.98mmol/L$ on 100% $FiO_2$ as compared with $5.98{\pm}3.25mmol/L$ on 40% $FiO_2$ in control group(p<0.05). The only above two parameters were showed statistically meaningful outcome. Conclusions : Although this study was performed in small cohort and short period, these results supports that increased inspired oxygen therapy in severe head injuried patients was recommended as a modality of treatment in future through the continuous survey.

  • PDF

합성 고분자물질 A611P를 첨가한 기액 2상 수직상향의 유동특성에 관한 실험적 연구 (Experimental study on the flow characteristic by the co-polymer A6l1P additive in gas-liquid two-phase vertical up flow)

  • 차경옥;김재근;양회준
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.398-410
    • /
    • 1998
  • Two-phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and the liquid transportation system. The particular flow pattern depends on the conditions of pressure, flow velocity, and channel geometry. However, the research on drag reduction in two-phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction and void fraction by polymer addition in the two-phase flow system. We find that the polymer solution changes the characteristic of two-phase flow. The peak position of local void friction moves from tile wall of the pipe to the center of the pipe when polymer concentration increase. And then we predict that it is closely related with the frau reduction.

  • PDF

pH가 낮은 탄산수의 CO2 탈기에 따른 용존탄소동위원소 변화 (Changes of carbon-13 Isotope of Dissolved Inorganic Carbon Within Low-pH CO2-rich Water during CO2 Degassing)

  • 채기탁;유순영;김찬영;박진영;방하은;이인혜;고동찬;신영재;오진만
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제24권3호
    • /
    • pp.24-35
    • /
    • 2019
  • It is known that ${\delta}^{13}C_{DIC}$ (carbon-13 isotope of dissolved inorganic carbonate (DIC) ions) of water increases when dissolved $CO_2$ degases. However, ${\delta}^{13}C_{DIC}$ could decrease when the pH of water is lower than 5.5 at the early stage of degassing. Laboratory experiments were performed to observe the changes of ${\delta}^{13}C_{DIC}$ as $CO_2$ degassed from three different artificial $CO_2$-rich waters (ACWs) in which the initial pH was 4.9, 5.4, and 6.4, respectively. The pH, alkalinity and ${\delta}^{13}C_{DIC}$ were measured until 240 hours after degassing began and those data were compared with kinetic isotope fractionation calculations. Furthermore, same experiment was conducted with the natural $CO_2$-rich water (pH 4.9) from Daepyeong, Sejong City. As a result of experiments, we could observe the decrease of DIC and increase of pH as the degassing progressed. ACW with an initial pH of 6.4, ${\delta}^{13}C_{DIC}$ kept increasing but, in cases where the initial pH was lower than 5.5, ${\delta}^{13}C_{DIC}$ decreased until 6 hours. After 6 hours ${\delta}^{13}C_{DIC}$ increased within all cases because the $CO_2$ degassing caused pH increase and subsequently the ratio of $HCO_3{^-}$ in solution. In the early stage of $CO_2$ degassing, the laboratory measurements were well matched with the calculations, but after about 48 hours, the experiment results were deviated from the calculations, probably due to the equilibrium interaction with the atmosphere and precipitation of carbonates. The result of this study may be not applicable to all natural environments because the pressure and $CO_2$ concentration in headspace of reaction vessels was not maintained constant as well as the temperature. Nevertheless, this study provides fundamental knowledge on the ${\delta}^{13}C_{DIC}$ evolution during $CO_2$ degassing, and therefore it can be utilized in the studies about carbonated water with low pH and the monitoring of geologic carbon sequestration.

고혈압 전단계 및 고혈압 환자에서 의학영양치료와 병행한 생리활성 펩티드 함유 유산균 발효유 섭취가 혈압에 미치는 영향 (Effect of Supplementation of Fermented Milk Containing Active Peptides(IPP, VPP) in Accordance with Medical Nutrition Therapy in Pre- and Hypertension Subjects)

  • 김지영;김윤영;김혜랑;윤숭섭;김완식;예현수;정진영;이인회;조여원
    • 동아시아식생활학회지
    • /
    • 제18권6호
    • /
    • pp.918-926
    • /
    • 2008
  • 본 연구는 2006년 1월부터 2007년 5월까지 수축기/이완기 혈압이 120/80 mmHg이상인 고혈압 전단계 및 본태성 고혈압 환자 43명 (대조군 21명, 시험군 23명)을 대상으로 12주간의 의학 영양 치료와 병행하여 생리활성 펩타이드가 함유된 유산균 발효유 섭취가 혈압에 미치는 영향을 조사한 결과를 요약하면 다음과 같다. 1. 본 연구 대상자의 평균 연령은 대조군이 $47.8{\pm}12.9$세, 시험군은 $49.9{\pm}11.9$세였으며, 연구 시작 시 혈압은 각 군에서 수축기/이완기 혈압이 $135.4{\pm}8.8/85.0{\pm}6.9$, $135.7{\pm}7.4/88.0{\pm}5.5\;mmHg$로 군 간의 차이가 없었다. 2. 식이 섭취 조사 결과, 연구 12주 후 대조군, 시험군 모두 열량, 단백질, 지질, 콜레스테롤, 나트륨의 섭취가 유의적으로 감소하였다(p<0.05). 칼슘과 칼륨의 섭취는 시험군에서만 유의적으로 증가하였으며, 다른 영양소의 섭취는 군 간에는 유의적인 차이를 보이지 않았다. 3. 연구 기간 동안 수축기 혈압은 대조군과 시험군 모두 연구 4주 후부터 유의적인 감소를 보였으며, 연구 12주까지 두 군 모두에서 유의적으로 감소하였다(p<0.05). 이완기 혈압은 시험군에서만 연구 4주 후부터 유의적으로 감소하였다(p<0.05). 결론적으로, 고혈압 전단계 및 고혈압 환자에게 12주간의 의학 영양 치료와 함께 유산균 발효유의 섭취는 총열량, 지방, 콜레스테롤, 나트륨의 섭취를 감소시켰고 칼슘 및 칼륨의 섭취를 증가시켰으며 수축기와 이완기 혈압을 유의적으로 감소시켰다. 따라서 생리활성 펩타이드가 함유된 유산균 발효유를 의학영양치료와 병행하여 섭취할 경우, 수축기 혈압감소뿐만 아니라 이완기 혈압 감소 모두에 긍정적인 영향을 미칠 것으로 기대한다.

  • PDF