• Title/Summary/Keyword: Center of Mass

Search Result 4,838, Processing Time 0.036 seconds

An occurrence of mammary spindle cell carcinoma in a dog

  • Hong, Sunhwa;Lee, Hyun-A;Kim, Dong-Woo;Kim, Tae-Wan;Kim, Okjin
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.4
    • /
    • pp.313-317
    • /
    • 2014
  • A bitch was presented for investigation of the mass in left 5th mammary gland. The partial mastectomy was performed and submitted for the histopathological diagnosis. The mammary mass was firm and white colored. The cut surface was separated with several lobules and developed vessels. The central area of the mass formed the cavity filled with inflammatory exudates. The dominant component of the tumor was the bundles of spindle-shaped cells. Some tumor cells possessed atypical nuclei and were arranged in a solid nest. Cysts were microscopically composed of hemorrhage, necrosis, and exudates, partially surrounded by tumor cells and granulation tissues. Histopathologically, the mammary mass revealed spindle cell carcinoma. The bitch made a complete recovery following the mastectomy. This case was a rare mammary spindle cell carcinoma in a dog.

Estimation of Particle Mass Concentration from Lidar Measurement (라이다 관측자료를 이용한 미세먼지 농도 산정)

  • Kim, Man-Hae;Yeo, Huidong;Sugimoto, Nobuo;Lim, Han-Cheol;Lee, Chul-Kyu;Heo, Bok-Haeng;Yu, Yung-Suk;Sohn, Byung-Ju;Yoon, Soon-Chang;Kim, Sang-Woo
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.169-177
    • /
    • 2015
  • Vertical distribution of particle mass concentrations was estimated from 8-year elastic-backscatter lidar and sky radiometer data, and from ground-level PM10 concentrations measured in Seoul. Lidar ratio and mass extinction efficiency were determined from aerosol optical depth (AOD) and ground-level PM10 concentrations, which were used as constraints to estimate particle mass concentration. The mean lidar ratio (with standard deviation) and mass extinction efficiency for the entire 8-year study period were $60.44{\pm}23.17$ sr and $3.69{\pm}3.00m^2g^{-1}$, respectively. The lidar ratio did not vary significantly with the ${\AA}ngstr{\ddot{o}}m$ exponent (less than ${\pm}10%$); however, the mass extinction efficiency decreases to $1.82{\pm}1.67m^2g^{-1}$ (51% less than the mean value) when the ${\AA}ngstr{\ddot{o}}m$ exponent is less than 0.5. This result implies that the particle mass concentration from lidar measurements can be underestimated for dust events. Seasonal variation of the particle mass concentration estimated from lidar measurements for the boundary layer, was quite different from ground-level PM10 measurements. This can be attributable to an inhomogeneous vertical distribution of aerosol in the boundary layer.

Method for Screening and Confirming Meldonium in Human Urine by High-Resolution Mass Spectrometry and Identification of Endogenous Interferences for Anti-Doping Testing

  • Kim, Yongseok;Jeong, Dawon;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.39-43
    • /
    • 2017
  • Meldonium is a drug for treating ischemia by expanding the arteries but it can also enhance the performance of sports players. The World Anti-Doping Agency (WADA) has included it in the list of prohibited substances since 2016. Meldonium is one of the challenging substances for anti-doping testing because it is difficult to recover by general liquid-liquid or solid phase extraction due to its permanent charge and high polarity. Therefore, high-performance liquid chromatography (HPLC) is currently used by injecting a diluted urine sample (known as the "dilute-and-shoot" strategy). There is no loss of target compounds in the extraction/cleanup procedure but its high matrix effect could interfere in their separation or detection from the endogenous urinary compounds. We report a single method using high-resolution mass spectrometry that can be used for both screening and confirmation, which follows the "dilute-and-shoot" strategy. In this method, the endogenous compounds' interfering peaks in the mass spectrum are separated at a high resolution of FWHM 140,000, and the results are suitable for substance detection following the WADA guidelines. The interferences in the obtained mass spectrum of the urine matrix are identified as acetylcholine, lysine, and glutamine by further analysis and database searching. Validation of the method is performed in routine anti-doping testing, and the limit of detection is 50 ng/mL. This method uses simple sample preparation and a general reverse phase HPLC column, and it can be easily applied to other substances.

Characterization of Molecular Composition of Bacterial Melanin Isolated from Streptomyces glaucescens Using Ultra-High-Resolution FT-ICR Mass Spectrometry

  • Choi, Mira;Choi, A Young;Ahn, Soo-Yeon;Choi, Kwon-Young;Jang, Kyoung-Soon
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • In this study, the chemical composition of bacterial melanin isolated from the Streptomyces glaucescens strain was elucidated by ultra-high-resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. Ultra-high-resolution mass profiles of the microbial melanin product were acquired using a 15 Tesla FT-ICR mass spectrometer in positive and negative ion modes via electrospray ionization to obtain more complete descriptions of the molecular compositions of melanin-derived organic constituents. A mass resolving power of 500,000 (at m/z 400) was achieved for all spectra while collecting 400 scans per sample with a 4 M transient. The results of this analysis revealed that the melanin pigment isolated from S. glaucescens predominantly exhibits CHON and CHO species, which belong to the proteins class of compounds, with the mean C/O and C/N ratios of 4.3 and 13.1, thus suggesting that the melanin could be eumelanin. This analytical approach could be utilized to investigate the molecular compositions of a variety of natural or synthetic melanins. The compositional features of melanins are important for understanding their formation mechanisms and physico-chemical properties.

Comparison of Lipid Profiles in Head and Brain Samples of Drosophila Melanogaster Using Electrospray Ionization Mass Spectrometry (ESI-MS)

  • Jang, Hyun Jun;Park, Jeong Hyang;Lee, Ga Seul;Lee, Sung Bae;Moon, Jeong Hee;Choi, Joon Sig;Lee, Tae Geol;Yoon, Sohee
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.11-17
    • /
    • 2019
  • Drosophila melanogaster (fruits fly) is a representative model system widely used in biological studies because its brain function and basic cellular processes are similar to human beings. The whole head of the fly is often used to obtain the key function in brain-related diseases like degenerative brain diseases; however the biomolecular distribution of the head may be slightly different from that of a brain. Herein, lipid profiles of the head and dissected brain samples of Drosophila were studied using electrospray ionization-mass spectrometry (ESI-MS). According to the sample types, the detection of phospholipid ions was suppressed by triacylglycerol (TAG), or the specific phospholipid signals that are absent in the mass spectrum were measured. The lipid distribution was found to be different in the wild-type and the microRNA-14 deficiency model ($miR-14{\Delta}^1$) with abnormal lipid metabolism. A few phospholipids were also profiled by comparison of the head and the brain in two fly model systems. The mass spectra showed that the phospholipid distributions in the $miR-14{\Delta}^1$ model and the wild-type were different, and principal component analysis revealed a correlation between some phospholipids (phosphatidylethanolamine (PE), phosphatidylinositol (PI), and phosphatidylserine (PS)) in $miR-14{\Delta}^1$. The overall results suggested that brain-related lipids should be profiled using fly samples after dissection for more accurate analysis.

The Relative Incidence of Neoplastic Versus Non-neoplastic Mass in Major Salivary Gland Area Diagnosed by Surgery (주타액선부위에 발생한 종괴의 비교분석)

  • Oh Kyung-Kyoon;Chang Kyung-Man;Park Mi-Hyang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.10 no.2
    • /
    • pp.157-162
    • /
    • 1994
  • It is the purpose of this paper to determine the relative frequency of the neoplastic vs. non-neoplastic disease in a series of surgically removed parotid and submandibular masses. The study was conducted a retrospective review of 249 consecutive, operated patients' records seen over a 9-year period from 1985 through 1993 at Department of Otolaryngology-Head and Neck Surgery, Korea Cancer Center Hospital. One hundred and fifteen patients had parotid mass and 134 patients had submandibular mass. All the specimen surgically removed were studied histopathologically. The numbers and percentages of patients are reported along with a pathological classification of the lesions encountered: neoplastic(benign, malignant) and non-neoplastic (inflammatory, non-inflammatory). There were 59 benign, 46 malignant, 6 inflammatory, 4 non-inflammatory in 115 parotid mass, and 33 benign, 48 malgnant, 47 inflammatory, 6 non-inflammatory in 134 submandibular mass. One-hundred-eighty-six of entire 249 patients had tumor involvement, for a 74.7% incidence of neoplasia. There was a neoplastic predominance in parotid mass(91.3%) and a relative inflammatory predominance in submandibular mass(35.1%).

  • PDF

A Primary Neuroendocrine Tumor Mimicking a Thrombus in the Left Atrial Appendage (좌심방이에서 발생한 혈전을 모방한 심장의 일차성 신경 내분비 종양)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Dong Seop Jeong;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.444-449
    • /
    • 2022
  • Most cardiac tumors are metastases, and primary cardiac tumors are rare; even among primary cardiac tumors, primary cardiac neuroendocrine tumors (NETs) are extremely rare. Herein, we report a case of a patient presenting a left atrial mass without past medical history. Because of the location and movement of the mass, as well as the patient's cerebral infarction episode, the mass was initially suspected to be a thrombus. However, the mass was surgically diagnosed as NET.

Intraosseous Hemangioma of the Zygoma: A Case Report (광대뼈에 발생한 뼈내혈관종의 증례 보고)

  • Jeong, Minkyoung;Kwon, Yongseok;Jun, Dongkeun;Lee, Myungchul;Kim, Jeenam;Shin, Donghyeok;Kim, Wan-seop;Choi, Hyungon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.37 no.1
    • /
    • pp.33-37
    • /
    • 2021
  • Intraosseous hemangioma is a rare, benign vascular tumor of endothelial origin. It accounts for fewer than 1% of all hemangiomas, and very rarely occurs in the face. Intraosseous hemangioma usually presents as an asymptomatic lesion, but symptoms can occur due to the mass effect. The authors describe a case of intraosseous hemangioma of the zygoma with a review of the relevant literature. A 44-year-old man presented with a chief complaint of painless swelling on the left zygomatic region that had been slowly growing for the past year. On physical examination, a hard, non-movable mass in a deep layer was palpated. On computed tomography performed to evaluate its layers and extent, trabeculation was found inside the mass, but the lack of destruction of the surrounding bone suggested that the mass was benign. Complete surgical excision was performed under local anesthesia. After complete excision of the mass, slight erosions remained on the cortical bone of the zygoma, but because it was small enough not to cause a facial deformity such as depression or asymmetry, no additional reconstructive procedure was performed. There were no symptoms or recurrence during a 8-month follow-up period.

Comparison of Matrices for Optimal Analysis of Synthetic Polymers Using MALDI-TOF Mass Spectrometry

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Choi, Yoon-Ji;Choi, Jung Hoon;Park, Moonhee;Shin, DongJin;Oh, YoonSeok;Kim, YangSun;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.77-81
    • /
    • 2020
  • Characterization of the various chemical aspects of composite polymers is important for quality control of manufactured polymers. In this study, we compared three suitable matrices (α cyano-4-hydroxycinnamic acid [CHCA], 2,5 dihydroxy benzoic acid [2,5-DHB], and dithranol), to characterize various synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Although the spectra obtained with the CHCA and 2,5-DHB matrices were generally good, in certain samples ghost peaks disappeared only when dithranol was used as the matrix. Furthermore, we examined the use of sodium trifluoroacetate (NaTFA) as an additive to reduce interference by metals and copolymers in the spectra. In conclusion, appropriate selection of a matrix, according to the characteristics of the polymer, and the use of additives to improve sensitivity are important considerations for polymer analysis and development.