• Title/Summary/Keyword: Center X-ray angle

Search Result 136, Processing Time 0.03 seconds

A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine (척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.425-431
    • /
    • 2019
  • The Study In order to obtain images of overlap of the two iron cores in the spinal cord simple x-ray scan after surgery of patients with ulcer lateral sclerosis and a fractured backbone, the researcher conducted a subjective evaluation on five radiographers of the university hospital's imaging department for more than 10 years. The results of the experiment showed that the lateral shot of lateral scoliosis of the spinal cord was taken with the middle face of the IR plane, and then the X-ray tube angle was taken vertically with the vertical spinal column fan-tom position, resulting in two overlapping images and high scores in the subjective evaluation. In addition, lateral shots of the lumbar dislocation fractured lumbar vertebrae were taken with the forehead aligned with the center of the IR plane and then with the X-ray angle perpendicular to the fourth waistline and the angle of the spinal cord perpendicular to the fourth waistline, the image of the two iron cores could be obtained from the radiographer.

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

MICROSTRUCTURAL STUDY OF $Fe_{1-x}Ti_x$ ALLOYS FORMED BY ION BEAM MIXING

  • Jeon, Y.;Lee, Y.S.;Choi, B.S.;Woo, J.J.;Whang, C.N.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.127-132
    • /
    • 1997
  • Microstructure of the Fe-Ti system by ion beam mixing of multilayers at 300 K and 77 K has been studied in a wide composition range. The ion bombardment was carried out using $Ar^+$ ions at 80 keV. Using grazing angle x-ray diffraction we find that the lattice parameters of these bcc solid solutions are very close to that of $\alpha$-Fe. Extended x-ray absorption fine-structure spectroscopy have been performed to investgate the short-range order in the ion-beam-mixed state. The structure parameters, such as the interatomic distance and the coordination number are estmated from the Fe K-edge Fourier filtered EXAFS spectra. The interatomic distance is independent of the alloy concentration and it is almost constant. The study of x-ray absorption near-edge structure gives information on the individual $\rho$components of the partial densityof states of the conduction band of the Fe and Ti We also find that a charge transfer from Ti to Fe atoms takes place.

  • PDF

Study of Optimal Angle When Taking Foot AP Weight-Bearing Radiography (족부전후방향 체중부하 촬영 시 적정 입사각에 관한 연구)

  • Uhm, Min-Ji;Choi, Weon-Keun;Son, Soon-Yong;Lee, Kwan-Sup
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Incident X-ray angles of weight bearing foot AP radiography which differ in each medical institution were compared. Optimal angles were derived from the study and suggested as basic data for clinical application. 19 patients with no abnormality on right foot took part in the study from June 2013 to July 2013. Weight bearing foot AP radiography in the correct position was examined with the incident X-ray angles of $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, $30^{\circ}$, and $35^{\circ}$. All the images were evaluated subjectively by 5 radiological technologists of over 15 year work experience using Likert scale as 1 for 'very poor', 2 for 'poor', 3 for 'fair', 4 for 'good', 5 for 'very good', 6 for 'excellent', and analyzed with ANOVA and Scheffe. Image quality was the most optimal at $20^{\circ}$ as 4.53, and relatively good at $25^{\circ}$ as 4.38 and at $30^{\circ}$ as 4.18. $35^{\circ}$ and $10^{\circ}$ were relatively poor. The average points of 6 groups indicated statistically significant difference (p<.01). In the post-mortem, 3 subgroups showed no statistically significant difference, and the average point of the groups of $20^{\circ}$, $25^{\circ}$, $30^{\circ}$was evaluated relatively higher than the other 2 groups. An optimal incident X-ray angle within the range from $20^{\circ}$ to $30^{\circ}$ for weight bearing foot AP radiography could make it possible to obtain the image of high diagnostic value and would be useful for clinical application in the future.

  • PDF

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

Investingation on the Relationship Scoliotic Curve and BMI, Cervical Lordosis Lumar Lordosis and Ferguson Angle in Spinal Scoliosis Patient (척추측만증 환자의 척추만곡도에 관한 고찰)

  • Lee, Sang-Ho;Youn, You-Suk;Woo, In;Ha, In-Hyuck
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.1 no.2
    • /
    • pp.93-100
    • /
    • 2006
  • Objectives: To invesgate correlation between the scoliotic curve and BMI, cervical lordosis, lumbar lordosis and Ferguson angle in spinal scoliotic patient. Methods: The study was composed of 14 scoliosis patients beyond cobb'a angle $10^{\circ}$ (sample I group) and 15 scoliosis patients over cobb'a angle $10^{\circ}$ (sample II group). The patients were evaluated with X-ray findings of full spine AP and lateral views and statistically analyzed. Results: 1. Sample II group showed a significant decrease in BMI as compared with Sample I group(P<0.05). 2. Scoliotic curve had s negative relationship with $BMI({\gamma}=0.406)$ 3. Scolotic patients had a lower cervical angle than normal man. Conclusion: 1. The larger the scoliotic angle, the lower BMI 2. There are no concemed scoliotic curve and cervical lordosis, lumbar lordosis and Ferguson angle.

  • PDF

Structural Determination of cis- and trans-5-Hydroxymethyl-5-methyl-2-thiono-r-2-ethoxy-1,3,2-dioxaphosphorinane by NMR and X-ray Crystallography: Model Compounds for the Reaction Mechanism Study of Organophosphorus Pesticides

  • Kim, Jeong Han;Toia, Robert F.;Craig, Donald C.
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.37-43
    • /
    • 2000
  • 1,3,2-Dioxaphosphorinanes are suitable compounds for studying the stereochemistry of substitution at phosphorus. Cis- and trans-5-hydroxymethl-5-methyl-2-thiono-2ethoxy-1,3,2-dioxaphosphorinane were prepared, and their structures and stereochemistry unambiguously assigned by NMR and X-ray crystallography with acetoxy and 3,5-dinitrobenzoyloxy derivatives, respectively. Trans isomer gave $^{31}P$ NMR signal at higher field than cis isomer, and the ring proton Spectrum of cis isomer showed characteristic pattern for identifying its geometry. In X-ray crystallography they adopted a chair conformation with the ethoxy groups in the axial positions, and the sulfide groups in the equatorial positions. A flattening of the ring around the phosphorus center was noted, the POC bond angles were about $120^{\circ}$, and the C-O bonds in the ring were significantly longer than the C-O bond for the ethoxy group or the C-O bond for hydroxyl group.

  • PDF

Synthesis, Structure, and Thermal Property of Poly(trimethylene terephthalate- co-trimethylene 2,6-naphthalate) Copolymers

  • Jeong, Young-Gyu;Jo, Won-Ho;Lee, Sang-Cheol
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Poly(trimethylene terephthalate-co-trimethylene 2,6-naphthalate)s (P(TT-co-TN)s) with various copolymer composition were synthesized, and their chain structure, thermal property and crystalline structure were investigated by using $^1$H-NMR spectroscopy, differential scanning calorimetry (DSC) and wide-angle X-ray diffraction (WAXD), respectively. It was found from sequence analysis that all the P(TT-co-TN) copolymers synthesized have a statistical random distribution of TT and TN units. It was also observed from DSC thermograms that the glass transition temperature increases linearly with increasing the TN comonomer content, whereas the melting temperature of copolymer decreases with increasing the corresponding comonomer content in respective PTT- and PTN-based copolymer, showing pseudo-eutectic melting behavior. All the samples melt-crystallized isothermally except for P(TT-co-66 mol % TN) exhibit multiple melting endotherms and clear X-ray diffraction patterns. The multiple melting behavior originates from the dual lamellar population and/or the melting-recrystallization-remelting. The X-ray diffraction patterns are largely divided into two classes depending on the copolymer composition, i.e., PTT and PTN $\beta$-form diffraction patterns, without exhibiting cocrystallization.

Effect of RuO$_2$ Thin Film Microstructure on Characteristics of Thin Film Micro-supercapacitor ($RuO_2$박막의 미세 구조가 박막형 마이크로 슈퍼캐패시터의 특성에 미치는 영향)

  • Kim, Han-Ki;Yoon, Young-Soo;Lim, Jae-Hong;Cho, Won-Il;Seong, Tae-Yeon;Shin, Young-Hwa
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.671-678
    • /
    • 2001
  • All solid-state thin film micro supercapacitor, which consists of $RuO_2$/LiPON/$RuO_2$ multi layer structure, was fabricated on Pt/Ti/Si substrate using a $RuO_2$ electrode. Bottom $RuO_2$ electrode was grown by dc reactive sputtering system with increasing $O_2/[Ar+O_2]$ ratio at room temperature, and a LiPON electrolyte film was subsequently deposited on the bottom $RuO_2$ electrode at pure nitrogen ambient by rf reactive sputtering system. Room temperature charge-discharge measurements based on a symmetric $RuO_2$/LiPON/$RuO_2$ structure clearly demonstrates the cyclibility dependence on the microstructure of the $RuO_2$ electrode. Using both glancing angle x-ray diffraction (GXRD) and transmission electron microscopy (TEM) analysis, it was found that the microstructure of the $RuO_2$ electrode was dependent on the oxygen flow ratio. In addition, x- ray photoelectron spectroscopy(XPS) examination shows that the Ru-O binding energy is affected by increasing oxygen flow ratio. Furthermore, TEM and AES depth profile analysis after cycling demonstrates that the interface layer formed by interfacial reaction between LiPON and $RuO_2$ act as a main factor in the degradation of the cyclibility of the thin film micro-supercapacitor.

  • PDF

Sol-Gel Transition in Di-(2-ethylhexyl) phthalate-Plasticized Poly(vinyl chloride)

  • Lee, Chang-Hyung;Nah, Jae-Woon;Cho, Kil-Won;Kim, Seong-Hun;Hahn, Ai-Ran
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.10
    • /
    • pp.1485-1489
    • /
    • 2003
  • The gelation for di-(2-ethylhexyl) phthalate (DEHP)-plasticized poly(vinyl chloride) was studied by measuring time-resolved small-angle X-ray scattering (SAXS) and a flow of the solutions in test tube. It was found that for the gelation there were three regimes. At Regime I, the solution rapidly changed to a gel, and the SAXS intensity showed a peak and the peak intensity increased, keeping the peak angle constant. Applying the SAXS intensity to the kinetic analysis of the liquid-liquid phase separation, it was revealed that the spinodal decomposition proceeded to develop a periodic length of 29.9 nanometer in size, a hydrogen-bonding-type association in polymer rich phase followed, and then it induced fast gelation rate. At Regime II, the gelation slowly occurred and the SAXS intensity was not observed, suggesting that a homogeneous gel network was formed by a hydrogen-bonding. At regime III, the solution was a homogeneous sol.