• 제목/요약/키워드: Center Fire

검색결과 991건 처리시간 0.034초

Fire resistance and residual strength of reactive powder concrete Using metakaolin

  • Jang, Hongseok;Yi, Jebang;So, Seungyoung
    • Steel and Composite Structures
    • /
    • 재36권6호
    • /
    • pp.657-669
    • /
    • 2020
  • This study investigates the fire resistance characteristics of reactive powder concrete according to changes in the cement content per unit area, mixing ratio of metakaolin (MK), and content of polypropylene fiber. A fire test was conducted, and the resulting residual strength characteristics were investigated through flexural and compressive strength measurements, as well as condition rating classification based on visual evaluation. MK effectively reduced the initial high content of calcium hydroxide, thereby reducing the water vapor pressure generated during pyrolysis and slowing spalling. Furthermore, the pore structure and loose tissue were effective for relieving the water vapor pressure in the event of a fire.

울진지역 산불피해지의 산림피복형별 식생구조의 초기 변화 특성 (The Characteristics of Early Changes in Vegetation Structure by Forest Cover Type after Forest Fire Damage in Uljin region)

  • 김태운;한영섭;이성호;임채영;허태철;임창균;길민경;박준형
    • 한국환경복원기술학회지
    • /
    • 제27권3호
    • /
    • pp.1-18
    • /
    • 2024
  • The study aims to establish a direction for forest ecological restoration by classifying forest types and understanding the ecological characteristics of the Uljin forest area damaged by a large fire in 2022. Hierarchical cluster analysis and indicator species analysis were conducted on 78 survey plots located in the forest fire-affected area, and four forest cover types were derived: P. densiflora pure forests, P. densiflora dominant forests, mixed broad-leaved forests, and Q. variabilis dominant forests. As a result of visually comparing changes in forest types before and after forest fire damage, by classifying data according to whether or not upper dead trees are included, it was confirmed that pine forests, which have a high proportion of pine trees, spread widely due to forest fire damage. However, broad-leaved mixed forests and oyster oak dominant forests showed characteristics of maintaining concentration, indicating that pine forests were severely damaged. As a result of the important value analysis, during the process of natural recovery after a forest fire, the species that appear early in the lower layer are the sprouts of existing species such as Quercus mongolica Fisch. ex Ledeb., Quercus variabilis Blume, Fraxinus sieboldiana Blume, Rhododendron mucronulatum Turcz. The distribution of diameter at breast height by forest cover type showed that among areas with extreme forest fire damage, the proportion of dead trees was relatively high and structural changes were large in P. densiflora pure forests and P. densiflora dominant forests where pine trees had a high distribution ratio. However, if continuous monitoring is carried out in the future with reference to the results of this study and plant data is collected and analyzed from a mid- to long-term perspective, it is believed that it will be used as useful data to promote forest ecological restoration projects in forest fire-affected areas.

Feasibility and Acceptability of Workers' Health Surveillance for Fire Fighters

  • Plat, Marie-Christine J.;Frings-Dresen, Monique H.W.;Sluiter, Judith K.
    • Safety and Health at Work
    • /
    • 제2권3호
    • /
    • pp.218-228
    • /
    • 2011
  • Objectives: The objective of this study was to test the feasibility and acceptability of a new workers' health surveillance (WHS) for fire fighters in a Dutch pilot-implementation project. Methods: In three fire departments, between November 2007 and February 2009, feasibility was tested with respect to i) worker intent to change health and behavior; ii) the quality of instructions for testing teams; iii) the planned procedure in the field; and iv) future WHS organisation. Acceptability involved i) satisfaction with WHS and ii) verification of the job-specificity of the content of two physical tests of WHS. Fire fighters were surveyed after completing WHS, three testing teams were interviewed, and the content of the two tests was studied by experts. Results: Feasibility: nearly all of the 275 fire fighters intended to improve their health when recommended by the occupational physician. The testing teams found the instructions to be clear, and they were mostly positive about the organisation of WHS. Acceptability: the fire fighters rated WHS at eight points (out of a maximum of ten). The experts also reached a consensus about the optimal job-specific content of the future functional physical tests. Conclusion: Overall, it is feasible and acceptable to implement WHS in a definitive form in the Dutch fire-fighting sector.

터널 내 화재발생시 구난역 내의 연기 거동에 미치는 설계된 환기 영향에 대한 실험적 연구 (Experimental Study on the Designed Ventilation Effect on the Smoke Movement at Rescue Station fire in Railway Tunnel)

  • 김동운;이성혁;유홍선;윤성욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.163-167
    • /
    • 2008
  • In this study, the 1/35 reduced-scale model experiment were conducted to investigate designed ventilation effect on the smoke movement at rescue station fire in railway tunnel. A model tunnel with 2 mm thick, 10 m long, 0.19 m high and 0.26 m was made by using Froude number scaling law. The cross-passages installing escape door at the center were connected between incident tunnel and rescue tunnel. The n-heptane pool fires with heat release rate 698.97W were used as fire source. The fire source was located at the center and portal of incident tunnel as worst case. A operating ventilation system extracted smoke amount of 0.015 cms(cubic meters per second). The smoke temperature and CO gas concentration in cross-passage were measured to verify designed ventilation system. The result showed that, at center fire case without ventilation, smoke did not propagate to rescues station. In portal fire case, smoke spreaded to rescues station without ventilation. But smoke did not propagated to rescues station with designed ventilation.

  • PDF

소방대의 현장접근성 강화를 위한 설비의 개선방안 (The Way for improvement of facility to strengthen accessibility of the site for fire department)

  • 오택흠;성재만;박찬석
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

A Study on Fire Characteristics in a Tall and Narrow Atrium

  • Sugawa, Osami;Takahashi, Wataru;Ohtake, Masanori;Satoh, Hiroomi
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.353-360
    • /
    • 1997
  • The modeling on fire safety assessment for a tall and narrow atrium is carried out using a reduced and full scale atrium models based on the performances of flow behavior in and near comer fire and smoke ventilation system. The comer (or wall) effects on the flame behavior considering air entrainment into a flame was evaluated theoretically and experimentally. Temperature, upward velocity, inlet air velocity, and pressure difference between the atrium space and atmosphere were measured systematically in a reduced scale model. The performance of the modeling to estimate temperature rise and natural air ventilation volume was verified based on the experimental results. Smoke filling rate from a model fire source set at the center of a tall and narrow atrium is fastest in the other cases in which fire source set in or near a corner. This suggested that the centering of the fire source is acceptable as the fire source position to assess the fire safety design for a tall and narrow atrium.

  • PDF

할로우코어 슬래브의 내화성능에 대한 수치해석 연구 (Numerical Study on Fire Performance of Hollowcore Slabs)

  • 민정기;우영제
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.95-102
    • /
    • 2015
  • Numerical model on precast prestressed concrete (PC) hollowcore slabs using 11.3 mm diameter 7-wire stand was developed based on finite element analysis. In order to validate the modelling, previous experiment results with respect to prestressed solid concrete slabs were used and compared throughout the course of fire exposure. In addition to, the fire performance of hollowcore slabs with different aggregate types, moisture contents and compressive strength of concrete was investigated. As a result, it can be seen that the type of aggregates and moisture contents used in hollowcore slabs can affect the fire performance as well as temperature developments.

소방재원의 조달여건 및 조달방안에 대한 소방공무원의 인식에 관한 연구 (A Study on the Understanding of Fire Service Officers to the Procurement Circumstances and the Alternatives for Procuring Fire Service Funds)

  • 최낙순;안상봉
    • 한국화재소방학회논문지
    • /
    • 제21권2호
    • /
    • pp.87-97
    • /
    • 2007
  • 본 연구는 현행 소방재원의 조달여건의 문제점을 조명해보고 지방자치시대에 부응하는 주민의 소방수요에 안정적으로 대처할 수 있는 소방재원의 조달방안을 강구하고자 하는 목적을 갖고 이루어졌다. 분석결과는 다음과 같다. 대다수의 소방공무원들은 우리나라 소방재원의 조달여건이 아직 미성숙단계로 조달여건의 개선이 필요하다 인식하였으며, 소방본부 공무원들이 일선소방관서의 공무원들보다 부정적으로 인식하고 있는 것으로 나타났다. 또한 소방재원의 조달방안을 분석한 결과, 소방재원 조달시 추진계획에 있어서는 장기추진계획을 선호하였으며, 소방재원조달의 추진주체는 새롭게 신설된 소방방재청과 중앙정부가 가장 선호되었다. 재정제도의 개선방안으로는 현행 공동시설세를 현실화하고 운용방법을 개선하여야 한다는 의견이 가장 긍정적이었다. 구체적인 재원확보방안으로는 두집단 모두에서 공동시설세 세율을 인상하자는 의견이 가장 긍정적이었으며, 현행 재정 조정제도를 개편하여 소방재원을 확보하자는 의견과 소방병원 및 소방정비고를 신설하여 소방재원을 확보하자는 의견이 뒤를 이었다.

DPF 클리닝 직후에 주행 중 발생한 승용차화재 사례의 분석 (Analysis of an Automotive Fire Case that a Fire Broke out during Driving Immediately after DPF Cleaning)

  • 이의평
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.556-565
    • /
    • 2016
  • As a result of the enforced control of emission, many devices, including the diesel particulate filter, have been installed in diesel cars to reduce the emission of particulate matters. In this study, a car fire case has been investigated and analyzed. A car fire broke out after the vehicle traveled a distance of 1.4 km from a car service center. The car was provided with DPF cleaning when the DPF warning light came on. After being dismantled in the engine room, the car's engine and gearbox were investigated. The findings showed that the rear part of the DPF metal case was melted and punctured, while the honeycomb filter of the DPF was damaged. The car fire was caused by an overheated DPF associated with inaccurate maintenance practice. Therefore, the responsibility of the fire rested on the car service center that performed the DPF cleaning.

소방관의 우울, 불안, ADHD, 충동성 (Depression, Anxiety, ADHD, and Impulsivity with Fire Officers)

  • 신재권;김지선;임명호;이재원;김경민;이표규;오성범;양영애;백기청
    • 대한불안의학회지
    • /
    • 제13권2호
    • /
    • pp.93-99
    • /
    • 2017
  • Objective : This study aimed to evaluate the association of exhaustion, ADHD, self-esteem, impulsivity, suicidal tendencies and quality of life as well as depression and anxiety in fire officers in Korea. Methods : This study was undertaken for the first time in Korea, from September 2016 to December 2016. A set of questionnaires was provided to a total of 113 fire officers and 284 other participants as a comparison group. All subjects were evaluated using the Beck's Depression Inventory, Beck's Anxiety Inventory, Malach Burnout Inventory, Korean Adult Attention Deficit Hyperactivity Disorder Scales, Rosenberg's Self-esteem Inventory, Baratt's Impulsivity Scale, Beck's Scale of Suicide Ideation, and Quality of Life Scale. Furthermore, the odds ratio of depression, anxiety, exhaustion, ADHD, self-esteem, impulsivity, suicidal tendency and quality of life were evaluated the fire officer group and control group were compared through logistic regression analysis. Result : The results of this study indicated that the fire officers were more likely to show depression, anxiety, exhaustion, ADHD, low self-esteem and higher impulsivity. Also, the association between the fire officer group and depression, ADHD and impulsivity was confirmed through logistic regression analysis. Conclusion : Timely and effective evaluation and treatment of impulsivity, as well as depression is required for fire officers.